哨兵建筑围护结构空气层隔热设计与评估

IF 3.2 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Indoor and Built Environment Pub Date : 2024-03-20 DOI:10.1177/1420326x241240107
Zhu Chang, Haiguo Yin, Yuekun Han, Linfeng Liang
{"title":"哨兵建筑围护结构空气层隔热设计与评估","authors":"Zhu Chang, Haiguo Yin, Yuekun Han, Linfeng Liang","doi":"10.1177/1420326x241240107","DOIUrl":null,"url":null,"abstract":"The prevalence of small-scale structures, such as sentry buildings, has become widespread, with many of these buildings exposed to the outdoor environment and exhibiting suboptimal thermal insulation in their envelopes. Through a comprehensive study of outdoor disturbances, the most unfavourable envelope was identified. In light of this finding, we have designed static air layer sentry buildings (SAL-SB) and dynamic air layer sentry buildings (DAL-SB). The study conducted experiments and numerical simulations to evaluate the impact of air layer thickness, vent opening forms, and inlet velocities on the thermal insulation of sentry buildings. The results showed that both the SAL and DAL effectively improved thermal insulation, and a thickness of 25 cm has been found to offer the best thermal insulation. However, considering the balance between thermal insulation and cost-effectiveness, a thickness of 15 cm is recommended. Additionally, for DAL, an inlet velocity of 3 m/s is the threshold for switching the heat transfer direction on the roof. These findings provide novel insights into enhancing the thermal environment.","PeriodicalId":13578,"journal":{"name":"Indoor and Built Environment","volume":"175 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and evaluation of thermal insulation of air layer for sentry building envelopes\",\"authors\":\"Zhu Chang, Haiguo Yin, Yuekun Han, Linfeng Liang\",\"doi\":\"10.1177/1420326x241240107\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The prevalence of small-scale structures, such as sentry buildings, has become widespread, with many of these buildings exposed to the outdoor environment and exhibiting suboptimal thermal insulation in their envelopes. Through a comprehensive study of outdoor disturbances, the most unfavourable envelope was identified. In light of this finding, we have designed static air layer sentry buildings (SAL-SB) and dynamic air layer sentry buildings (DAL-SB). The study conducted experiments and numerical simulations to evaluate the impact of air layer thickness, vent opening forms, and inlet velocities on the thermal insulation of sentry buildings. The results showed that both the SAL and DAL effectively improved thermal insulation, and a thickness of 25 cm has been found to offer the best thermal insulation. However, considering the balance between thermal insulation and cost-effectiveness, a thickness of 15 cm is recommended. Additionally, for DAL, an inlet velocity of 3 m/s is the threshold for switching the heat transfer direction on the roof. These findings provide novel insights into enhancing the thermal environment.\",\"PeriodicalId\":13578,\"journal\":{\"name\":\"Indoor and Built Environment\",\"volume\":\"175 1\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indoor and Built Environment\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/1420326x241240107\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor and Built Environment","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/1420326x241240107","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

小型建筑(如哨所建筑)已成为一种普遍现象,其中许多建筑都暴露在室外环境中,其围护结构的隔热性能也不尽人意。通过对室外干扰的全面研究,我们确定了最不利的围护结构。根据这一发现,我们设计了静态空气层哨兵建筑(SAL-SB)和动态空气层哨兵建筑(DAL-SB)。研究通过实验和数值模拟,评估了空气层厚度、通风口开口形式和入口速度对哨兵建筑隔热性能的影响。结果表明,SAL 和 DAL 都能有效提高隔热性能,其中 25 厘米的厚度具有最佳隔热性能。不过,考虑到隔热性和成本效益之间的平衡,建议厚度为 15 厘米。此外,对于 DAL 来说,3 米/秒的入口速度是切换屋顶传热方向的临界值。这些发现为改善热环境提供了新的见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and evaluation of thermal insulation of air layer for sentry building envelopes
The prevalence of small-scale structures, such as sentry buildings, has become widespread, with many of these buildings exposed to the outdoor environment and exhibiting suboptimal thermal insulation in their envelopes. Through a comprehensive study of outdoor disturbances, the most unfavourable envelope was identified. In light of this finding, we have designed static air layer sentry buildings (SAL-SB) and dynamic air layer sentry buildings (DAL-SB). The study conducted experiments and numerical simulations to evaluate the impact of air layer thickness, vent opening forms, and inlet velocities on the thermal insulation of sentry buildings. The results showed that both the SAL and DAL effectively improved thermal insulation, and a thickness of 25 cm has been found to offer the best thermal insulation. However, considering the balance between thermal insulation and cost-effectiveness, a thickness of 15 cm is recommended. Additionally, for DAL, an inlet velocity of 3 m/s is the threshold for switching the heat transfer direction on the roof. These findings provide novel insights into enhancing the thermal environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indoor and Built Environment
Indoor and Built Environment 环境科学-工程:环境
CiteScore
6.40
自引率
25.00%
发文量
130
审稿时长
2.6 months
期刊介绍: Indoor and Built Environment publishes reports on any topic pertaining to the quality of the indoor and built environment, and how these might effect the health, performance, efficiency and comfort of persons living or working there. Topics range from urban infrastructure, design of buildings, and materials used to laboratory studies including building airflow simulations and health effects. This journal is a member of the Committee on Publication Ethics (COPE).
期刊最新文献
Dynamics of indoor volatile organic compounds and seasonal ventilation strategies for residential buildings in Northeast China The indoor thermal environment performance of various air-conditioning system configurations and airflow modes in a large space museum building Leakage identification and correlation coefficient method for industrial workshop production process combining with computational fluid dynamics Synthesis and performance study of biomass-based suppressant and its application in radioactive aerosol sedimentation Modelling of radiation and flow fields in in-duct ultraviolet germicidal irradiation systems with and without ribs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1