快速现场评估对计算机断层扫描引导下肺癌核心针活检诊断效果的影响》(The Impact of Rapid On-site Evaluation on Diagnostic Performance of Computed Tomography-Guided Core Needle Biopsy in Lung Cancer)。
Andrea Magnini, Chiara Lorini, Linda Calistri, Francesca Calcagni, Federico Giuntoli, Prassede Foxi, Cosimo Nardi, Stefano Colagrande
{"title":"快速现场评估对计算机断层扫描引导下肺癌核心针活检诊断效果的影响》(The Impact of Rapid On-site Evaluation on Diagnostic Performance of Computed Tomography-Guided Core Needle Biopsy in Lung Cancer)。","authors":"Andrea Magnini, Chiara Lorini, Linda Calistri, Francesca Calcagni, Federico Giuntoli, Prassede Foxi, Cosimo Nardi, Stefano Colagrande","doi":"10.1097/RCT.0000000000001606","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Rapid on-site-evaluation (ROSE) is a technique aimed at improving the diagnostic performance of computed tomography (CT)-guided core needle biopsy (CNB) in lung cancer. The aim of this retrospective study was to investigate the impact of ROSE on the rate of nondiagnostic specimens and on accuracy computed on diagnostic specimens.</p><p><strong>Materials and methods: </strong>During a 3-year period, 417 CT-guided CNBs were performed at our center. The biopsies were retrospectively classified into 2 groups: 141 procedures were assisted by ROSE and 276 were not. All of them were reviewed for clinical, procedural, and pathological data. Pathology results were classified as diagnostic (positive or negative for malignancy) or nondiagnostic. The results were compared with the final diagnosis after surgery or clinical follow-up. Nondiagnostic rate, sensitivity/specificity/negative predictive value/positive predictive value for the ROSE and non-ROSE groups were calculated. Finally, procedural complications and the adequacy of the specimens for the molecular analysis were recorded.</p><p><strong>Results: </strong>The study evaluated 417 CNBs (mean patients' age 71 years, 278 men). Nondiagnostic rates with and without ROSE were 4% (6/142) and 11% (29/276), respectively ( P = 0.028). Sensitivity/specificity/negative predictive value/positive predictive value with and without ROSE did not show statistically significant differences, and no difference in major/minor complication rates was observed between the 2 groups. The adequacy of specimen for subsequent molecular analysis was 100% with (42/42) and 82% without ROSE (51/62).</p><p><strong>Conclusions: </strong>Rapid on-site-evaluation reduced the rate of nondiagnostic specimens by 50% with no change in complication rates or accuracy and increased by 20% the chances of a successful subsequent molecular analysis.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":"803-809"},"PeriodicalIF":1.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Impact of Rapid On-site Evaluation on Diagnostic Performance of Computed Tomography-Guided Core Needle Biopsy in Lung Cancer.\",\"authors\":\"Andrea Magnini, Chiara Lorini, Linda Calistri, Francesca Calcagni, Federico Giuntoli, Prassede Foxi, Cosimo Nardi, Stefano Colagrande\",\"doi\":\"10.1097/RCT.0000000000001606\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Rapid on-site-evaluation (ROSE) is a technique aimed at improving the diagnostic performance of computed tomography (CT)-guided core needle biopsy (CNB) in lung cancer. The aim of this retrospective study was to investigate the impact of ROSE on the rate of nondiagnostic specimens and on accuracy computed on diagnostic specimens.</p><p><strong>Materials and methods: </strong>During a 3-year period, 417 CT-guided CNBs were performed at our center. The biopsies were retrospectively classified into 2 groups: 141 procedures were assisted by ROSE and 276 were not. All of them were reviewed for clinical, procedural, and pathological data. Pathology results were classified as diagnostic (positive or negative for malignancy) or nondiagnostic. The results were compared with the final diagnosis after surgery or clinical follow-up. Nondiagnostic rate, sensitivity/specificity/negative predictive value/positive predictive value for the ROSE and non-ROSE groups were calculated. Finally, procedural complications and the adequacy of the specimens for the molecular analysis were recorded.