评估在无牙下颌植入不同数量种植体的种植覆盖义齿的咀嚼效率和 OHRQoL:一项为期一年的前瞻性随访研究。

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2024-03-14 DOI:10.1186/s40729-024-00519-0
Kawe Sagheb, Stefan Wentaschek, Monika Bjelopavlovic, Manfred Berres, Leonardo Díaz, Shengchi Fan, Eik Schiegnitz, Bilal Al-Nawas, Keyvan Sagheb
{"title":"评估在无牙下颌植入不同数量种植体的种植覆盖义齿的咀嚼效率和 OHRQoL:一项为期一年的前瞻性随访研究。","authors":"Kawe Sagheb, Stefan Wentaschek, Monika Bjelopavlovic, Manfred Berres, Leonardo Díaz, Shengchi Fan, Eik Schiegnitz, Bilal Al-Nawas, Keyvan Sagheb","doi":"10.1186/s40729-024-00519-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible.</p><p><strong>Methods: </strong>From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up.</p><p><strong>Result: </strong>A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22).</p><p><strong>Conclusions: </strong>A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"10 1","pages":"12"},"PeriodicalIF":3.1000,"publicationDate":"2024-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10937875/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of masticatory efficiency and OHRQoL in implant-retained overdenture with different numbers of implant in the edentulous mandible: a one-year follow-up prospective study.\",\"authors\":\"Kawe Sagheb, Stefan Wentaschek, Monika Bjelopavlovic, Manfred Berres, Leonardo Díaz, Shengchi Fan, Eik Schiegnitz, Bilal Al-Nawas, Keyvan Sagheb\",\"doi\":\"10.1186/s40729-024-00519-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible.</p><p><strong>Methods: </strong>From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up.</p><p><strong>Result: </strong>A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22).</p><p><strong>Conclusions: </strong>A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.</p>\",\"PeriodicalId\":14076,\"journal\":{\"name\":\"International Journal of Implant Dentistry\",\"volume\":\"10 1\",\"pages\":\"12\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10937875/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Implant Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40729-024-00519-0\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-024-00519-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本文旨在评估种植体固位覆盖义齿的咀嚼功能表现和与口腔健康相关的生活质量(OHRQoL),并与在无牙颌中植入不同数量的种植体进行比较:从 2013 年到 2015 年,每位患者在下颌骨(34、41/31、44)孔内植入 3 个种植体(iSy-Implant,Camlog,Wimsheim,Germany)。手术后,植入的种植体在 3+3+3 个月内逐渐加载并与带有自动对齐连接系统(Locator 基台)的覆盖义齿结合。使用多色口香糖进行了咀嚼周期测试,并进行了 OHIP-G14 问卷调查和总分问卷调查,共分为五个检查点:手术前、植入一颗种植体(41/31)、植入两颗种植体(33,43)、植入三颗种植体和一年随访:结果:共为 10 位患者植入了 30 个种植体,随访 1 年的种植体存活率为 100%。咀嚼功能分析显示,咀嚼次数越多,混合率越高。一年后,与三个种植体植入连接系统后相比,混合率没有明显变化。术前 OHIP-G14 的平均值为 30.4,装入第一个定位基台后为 21.1,装入两个定位基台后为 10.7,装入所有三个定位基台后为 3.2。一年后,OHIP-G14 为 2.6,无明显变化。术前总分的平均值为 15.5,激活第一个定位器后为 27.8,激活两个定位器后为 39.4,激活所有三个定位器后为 46.2,1 年后为 47.3。每个时间点的总分增加了 0.7 个单位。与OHIP-G14类似,与激活所有三个定位器的时间相比,没有发现显著性差异(P值=0.22):结论:随着下颌无牙颌种植体与定位器连接数量的增加,咀嚼功能和 OHRQoL 均有明显改善。通过对 OHIP-G14 和总分的调查,患者报告结果可能与种植体数量的增加有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of masticatory efficiency and OHRQoL in implant-retained overdenture with different numbers of implant in the edentulous mandible: a one-year follow-up prospective study.

Purpose: The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible.

Methods: From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up.

Result: A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22).

Conclusions: A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
In-vitro investigation of bone temperature changes in osteotomies performed with different brands of implant burs. A digital way to assess the stain parameters that lead to soft tissue blanching when delivering an implant-supported crown. Electroplated double-crowns on implants and teeth after up to 12 years- a retrospective clinical study. The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10-year follow-up and literature review. Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1