Martin Aman, Felix Struebing, Maximilian Mayrhofer-Schmid, Leila Harhaus, Ulrich Kneser, Arne Hendrik Böcker
{"title":"[仿生手术与仿生重建--首次在人体中使用机器人显微手术进行靶向肌肉再支配]。","authors":"Martin Aman, Felix Struebing, Maximilian Mayrhofer-Schmid, Leila Harhaus, Ulrich Kneser, Arne Hendrik Böcker","doi":"10.1055/a-2241-5678","DOIUrl":null,"url":null,"abstract":"<p><p>Robotic microsurgery is an emerging field in reconstructive surgery, which provides benefits such as improved precision, optimal ergonomics, and reduced tremors. However, only a few robotic platforms are available for performing microsurgical procedures, and successful nerve coaptation is still a challenge. Targeted muscle reinnervation (TMR) is an innovative reconstructive procedure that rewires multiple nerves to remnant stump muscles, thereby reducing neuroma and phantom limb pain and improving the control of bionic prostheses. The precision of surgical techniques is critical in reducing axonal sprouting around the coaptation site to minimise the potential for neuroma formation. This study reports the first use of a microsurgical robotic platform for multiple nerve transfers in a patient undergoing TMR for bionic extremity reconstruction. The Symani robotic platform, combined with external microscope magnification, was successfully used, and precise handling of nerve tissue and coaptation was easily feasible even in anatomically challenging environments. While the precision and stability offered by robotic assistance may be especially useful for nerve surgery, the high economic costs of robotic microsurgery remain a major challenge for current healthcare systems. In conclusion, this study demonstrated the feasibility of using a robotic microsurgical platform for nerve surgery and transfers, where precise handling of tissue is crucial and limited space is available. Future studies will explore the full potential of robotic microsurgery in the future.</p>","PeriodicalId":55075,"journal":{"name":"Handchirurgie Mikrochirurgie Plastische Chirurgie","volume":" ","pages":"257-260"},"PeriodicalIF":0.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Bionic Surgery Meets Bionic Reconstruction - First In-human use of Robotic Microsurgery in Targeted Muscle Reinnervation].\",\"authors\":\"Martin Aman, Felix Struebing, Maximilian Mayrhofer-Schmid, Leila Harhaus, Ulrich Kneser, Arne Hendrik Böcker\",\"doi\":\"10.1055/a-2241-5678\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Robotic microsurgery is an emerging field in reconstructive surgery, which provides benefits such as improved precision, optimal ergonomics, and reduced tremors. However, only a few robotic platforms are available for performing microsurgical procedures, and successful nerve coaptation is still a challenge. Targeted muscle reinnervation (TMR) is an innovative reconstructive procedure that rewires multiple nerves to remnant stump muscles, thereby reducing neuroma and phantom limb pain and improving the control of bionic prostheses. The precision of surgical techniques is critical in reducing axonal sprouting around the coaptation site to minimise the potential for neuroma formation. This study reports the first use of a microsurgical robotic platform for multiple nerve transfers in a patient undergoing TMR for bionic extremity reconstruction. The Symani robotic platform, combined with external microscope magnification, was successfully used, and precise handling of nerve tissue and coaptation was easily feasible even in anatomically challenging environments. While the precision and stability offered by robotic assistance may be especially useful for nerve surgery, the high economic costs of robotic microsurgery remain a major challenge for current healthcare systems. In conclusion, this study demonstrated the feasibility of using a robotic microsurgical platform for nerve surgery and transfers, where precise handling of tissue is crucial and limited space is available. Future studies will explore the full potential of robotic microsurgery in the future.</p>\",\"PeriodicalId\":55075,\"journal\":{\"name\":\"Handchirurgie Mikrochirurgie Plastische Chirurgie\",\"volume\":\" \",\"pages\":\"257-260\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Handchirurgie Mikrochirurgie Plastische Chirurgie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2241-5678\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Handchirurgie Mikrochirurgie Plastische Chirurgie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2241-5678","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
[Bionic Surgery Meets Bionic Reconstruction - First In-human use of Robotic Microsurgery in Targeted Muscle Reinnervation].
Robotic microsurgery is an emerging field in reconstructive surgery, which provides benefits such as improved precision, optimal ergonomics, and reduced tremors. However, only a few robotic platforms are available for performing microsurgical procedures, and successful nerve coaptation is still a challenge. Targeted muscle reinnervation (TMR) is an innovative reconstructive procedure that rewires multiple nerves to remnant stump muscles, thereby reducing neuroma and phantom limb pain and improving the control of bionic prostheses. The precision of surgical techniques is critical in reducing axonal sprouting around the coaptation site to minimise the potential for neuroma formation. This study reports the first use of a microsurgical robotic platform for multiple nerve transfers in a patient undergoing TMR for bionic extremity reconstruction. The Symani robotic platform, combined with external microscope magnification, was successfully used, and precise handling of nerve tissue and coaptation was easily feasible even in anatomically challenging environments. While the precision and stability offered by robotic assistance may be especially useful for nerve surgery, the high economic costs of robotic microsurgery remain a major challenge for current healthcare systems. In conclusion, this study demonstrated the feasibility of using a robotic microsurgical platform for nerve surgery and transfers, where precise handling of tissue is crucial and limited space is available. Future studies will explore the full potential of robotic microsurgery in the future.
期刊介绍:
In Originalarbeiten und Fallberichten finden Sie die neuesten Informationen über:
Diagnostik
Verfahrenswahl
state of the art / neueste Techniken
rekonstruktive Verfahren
Behandlung infolge von Traumata oder OP
Bewertung der Ergebnisse
Klinische Forschung
Interessante Darstellung der neuesten Erkenntnisse in Originalarbeiten und Fallberichten. Exzellent
veranschaulicht durch ein klares Layout und reiche Bebilderung. Überzeugen Sie sich selbst!
Organschaften
Organ der Deutschsprachigen Arbeitsgemeinschaft für Handchirurgie, Deutschen Gesellschaft für Handchirurgie und Österreichischen Gesellschaft für Handchirurgie
Organ der Deutschsprachigen Arbeitsgemeinschaft für Mikrochirurgie der peripheren Nerven und Gefäße
Organ der Deutschen Gesellschaft der Plastischen, Rekonstruktiven und Ästhetischen Chirurgen