</p><p><strong>Results: </strong>The study evaluated 417 CNBs (mean patients' age 71 years, 278 men). Nondiagnostic rates with and without ROSE were 4% (6/142) and 11% (29/276), respectively ( P = 0.028). Sensitivity/specificity/negative predictive value/positive predictive value with and without ROSE did not show statistically significant differences, and no difference in major/minor complication rates was observed between the 2 groups. The adequacy of specimen for subsequent molecular analysis was 100% with (42/42) and 82% without ROSE (51/62).</p><p><strong>Conclusions: </strong>Rapid on-site-evaluation reduced the rate of nondiagnostic specimens by 50% with no change in complication rates or accuracy and increased by 20% the chances of a successful subsequent molecular analysis.</p>\",\"PeriodicalId\":15402,\"journal\":{\"name\":\"Journal of Computer Assisted Tomography\",\"volume\":\" \",\"pages\":\"803-809\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Computer Assisted Tomography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RCT.0000000000001606\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001606","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
摘要
目的快速现场评估(ROSE)是一项旨在提高计算机断层扫描(CT)引导下肺癌核心针活检(CNB)诊断性能的技术。这项回顾性研究旨在调查 ROSE 对非诊断标本率和诊断标本准确性计算的影响:本中心在 3 年内进行了 417 例 CT 引导的 CNB。通过回顾性分析,我们将活检分为两组:141 例手术有 ROSE 辅助,276 例没有。我们对所有这些手术的临床、程序和病理数据进行了审查。病理结果分为诊断结果(恶性肿瘤阳性或阴性)和非诊断结果。结果与手术或临床随访后的最终诊断结果进行比较。计算ROSE组和非ROSE组的非诊断率、敏感性/特异性/阴性预测值/阳性预测值。最后,还记录了手术并发症和分子分析标本的充分性:该研究评估了 417 例 CNB(患者平均年龄 71 岁,男性 278 例)。有ROSE和无ROSE的无诊断率分别为4%(6/142)和11%(29/276)(P = 0.028)。使用和不使用 ROSE 的敏感性/特异性/阴性预测值/阳性预测值在统计学上没有显著差异,两组的主要/次要并发症发生率也没有差异。使用 ROSE 和不使用 ROSE 时,标本用于后续分子分析的充分率分别为 100%(42/42)和 82%(51/62):结论:现场快速评估将无诊断标本率降低了 50%,但并发症发生率或准确性没有变化,并将后续分子分析成功的几率提高了 20%。
The Impact of Rapid On-site Evaluation on Diagnostic Performance of Computed Tomography-Guided Core Needle Biopsy in Lung Cancer.
Purpose: Rapid on-site-evaluation (ROSE) is a technique aimed at improving the diagnostic performance of computed tomography (CT)-guided core needle biopsy (CNB) in lung cancer. The aim of this retrospective study was to investigate the impact of ROSE on the rate of nondiagnostic specimens and on accuracy computed on diagnostic specimens.
Materials and methods: During a 3-year period, 417 CT-guided CNBs were performed at our center. The biopsies were retrospectively classified into 2 groups: 141 procedures were assisted by ROSE and 276 were not. All of them were reviewed for clinical, procedural, and pathological data. Pathology results were classified as diagnostic (positive or negative for malignancy) or nondiagnostic. The results were compared with the final diagnosis after surgery or clinical follow-up. Nondiagnostic rate, sensitivity/specificity/negative predictive value/positive predictive value for the ROSE and non-ROSE groups were calculated. Finally, procedural complications and the adequacy of the specimens for the molecular analysis were recorded.
Results: The study evaluated 417 CNBs (mean patients' age 71 years, 278 men). Nondiagnostic rates with and without ROSE were 4% (6/142) and 11% (29/276), respectively ( P = 0.028). Sensitivity/specificity/negative predictive value/positive predictive value with and without ROSE did not show statistically significant differences, and no difference in major/minor complication rates was observed between the 2 groups. The adequacy of specimen for subsequent molecular analysis was 100% with (42/42) and 82% without ROSE (51/62).
Conclusions: Rapid on-site-evaluation reduced the rate of nondiagnostic specimens by 50% with no change in complication rates or accuracy and increased by 20% the chances of a successful subsequent molecular analysis.
期刊介绍:
The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).