一种高灵敏度的电化学传感探针,结合了经典的贝特洛反应和玻璃碳电极,用于测量水中超痕量的氨/NH4+含量

IF 4.7 3区 工程技术 Q2 ELECTROCHEMISTRY Electrochemistry Communications Pub Date : 2024-03-06 DOI:10.1016/j.elecom.2024.107686
H. Alwael , A.S. Alharthi , M.M. Dabi , M. Oubaha , M.S. El-Shahawi
{"title":"一种高灵敏度的电化学传感探针,结合了经典的贝特洛反应和玻璃碳电极,用于测量水中超痕量的氨/NH4+含量","authors":"H. Alwael ,&nbsp;A.S. Alharthi ,&nbsp;M.M. Dabi ,&nbsp;M. Oubaha ,&nbsp;M.S. El-Shahawi","doi":"10.1016/j.elecom.2024.107686","DOIUrl":null,"url":null,"abstract":"<div><p>In quantifying NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> ions, the wavelength-based spectrochemical methods involving formation of colored products of the Berthelot’s or Nessler reactions might be challenging due to auto-self absorbance, spectral overlap, and background scattering noise<strong>.</strong> Thus, the current study reports a renewable glassy carbon electrode (GCE) sensing probe combined with Berthelot’s reaction (indophenol formation) and adsorptive square - wave-anodic stripping voltammetry (Ads SWSV) at pH = 10 for detection of NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> in water. The redox characteristics and the high surface coverage of the oxidation product of indophenol on the sensing platform suggested its use for NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> detection. The electrochemical sensing probe for NH<sub>4</sub><sup>+</sup> displayed good linear relationship between 5.56 nM and 55.6 μM of NH<sub>4</sub><sup>+</sup> with limits of detection (LOD) and quantitation (LOQ) of 4.83 × 10<sup>-9</sup> and 1.47 × 10<sup>-8</sup> M, and sensing probe sensitivity of 1.27μA/μM<sup>−1</sup> cm<sup>−2</sup>,<!--> <!-->respectively. The probe was applied for measuring NH<sub>3</sub>/NH<sub>4</sub><sup>+</sup> <!-->in fresh and seawater samples, and the results were validated using standard ion chromatography (IC) and micro spectrophotometry assays. The assembled probe was also tolerably selective against interfering of other contaminants in a comparable potential window. Additionally, the probe has exceptional selectivity, long-term stability, and repeatability, and has good capacity to detect NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> ions with high accuracy (recovery range = 97.14 ± 4.12–102.9 ± 4.7) in environmental water samples. The calculated Student <em>t<sub>exp</sub></em> and <em>F<sub>exp</sub></em> values (n = 5) were less than the tabulated <em>t<sub>tab</sub></em> (2.78) and <em>F<sub>tab</sub></em> (6.39) at 95 % probability <em>(P</em> = 0.05, n = 5). The study offer high reliability towards NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> detection in complex environments.</p></div>","PeriodicalId":304,"journal":{"name":"Electrochemistry Communications","volume":"162 ","pages":"Article 107686"},"PeriodicalIF":4.7000,"publicationDate":"2024-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1388248124000298/pdfft?md5=6bd3d141796a46bc85f36176a08c9948&pid=1-s2.0-S1388248124000298-main.pdf","citationCount":"0","resultStr":"{\"title\":\"A highly sensitive electrochemical sensing probe incorporating classical Berthelot's reaction and glassy carbon electrode for measuring ultra-trace levels of ammonia/ NH4+ in water\",\"authors\":\"H. Alwael ,&nbsp;A.S. Alharthi ,&nbsp;M.M. Dabi ,&nbsp;M. Oubaha ,&nbsp;M.S. El-Shahawi\",\"doi\":\"10.1016/j.elecom.2024.107686\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In quantifying NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> ions, the wavelength-based spectrochemical methods involving formation of colored products of the Berthelot’s or Nessler reactions might be challenging due to auto-self absorbance, spectral overlap, and background scattering noise<strong>.</strong> Thus, the current study reports a renewable glassy carbon electrode (GCE) sensing probe combined with Berthelot’s reaction (indophenol formation) and adsorptive square - wave-anodic stripping voltammetry (Ads SWSV) at pH = 10 for detection of NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> in water. The redox characteristics and the high surface coverage of the oxidation product of indophenol on the sensing platform suggested its use for NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> detection. The electrochemical sensing probe for NH<sub>4</sub><sup>+</sup> displayed good linear relationship between 5.56 nM and 55.6 μM of NH<sub>4</sub><sup>+</sup> with limits of detection (LOD) and quantitation (LOQ) of 4.83 × 10<sup>-9</sup> and 1.47 × 10<sup>-8</sup> M, and sensing probe sensitivity of 1.27μA/μM<sup>−1</sup> cm<sup>−2</sup>,<!--> <!-->respectively. The probe was applied for measuring NH<sub>3</sub>/NH<sub>4</sub><sup>+</sup> <!-->in fresh and seawater samples, and the results were validated using standard ion chromatography (IC) and micro spectrophotometry assays. The assembled probe was also tolerably selective against interfering of other contaminants in a comparable potential window. Additionally, the probe has exceptional selectivity, long-term stability, and repeatability, and has good capacity to detect NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> ions with high accuracy (recovery range = 97.14 ± 4.12–102.9 ± 4.7) in environmental water samples. The calculated Student <em>t<sub>exp</sub></em> and <em>F<sub>exp</sub></em> values (n = 5) were less than the tabulated <em>t<sub>tab</sub></em> (2.78) and <em>F<sub>tab</sub></em> (6.39) at 95 % probability <em>(P</em> = 0.05, n = 5). The study offer high reliability towards NH<sub>3</sub> and/or NH<sub>4</sub><sup>+</sup> detection in complex environments.</p></div>\",\"PeriodicalId\":304,\"journal\":{\"name\":\"Electrochemistry Communications\",\"volume\":\"162 \",\"pages\":\"Article 107686\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2024-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1388248124000298/pdfft?md5=6bd3d141796a46bc85f36176a08c9948&pid=1-s2.0-S1388248124000298-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrochemistry Communications\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1388248124000298\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrochemistry Communications","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1388248124000298","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

