腿部动脉穿孔热成像图

Izegaegbe O Obadan, Afieharo I Michael, Ayodele O Iyun, Samuel A Ademola, Olayinka A Olawoye, Rotimi O Aderibigbe, Odunayo M Oluwatosin
{"title":"腿部动脉穿孔热成像图","authors":"Izegaegbe O Obadan, Afieharo I Michael, Ayodele O Iyun, Samuel A Ademola, Olayinka A Olawoye, Rotimi O Aderibigbe, Odunayo M Oluwatosin","doi":"10.4103/jwas.jwas_84_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Preoperative localisation of perforators aids in easy intraoperative dissection. Infrared thermography is a simple, safe, and effective tool with a short learning curve that is useful in identifying perforators. It has been found to have a high concordance rate when compared with computed tomography angiography and is useful in identifying arterial perforators in the leg.</p><p><strong>Objectives: </strong>To create a thermographic map of arterial perforators in the leg and to determine the correlation between the number of perforators identified and the length of the leg.</p><p><strong>Materials and methods: </strong>This was a cross-sectional study. The length of the leg was measured and the location of perforators corresponding to the distribution of the anterior tibial, posterior tibial, and peroneal arteries was identified using thermography. The mean number of perforators corresponding to the different surfaces of the leg was noted, this was then correlated with the length of the leg using the Pearson correlation coefficient.</p><p><strong>Results: </strong>Using thermography, perforators were identified along a line drawn from the medial malleolus to the medial tibia plateau and from the lateral malleolus to the head of the fibula and within 2 cm of these lines. More perforators were found in the middle third of the leg and there was no significant correlation between the number of perforators and the length of the leg.</p><p><strong>Conclusion: </strong>A useful surface marking to aid the identification of perforators in the leg using infrared thermography was found. There was no significant correlation between the length of the leg and the number of perforators.</p>","PeriodicalId":73993,"journal":{"name":"Journal of the West African College of Surgeons","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10936892/pdf/","citationCount":"0","resultStr":"{\"title\":\"Thermographic Mapping of Arterial Perforators in the Leg.\",\"authors\":\"Izegaegbe O Obadan, Afieharo I Michael, Ayodele O Iyun, Samuel A Ademola, Olayinka A Olawoye, Rotimi O Aderibigbe, Odunayo M Oluwatosin\",\"doi\":\"10.4103/jwas.jwas_84_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Preoperative localisation of perforators aids in easy intraoperative dissection. Infrared thermography is a simple, safe, and effective tool with a short learning curve that is useful in identifying perforators. It has been found to have a high concordance rate when compared with computed tomography angiography and is useful in identifying arterial perforators in the leg.</p><p><strong>Objectives: </strong>To create a thermographic map of arterial perforators in the leg and to determine the correlation between the number of perforators identified and the length of the leg.</p><p><strong>Materials and methods: </strong>This was a cross-sectional study. The length of the leg was measured and the location of perforators corresponding to the distribution of the anterior tibial, posterior tibial, and peroneal arteries was identified using thermography. The mean number of perforators corresponding to the different surfaces of the leg was noted, this was then correlated with the length of the leg using the Pearson correlation coefficient.</p><p><strong>Results: </strong>Using thermography, perforators were identified along a line drawn from the medial malleolus to the medial tibia plateau and from the lateral malleolus to the head of the fibula and within 2 cm of these lines. More perforators were found in the middle third of the leg and there was no significant correlation between the number of perforators and the length of the leg.</p><p><strong>Conclusion: </strong>A useful surface marking to aid the identification of perforators in the leg using infrared thermography was found. There was no significant correlation between the length of the leg and the number of perforators.</p>\",\"PeriodicalId\":73993,\"journal\":{\"name\":\"Journal of the West African College of Surgeons\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10936892/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the West African College of Surgeons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jwas.jwas_84_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the West African College of Surgeons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jwas.jwas_84_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/14 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:术前定位穿孔有助于术中轻松解剖。红外热成像是一种简单、安全、有效的工具,学习曲线短,有助于识别穿孔器。与计算机断层扫描血管造影术相比,红外热成像技术具有较高的吻合率,有助于识别腿部动脉穿孔器:绘制腿部动脉穿孔热成像图,并确定穿孔数量与腿部长度之间的相关性:这是一项横断面研究。测量腿的长度,并使用热成像技术确定与胫前动脉、胫后动脉和腓动脉分布相对应的穿孔器位置。记录腿部不同表面穿孔器的平均数量,然后用皮尔逊相关系数将其与腿长相关联:利用热成像技术,沿着从内侧踝骨到胫骨内侧平台、从外侧踝骨到腓骨头的一条线以及在这些线的 2 厘米范围内发现了穿孔器。在腿的中间三分之一处发现了更多的穿孔器,穿孔器的数量与腿的长度之间没有明显的相关性:结论:利用红外热成像技术识别腿部穿孔器的表面标记非常有用。腿的长度与穿孔器的数量之间没有明显的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermographic Mapping of Arterial Perforators in the Leg.

Background: Preoperative localisation of perforators aids in easy intraoperative dissection. Infrared thermography is a simple, safe, and effective tool with a short learning curve that is useful in identifying perforators. It has been found to have a high concordance rate when compared with computed tomography angiography and is useful in identifying arterial perforators in the leg.

Objectives: To create a thermographic map of arterial perforators in the leg and to determine the correlation between the number of perforators identified and the length of the leg.

Materials and methods: This was a cross-sectional study. The length of the leg was measured and the location of perforators corresponding to the distribution of the anterior tibial, posterior tibial, and peroneal arteries was identified using thermography. The mean number of perforators corresponding to the different surfaces of the leg was noted, this was then correlated with the length of the leg using the Pearson correlation coefficient.

Results: Using thermography, perforators were identified along a line drawn from the medial malleolus to the medial tibia plateau and from the lateral malleolus to the head of the fibula and within 2 cm of these lines. More perforators were found in the middle third of the leg and there was no significant correlation between the number of perforators and the length of the leg.

Conclusion: A useful surface marking to aid the identification of perforators in the leg using infrared thermography was found. There was no significant correlation between the length of the leg and the number of perforators.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
"Weighing it Down": Technique to Reduce the Weight of an Obturator. A Prospective Study on Tibial Shaft Fractures Treated with Suprapatellar Approach. An Unusual Presentation of Intestinal Obstruction: Uterine Perforation and Bowel Herniation Following Manual Vacuum Aspiration. Assessment of the Effects of the COVID-19 Pandemic on Orthopaedic Surgery Training Among Orthopaedic Residents in Southern Nigeria. Computed Tomographic Scan for Head Injury Patients: Any Justification for Adapting Routine Cranio-Cervical Examination Irrespective of Clinical Severity?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1