Zheqing Zhou, Siyu Wang, Quan Yuan, Li Yue, Shengtao Yang
{"title":"评估全数字化髁状突矢状倾角测量方法的准确性。","authors":"Zheqing Zhou, Siyu Wang, Quan Yuan, Li Yue, Shengtao Yang","doi":"10.7518/hxkq.2024.2023242","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This clinical study aimed to evaluate the accuracy of a fully digital technique for measuring sagittal condylar inclination (SCI), as well as validating whether differences existed between the left and right SCI values of the same participant, to provide a reference for clinical practice.</p><p><strong>Methods: </strong>Ten participants with good occlusal relationship and normal temporomandibular joint were recruited. Three methods were used to measure the SCI values of the participants, namely, A (mechanical facebow transferring and mechanical articulator-based measuring method with physical protrusive interocclusal registration), B (face scan-based virtual facebow and virtual articulator-based measuring method with digital protrusive interocclusal registration), and C (jaw motion tracking system-based measuring method). With the group subjected to methods A and C as the control, the SCI values obtained by the three methods were statistically analyzed. The left and right SCI values of the same participant were also compared.</p><p><strong>Results: </strong>The left and right SCI values measured by method A were 41.70°±7.09° and 42.80°±8.62°, those by method B were 35.09°±12.49° and 37.63°±12.10°, and those by method C were 39.43°±8.72° and 38.45°±6.91°. No significant difference existed among the SCI values measured by the three methods (<i>P</i>>0.05). Meanwhile, no statistical difference existed between the SCI values on the left and right sides of the same participant (<i>P</i>>0.05).</p><p><strong>Conclusions: </strong>The accuracy of the virtual facebow and digital protrusive occlusal registration based SCI measuring method was the same as that of mechanical facebow based and jaw motion tracking system-based methods. The SCI values on the left and right sides of the same participant were similar. Clinically, an appropriate SCI measurement and setting strategy can be selected based on the actual situations.</p>","PeriodicalId":94028,"journal":{"name":"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology","volume":"42 1","pages":"67-74"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10965349/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the accuracy of a fully digital method of measuring sagittal condylar inclination.\",\"authors\":\"Zheqing Zhou, Siyu Wang, Quan Yuan, Li Yue, Shengtao Yang\",\"doi\":\"10.7518/hxkq.2024.2023242\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This clinical study aimed to evaluate the accuracy of a fully digital technique for measuring sagittal condylar inclination (SCI), as well as validating whether differences existed between the left and right SCI values of the same participant, to provide a reference for clinical practice.</p><p><strong>Methods: </strong>Ten participants with good occlusal relationship and normal temporomandibular joint were recruited. Three methods were used to measure the SCI values of the participants, namely, A (mechanical facebow transferring and mechanical articulator-based measuring method with physical protrusive interocclusal registration), B (face scan-based virtual facebow and virtual articulator-based measuring method with digital protrusive interocclusal registration), and C (jaw motion tracking system-based measuring method). With the group subjected to methods A and C as the control, the SCI values obtained by the three methods were statistically analyzed. The left and right SCI values of the same participant were also compared.</p><p><strong>Results: </strong>The left and right SCI values measured by method A were 41.70°±7.09° and 42.80°±8.62°, those by method B were 35.09°±12.49° and 37.63°±12.10°, and those by method C were 39.43°±8.72° and 38.45°±6.91°. No significant difference existed among the SCI values measured by the three methods (<i>P</i>>0.05). Meanwhile, no statistical difference existed between the SCI values on the left and right sides of the same participant (<i>P</i>>0.05).</p><p><strong>Conclusions: </strong>The accuracy of the virtual facebow and digital protrusive occlusal registration based SCI measuring method was the same as that of mechanical facebow based and jaw motion tracking system-based methods. The SCI values on the left and right sides of the same participant were similar. Clinically, an appropriate SCI measurement and setting strategy can be selected based on the actual situations.</p>\",\"PeriodicalId\":94028,\"journal\":{\"name\":\"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology\",\"volume\":\"42 1\",\"pages\":\"67-74\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10965349/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7518/hxkq.2024.2023242\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7518/hxkq.2024.2023242","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
研究目的本临床研究旨在评估全数字化技术测量矢状髁状突倾角(SCI)的准确性,并验证同一受试者的左右SCI值是否存在差异,为临床实践提供参考:方法:招募 10 名咬合关系良好、颞下颌关节正常的参与者。采用三种方法测量受试者的 SCI 值,分别是 A(基于机械面弓传输和机械关节器的测量方法,并进行物理突触咬合间登记)、B(基于面部扫描的虚拟面弓和虚拟关节器的测量方法,并进行数字突触咬合间登记)和 C(基于下颌运动跟踪系统的测量方法)。以采用 A 和 C 方法的组为对照,对三种方法获得的 SCI 值进行统计分析。同时还比较了同一受试者的左右 SCI 值:结果:采用 A 方法测量的左右 SCI 值分别为 41.70°±7.09°和 42.80°±8.62°,采用 B 方法测量的左右 SCI 值分别为 35.09°±12.49°和 37.63°±12.10°,采用 C 方法测量的左右 SCI 值分别为 39.43°±8.72°和 38.45°±6.91°。三种方法测得的 SCI 值无明显差异(P>0.05)。同时,同一受试者左右两侧的 SCI 值无统计学差异(P>0.05):基于虚拟面弓和数字突出咬合登记的 SCI 测量方法与基于机械面弓和下颌运动跟踪系统的测量方法的准确性相同。同一受试者左右两侧的 SCI 值相似。临床上,可根据实际情况选择合适的 SCI 测量和设置策略。
Evaluation of the accuracy of a fully digital method of measuring sagittal condylar inclination.
Objectives: This clinical study aimed to evaluate the accuracy of a fully digital technique for measuring sagittal condylar inclination (SCI), as well as validating whether differences existed between the left and right SCI values of the same participant, to provide a reference for clinical practice.
Methods: Ten participants with good occlusal relationship and normal temporomandibular joint were recruited. Three methods were used to measure the SCI values of the participants, namely, A (mechanical facebow transferring and mechanical articulator-based measuring method with physical protrusive interocclusal registration), B (face scan-based virtual facebow and virtual articulator-based measuring method with digital protrusive interocclusal registration), and C (jaw motion tracking system-based measuring method). With the group subjected to methods A and C as the control, the SCI values obtained by the three methods were statistically analyzed. The left and right SCI values of the same participant were also compared.
Results: The left and right SCI values measured by method A were 41.70°±7.09° and 42.80°±8.62°, those by method B were 35.09°±12.49° and 37.63°±12.10°, and those by method C were 39.43°±8.72° and 38.45°±6.91°. No significant difference existed among the SCI values measured by the three methods (P>0.05). Meanwhile, no statistical difference existed between the SCI values on the left and right sides of the same participant (P>0.05).
Conclusions: The accuracy of the virtual facebow and digital protrusive occlusal registration based SCI measuring method was the same as that of mechanical facebow based and jaw motion tracking system-based methods. The SCI values on the left and right sides of the same participant were similar. Clinically, an appropriate SCI measurement and setting strategy can be selected based on the actual situations.