摘要

在对 NH3 和/或 NH4+ 离子进行定量时,由于自吸、光谱重叠和背景散射噪声等原因,基于波长的光谱化学方法可能会因贝特洛反应或奈斯勒反应形成的有色产物而面临挑战。因此,本研究报告了一种可再生的玻璃碳电极(GCE)传感探针,它结合了贝氏反应(吲哚酚的形成)和吸附方波阳极剥离伏安法(ads SWSV),在 pH = 10 的条件下检测水中的 NH3 和/或 NH4+。吲哚苯酚氧化产物在传感平台上的氧化还原特性和高表面覆盖率表明它可用于检测 NH3 和/或 NH4+。该 NH4+ 电化学传感探针在 5.56 nM 和 55.6 μM 的 NH4+ 之间显示出良好的线性关系,检出限(LOD)和定量限(LOQ)分别为 4.83 × 10-9 M 和 1.47 × 10-8 M,传感探针灵敏度为 1.27μA/μM-1 cm-2。该探针被用于测量淡水和海水样品中的 NH3/NH4+,其结果通过标准离子色谱法(IC)和微分光光度法进行了验证。组装后的探针在可比电位窗口内对其他污染物的干扰也有一定的选择性。此外,该探针还具有优异的选择性、长期稳定性和可重复性,能够以较高的精度(回收率范围 = 97.14 ± 4.12-102.9 ± 4.7)检测环境水样中的 NH3 和/或 NH4+ 离子。计算得出的 Student texp 和 Fexp 值(n = 5)小于表格中的 ttab (2.78) 和 Ftab (6.39),概率为 95 % (P = 0.05, n = 5)。该研究为在复杂环境中检测 NH3 和/或 NH4+ 提供了高可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A highly sensitive electrochemical sensing probe incorporating classical Berthelot's reaction and glassy carbon electrode for measuring ultra-trace levels of ammonia/ NH4+ in water

In quantifying NH3 and/or NH4+ ions, the wavelength-based spectrochemical methods involving formation of colored products of the Berthelot’s or Nessler reactions might be challenging due to auto-self absorbance, spectral overlap, and background scattering noise. Thus, the current study reports a renewable glassy carbon electrode (GCE) sensing probe combined with Berthelot’s reaction (indophenol formation) and adsorptive square - wave-anodic stripping voltammetry (Ads SWSV) at pH = 10 for detection of NH3 and/or NH4+ in water. The redox characteristics and the high surface coverage of the oxidation product of indophenol on the sensing platform suggested its use for NH3 and/or NH4+ detection. The electrochemical sensing probe for NH4+ displayed good linear relationship between 5.56 nM and 55.6 μM of NH4+ with limits of detection (LOD) and quantitation (LOQ) of 4.83 × 10-9 and 1.47 × 10-8 M, and sensing probe sensitivity of 1.27μA/μM−1 cm−2, respectively. The probe was applied for measuring NH3/NH4+ in fresh and seawater samples, and the results were validated using standard ion chromatography (IC) and micro spectrophotometry assays. The assembled probe was also tolerably selective against interfering of other contaminants in a comparable potential window. Additionally, the probe has exceptional selectivity, long-term stability, and repeatability, and has good capacity to detect NH3 and/or NH4+ ions with high accuracy (recovery range = 97.14 ± 4.12–102.9 ± 4.7) in environmental water samples. The calculated Student texp and Fexp values (n = 5) were less than the tabulated ttab (2.78) and Ftab (6.39) at 95 % probability (P = 0.05, n = 5). The study offer high reliability towards NH3 and/or NH4+ detection in complex environments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electrochemistry Communications
Electrochemistry Communications 工程技术-电化学
CiteScore
8.50
自引率
3.70%
发文量
160
审稿时长
1.2 months
期刊介绍: Electrochemistry Communications is an open access journal providing fast dissemination of short communications, full communications and mini reviews covering the whole field of electrochemistry which merit urgent publication. Short communications are limited to a maximum of 20,000 characters (including spaces) while full communications and mini reviews are limited to 25,000 characters (including spaces). Supplementary information is permitted for full communications and mini reviews but not for short communications. We aim to be the fastest journal in electrochemistry for these types of papers.
期刊最新文献
Electrochemical detection of pesticides: A comprehensive review on voltammetric determination of malathion, 2,4-D, carbaryl, and glyphosate In-situ solvothermal synthesis of free-binder NiCo2S4/nickel foam electrode for supercapacitor application: Effects of CTAB surfactant Investigation of the modification of gold electrodes by electrochemical molecularly imprinted polymers as a selective layer for the trace level electroanalysis of PAH Corrosion of nickel foam electrodes during hydrothermal reactions: The influence of a simple protective carbon black coating Low-power and cost-effective readout circuit design for compact semiconductor gas sensor systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1