Sam Rodgers, Timothy Woolley, Joshua Smith, Peter Prinsloo, Natasha Fernando
{"title":"最新成人铁蛋白参考区间,基于英国大量健康样本,使用罗氏 Cobas 系列分析仪进行测量。","authors":"Sam Rodgers, Timothy Woolley, Joshua Smith, Peter Prinsloo, Natasha Fernando","doi":"10.1177/00045632241243026","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is a lack of standardization of reference intervals (RIs) for ferritin across laboratories, particularly for postmenopausal women. Depending on the RI used, there can be more than a 4-fold difference in the upper limit of normal between laboratories, resulting in potential misinterpretation.</p><p><strong>Methods: </strong>This retrospective study used a large dataset of blood test results from 25,425 healthy participants aged 18 to 97 over a 7-year period. Exclusion criteria were used to screen out individuals with conditions known to affect iron metabolism or raise ferritin as part of the acute phase response. Distributions were assessed using density and Q-Q plots, and age-banded cut-offs were determined. The non-parametric method was used to establish RIs for sex and age bands.</p><p><strong>Results: </strong>For females, 4 age bands were established (18-39, 40-49, 50-59 and 60+). For males, 2 bands were identified (18-39 and 40+). Performance against a validation dataset, followed by an expansive validation against an inclusive dataset, demonstrated the robustness of the derived RIs.</p><p><strong>Conclusion: </strong>This study addresses the inconsistency in serum ferritin RIs by presenting intervals based on demographic parameters. This approach can potentially enhance the accuracy of interpreting serum ferritin levels, assisting clinicians in identifying patients requiring further evaluation.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"365-371"},"PeriodicalIF":2.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Updated adult ferritin reference intervals based on a large, healthy UK sample, measured on Roche Cobas series analysers.\",\"authors\":\"Sam Rodgers, Timothy Woolley, Joshua Smith, Peter Prinsloo, Natasha Fernando\",\"doi\":\"10.1177/00045632241243026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There is a lack of standardization of reference intervals (RIs) for ferritin across laboratories, particularly for postmenopausal women. Depending on the RI used, there can be more than a 4-fold difference in the upper limit of normal between laboratories, resulting in potential misinterpretation.</p><p><strong>Methods: </strong>This retrospective study used a large dataset of blood test results from 25,425 healthy participants aged 18 to 97 over a 7-year period. Exclusion criteria were used to screen out individuals with conditions known to affect iron metabolism or raise ferritin as part of the acute phase response. Distributions were assessed using density and Q-Q plots, and age-banded cut-offs were determined. The non-parametric method was used to establish RIs for sex and age bands.</p><p><strong>Results: </strong>For females, 4 age bands were established (18-39, 40-49, 50-59 and 60+). For males, 2 bands were identified (18-39 and 40+). Performance against a validation dataset, followed by an expansive validation against an inclusive dataset, demonstrated the robustness of the derived RIs.</p><p><strong>Conclusion: </strong>This study addresses the inconsistency in serum ferritin RIs by presenting intervals based on demographic parameters. This approach can potentially enhance the accuracy of interpreting serum ferritin levels, assisting clinicians in identifying patients requiring further evaluation.</p>\",\"PeriodicalId\":8005,\"journal\":{\"name\":\"Annals of Clinical Biochemistry\",\"volume\":\" \",\"pages\":\"365-371\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Clinical Biochemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00045632241243026\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632241243026","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Updated adult ferritin reference intervals based on a large, healthy UK sample, measured on Roche Cobas series analysers.
Background: There is a lack of standardization of reference intervals (RIs) for ferritin across laboratories, particularly for postmenopausal women. Depending on the RI used, there can be more than a 4-fold difference in the upper limit of normal between laboratories, resulting in potential misinterpretation.
Methods: This retrospective study used a large dataset of blood test results from 25,425 healthy participants aged 18 to 97 over a 7-year period. Exclusion criteria were used to screen out individuals with conditions known to affect iron metabolism or raise ferritin as part of the acute phase response. Distributions were assessed using density and Q-Q plots, and age-banded cut-offs were determined. The non-parametric method was used to establish RIs for sex and age bands.
Results: For females, 4 age bands were established (18-39, 40-49, 50-59 and 60+). For males, 2 bands were identified (18-39 and 40+). Performance against a validation dataset, followed by an expansive validation against an inclusive dataset, demonstrated the robustness of the derived RIs.
Conclusion: This study addresses the inconsistency in serum ferritin RIs by presenting intervals based on demographic parameters. This approach can potentially enhance the accuracy of interpreting serum ferritin levels, assisting clinicians in identifying patients requiring further evaluation.
期刊介绍:
Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine.
Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals.
Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).