{"title":"开发和评估用于心动图解读的深度学习模型","authors":"Nicole Chiou, Nichole Young-Lin, Christopher Kelly, Tiya Tiyasirichokchai, Abdoulaye Diack, Sanmi Koyejo, Katherine Heller, Mercy Nyamewaa Asiedu","doi":"10.1101/2024.03.05.24303805","DOIUrl":null,"url":null,"abstract":"The inherent variability in the visual interpretation of cardiotocograms (CTGs) by obstetric clinical experts, both intra- and inter-observer, presents a substantial challenge in obstetric care. In response, we investigate automated CTG interpretation as a potential solution to enhance the early detection of fetal hypoxia during labor, which has the potential to reduce unnecessary operative interventions and improve overall maternal and neonatal care. This study employs deep learning techniques to reduce the subjectivity associated with visual CTG interpretation. Our results demonstrate that using objective umbilical cord blood pH outcome measurements, rather than clinician-defined Apgar scores, yields more consistent and robust model performance. Additionally, through a series of ablation studies, we explore the impact of temporal distribution shifts on the performance of these deep learning models. We examine tradeoffs between performance and fairness, specifically evaluating performance across demographic and clinical subgroups. Finally, we discuss the practical implications of our findings for the real-world deployment of such systems, emphasizing their potential utility in medical settings with limited resources.","PeriodicalId":501409,"journal":{"name":"medRxiv - Obstetrics and Gynecology","volume":"3 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and Evaluation of Deep Learning Models for Cardiotocography Interpretation\",\"authors\":\"Nicole Chiou, Nichole Young-Lin, Christopher Kelly, Tiya Tiyasirichokchai, Abdoulaye Diack, Sanmi Koyejo, Katherine Heller, Mercy Nyamewaa Asiedu\",\"doi\":\"10.1101/2024.03.05.24303805\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The inherent variability in the visual interpretation of cardiotocograms (CTGs) by obstetric clinical experts, both intra- and inter-observer, presents a substantial challenge in obstetric care. In response, we investigate automated CTG interpretation as a potential solution to enhance the early detection of fetal hypoxia during labor, which has the potential to reduce unnecessary operative interventions and improve overall maternal and neonatal care. This study employs deep learning techniques to reduce the subjectivity associated with visual CTG interpretation. Our results demonstrate that using objective umbilical cord blood pH outcome measurements, rather than clinician-defined Apgar scores, yields more consistent and robust model performance. Additionally, through a series of ablation studies, we explore the impact of temporal distribution shifts on the performance of these deep learning models. We examine tradeoffs between performance and fairness, specifically evaluating performance across demographic and clinical subgroups. Finally, we discuss the practical implications of our findings for the real-world deployment of such systems, emphasizing their potential utility in medical settings with limited resources.\",\"PeriodicalId\":501409,\"journal\":{\"name\":\"medRxiv - Obstetrics and Gynecology\",\"volume\":\"3 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"medRxiv - Obstetrics and Gynecology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1101/2024.03.05.24303805\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"medRxiv - Obstetrics and Gynecology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1101/2024.03.05.24303805","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and Evaluation of Deep Learning Models for Cardiotocography Interpretation
The inherent variability in the visual interpretation of cardiotocograms (CTGs) by obstetric clinical experts, both intra- and inter-observer, presents a substantial challenge in obstetric care. In response, we investigate automated CTG interpretation as a potential solution to enhance the early detection of fetal hypoxia during labor, which has the potential to reduce unnecessary operative interventions and improve overall maternal and neonatal care. This study employs deep learning techniques to reduce the subjectivity associated with visual CTG interpretation. Our results demonstrate that using objective umbilical cord blood pH outcome measurements, rather than clinician-defined Apgar scores, yields more consistent and robust model performance. Additionally, through a series of ablation studies, we explore the impact of temporal distribution shifts on the performance of these deep learning models. We examine tradeoffs between performance and fairness, specifically evaluating performance across demographic and clinical subgroups. Finally, we discuss the practical implications of our findings for the real-world deployment of such systems, emphasizing their potential utility in medical settings with limited resources.