玻璃外壳真空电子管的寄生 X 射线发射:对职业剂量评估的影响》。

IF 2.5 3区 医学 Q2 BIOLOGY Radiation research Pub Date : 2024-05-01 DOI:10.1667/RADE-23-00161.1
H Pöttgen, A Schirmer, M Port, R Nusshardt
{"title":"玻璃外壳真空电子管的寄生 X 射线发射:对职业剂量评估的影响》。","authors":"H Pöttgen, A Schirmer, M Port, R Nusshardt","doi":"10.1667/RADE-23-00161.1","DOIUrl":null,"url":null,"abstract":"<p><p>Despite the large variety of high-voltage semiconductor components for medium and high voltage switching and pulse-forming applications as well as for high-power high-frequency generation, the use of vacuum electron tubes still prevails to a considerable degree. Due to the common design incorporating a high energy electron beam which finally is dumped into an anode or a resonator cavity, these tubes are also considered as sources of X rays produced as bremsstrahlung and characteristic radiation, which are referred to as parasitic X rays. Here three types of vacuum-electron tubes, diode, tetrode, and thyratron, with glass housings are investigated. They are predominantly operated in the high voltage range below 30 kV and are not subject to licensing laws. The measurements of the dose rate and X-ray-spectra were performed in the laboratory without complex electrical circuitry usually used in making practical measurements for occupational radiation protection. For the diode tube, where a parasitic X-ray emission is observed only in the reverse operation as a blocking diode, a broad distribution of dose rates of electrically equivalent specimens was observed. This is attributed to field emission from the electrodes. For the tetrode and the thyratron tubes, field emission from the electrodes is identified as the dominant mechanism for the generation of parasitic X rays. Thus, technical radiation protection must focus on shielding of the glass tube rather than optimization of the electrical circuitry.</p>","PeriodicalId":20903,"journal":{"name":"Radiation research","volume":" ","pages":"499-503"},"PeriodicalIF":2.5000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Emission of Parasitic X Rays of Vacuum-electron Tubes with Glass Housings: Implications for the Evaluation of Occupational Doses.\",\"authors\":\"H Pöttgen, A Schirmer, M Port, R Nusshardt\",\"doi\":\"10.1667/RADE-23-00161.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Despite the large variety of high-voltage semiconductor components for medium and high voltage switching and pulse-forming applications as well as for high-power high-frequency generation, the use of vacuum electron tubes still prevails to a considerable degree. Due to the common design incorporating a high energy electron beam which finally is dumped into an anode or a resonator cavity, these tubes are also considered as sources of X rays produced as bremsstrahlung and characteristic radiation, which are referred to as parasitic X rays. Here three types of vacuum-electron tubes, diode, tetrode, and thyratron, with glass housings are investigated. They are predominantly operated in the high voltage range below 30 kV and are not subject to licensing laws. The measurements of the dose rate and X-ray-spectra were performed in the laboratory without complex electrical circuitry usually used in making practical measurements for occupational radiation protection. For the diode tube, where a parasitic X-ray emission is observed only in the reverse operation as a blocking diode, a broad distribution of dose rates of electrically equivalent specimens was observed. This is attributed to field emission from the electrodes. For the tetrode and the thyratron tubes, field emission from the electrodes is identified as the dominant mechanism for the generation of parasitic X rays. Thus, technical radiation protection must focus on shielding of the glass tube rather than optimization of the electrical circuitry.</p>\",\"PeriodicalId\":20903,\"journal\":{\"name\":\"Radiation research\",\"volume\":\" \",\"pages\":\"499-503\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1667/RADE-23-00161.1\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1667/RADE-23-00161.1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

尽管用于中压和高压开关、脉冲形成以及大功率高频发电的高压半导体元件种类繁多,但真空电子管的使用在很大程度上仍然占主导地位。由于这些真空电子管的常见设计是将高能电子束最终倾入阳极或谐振腔,因此也被认为是产生轫致辐射和特征辐射的 X 射线的来源,这些辐射被称为寄生 X 射线。这里研究的是三种带有玻璃外壳的真空电子管,即二极管、四极管和三极管。它们主要在 30 千伏以下的高压范围内运行,不受许可法的限制。剂量率和 X 射线频谱的测量是在实验室进行的,没有通常用于职业辐射防护实际测量的复杂电路。对于二极管管来说,只有在作为阻断二极管反向工作时才会出现寄生 X 射线发射,因此可以观察到电气等效试样剂量率的广泛分布。这归因于电极的场发射。对于四极管和三极管,电极的场发射被认为是产生寄生 X 射线的主要机制。因此,技术辐射防护必须侧重于玻璃管的屏蔽,而不是电路的优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Emission of Parasitic X Rays of Vacuum-electron Tubes with Glass Housings: Implications for the Evaluation of Occupational Doses.

Despite the large variety of high-voltage semiconductor components for medium and high voltage switching and pulse-forming applications as well as for high-power high-frequency generation, the use of vacuum electron tubes still prevails to a considerable degree. Due to the common design incorporating a high energy electron beam which finally is dumped into an anode or a resonator cavity, these tubes are also considered as sources of X rays produced as bremsstrahlung and characteristic radiation, which are referred to as parasitic X rays. Here three types of vacuum-electron tubes, diode, tetrode, and thyratron, with glass housings are investigated. They are predominantly operated in the high voltage range below 30 kV and are not subject to licensing laws. The measurements of the dose rate and X-ray-spectra were performed in the laboratory without complex electrical circuitry usually used in making practical measurements for occupational radiation protection. For the diode tube, where a parasitic X-ray emission is observed only in the reverse operation as a blocking diode, a broad distribution of dose rates of electrically equivalent specimens was observed. This is attributed to field emission from the electrodes. For the tetrode and the thyratron tubes, field emission from the electrodes is identified as the dominant mechanism for the generation of parasitic X rays. Thus, technical radiation protection must focus on shielding of the glass tube rather than optimization of the electrical circuitry.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation research
Radiation research 医学-核医学
CiteScore
5.10
自引率
8.80%
发文量
179
审稿时长
1 months
期刊介绍: Radiation Research publishes original articles dealing with radiation effects and related subjects in the areas of physics, chemistry, biology and medicine, including epidemiology and translational research. The term radiation is used in its broadest sense and includes specifically ionizing radiation and ultraviolet, visible and infrared light as well as microwaves, ultrasound and heat. Effects may be physical, chemical or biological. Related subjects include (but are not limited to) dosimetry methods and instrumentation, isotope techniques and studies with chemical agents contributing to the understanding of radiation effects.
期刊最新文献
Effect of Ultrahigh Dose Rate on Biomolecular Radiation Damage. A Million Person Study Innovation: Evaluating Cognitive Impairment and other Morbidity Outcomes from Chronic Radiation Exposure Through Linkages with the Centers for Medicaid and Medicare Services Assessment and Claims Data. Hepatic Stellate Cell-mediated Increase in CCL5 Chemokine Expression after X-ray Irradiation Determined In Vitro and In Vivo. Response of Spontaneous Oral Tumors in Canine Cancer Patients Treated with Stereotactic Body Radiation Therapy (SBRT). Survey of Changes in Absolute Lymphocyte Counts and Peripheral Immune Repertoire Diversity after External Beam Radiotherapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1