比较预制钛基台和个性化混合氧化锆基台用于粘结氧化锆固定义齿的横截面分析:关键概念评估

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2024-03-18 DOI:10.1186/s40729-024-00529-y
Norbert Neckel, Josephine Pohl, Saskia Preissner, Oliver Wagendorf, Claudia Sachse, Kirstin Vach, Max Heiland, Susanne Nahles
{"title":"比较预制钛基台和个性化混合氧化锆基台用于粘结氧化锆固定义齿的横截面分析:关键概念评估","authors":"Norbert Neckel, Josephine Pohl, Saskia Preissner, Oliver Wagendorf, Claudia Sachse, Kirstin Vach, Max Heiland, Susanne Nahles","doi":"10.1186/s40729-024-00529-y","DOIUrl":null,"url":null,"abstract":"Despite the differences in material properties and shapes among the different types of prefabricated titanium (pTiA) and individualized hybrid zirconia abutments (ihZiA), the biological and clinical relevance of materials and construction features remains vague. Yet, individualized ihZiA are increasingly implemented into daily routine aiming to satisfy rising expectations. The objective was to compare these two types of abutments in fixed dental prostheses (FDP). This cross-sectional study examined 462 implants in 102 patients comparing pTiA (52 patients) to ihZiA (50 patients) for FDP. These different treatment regimens were evaluated in terms of peri-implant health, radiographic bone loss, and oral-health related quality of life (OH-QoL) with special consideration of abutment type and superstructure design. ihZiA showed significantly different design features than prefabricated pTiA, but the annual bone loss in both groups did not. Visible titanium in the esthetic zone negatively impacted OHIP 14 scores. The combination of an emergence angle (EA) of < 30° and a concave emergence profile (EP) as well as gingiva thickness (p = 0.002) at the time of the prosthetic restoration significantly improved the annual peri-implant bone loss, independently of the abutment type. ihZiA showed comparable results to pTiA. To optimize the long-term outcome, not just material alone but generating adequate soft tissue thickness, minimizing the EA, and applying a concave EP seem to be the most relevant factors. To improve OH-QoL, particular attention must be paid to the esthetic zone. ","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"28 1","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cross-sectional analysis comparing prefabricated titanium to individualized hybrid zirconia abutments for cemented zirconia based fixed dental prostheses: a critical concept assessment\",\"authors\":\"Norbert Neckel, Josephine Pohl, Saskia Preissner, Oliver Wagendorf, Claudia Sachse, Kirstin Vach, Max Heiland, Susanne Nahles\",\"doi\":\"10.1186/s40729-024-00529-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Despite the differences in material properties and shapes among the different types of prefabricated titanium (pTiA) and individualized hybrid zirconia abutments (ihZiA), the biological and clinical relevance of materials and construction features remains vague. Yet, individualized ihZiA are increasingly implemented into daily routine aiming to satisfy rising expectations. The objective was to compare these two types of abutments in fixed dental prostheses (FDP). This cross-sectional study examined 462 implants in 102 patients comparing pTiA (52 patients) to ihZiA (50 patients) for FDP. These different treatment regimens were evaluated in terms of peri-implant health, radiographic bone loss, and oral-health related quality of life (OH-QoL) with special consideration of abutment type and superstructure design. ihZiA showed significantly different design features than prefabricated pTiA, but the annual bone loss in both groups did not. Visible titanium in the esthetic zone negatively impacted OHIP 14 scores. The combination of an emergence angle (EA) of < 30° and a concave emergence profile (EP) as well as gingiva thickness (p = 0.002) at the time of the prosthetic restoration significantly improved the annual peri-implant bone loss, independently of the abutment type. ihZiA showed comparable results to pTiA. To optimize the long-term outcome, not just material alone but generating adequate soft tissue thickness, minimizing the EA, and applying a concave EP seem to be the most relevant factors. To improve OH-QoL, particular attention must be paid to the esthetic zone. \",\"PeriodicalId\":14076,\"journal\":{\"name\":\"International Journal of Implant Dentistry\",\"volume\":\"28 1\",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Implant Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40729-024-00529-y\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-024-00529-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

尽管不同类型的预制钛基台(pTiA)和个性化混合氧化锆基台(ihZiA)在材料属性和形状上存在差异,但材料和结构特征在生物学和临床上的相关性仍然模糊不清。然而,为了满足人们日益增长的期望,个性化的 ihZiA 越来越多地应用于日常工作中。研究的目的是比较固定义齿修复体(FDP)中的这两种基台。这项横断面研究对 102 名患者的 462 个种植体进行了检查,比较了用于 FDP 的 pTiA(52 名患者)和 ihZiA(50 名患者)。ihZiA的设计特点与预制pTiA明显不同,但两组患者的年骨质流失量却不相同。美观区内可见的钛对 OHIP 14 评分有负面影响。无论基台类型如何,修复时的出龈角(EA)< 30°、出龈凹面(EP)和牙龈厚度(p = 0.002)都能显著改善种植体周围的年骨量损失。要想获得最佳的长期效果,最重要的因素似乎不仅仅是材料,还包括产生足够的软组织厚度、最大限度地减少 EA 以及采用凹面 EP。要改善 OH-QoL,必须特别关注美学区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cross-sectional analysis comparing prefabricated titanium to individualized hybrid zirconia abutments for cemented zirconia based fixed dental prostheses: a critical concept assessment
Despite the differences in material properties and shapes among the different types of prefabricated titanium (pTiA) and individualized hybrid zirconia abutments (ihZiA), the biological and clinical relevance of materials and construction features remains vague. Yet, individualized ihZiA are increasingly implemented into daily routine aiming to satisfy rising expectations. The objective was to compare these two types of abutments in fixed dental prostheses (FDP). This cross-sectional study examined 462 implants in 102 patients comparing pTiA (52 patients) to ihZiA (50 patients) for FDP. These different treatment regimens were evaluated in terms of peri-implant health, radiographic bone loss, and oral-health related quality of life (OH-QoL) with special consideration of abutment type and superstructure design. ihZiA showed significantly different design features than prefabricated pTiA, but the annual bone loss in both groups did not. Visible titanium in the esthetic zone negatively impacted OHIP 14 scores. The combination of an emergence angle (EA) of < 30° and a concave emergence profile (EP) as well as gingiva thickness (p = 0.002) at the time of the prosthetic restoration significantly improved the annual peri-implant bone loss, independently of the abutment type. ihZiA showed comparable results to pTiA. To optimize the long-term outcome, not just material alone but generating adequate soft tissue thickness, minimizing the EA, and applying a concave EP seem to be the most relevant factors. To improve OH-QoL, particular attention must be paid to the esthetic zone.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
In-vitro investigation of bone temperature changes in osteotomies performed with different brands of implant burs. A digital way to assess the stain parameters that lead to soft tissue blanching when delivering an implant-supported crown. Electroplated double-crowns on implants and teeth after up to 12 years- a retrospective clinical study. The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10-year follow-up and literature review. Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1