Krishna Pillai, Javed Akhter, Ahmed H Mekkawy, Sarah J Valle, David L Morris
{"title":"用于定量菠萝蛋白酶的微淀粉酶测定法的开发与验证","authors":"Krishna Pillai, Javed Akhter, Ahmed H Mekkawy, Sarah J Valle, David L Morris","doi":"10.3390/mps7020025","DOIUrl":null,"url":null,"abstract":"<p><p>The proteolytic activity of enzymes may be evaluated by a colorimetric method with azocasein. Hence, we developed a micro-assay to quantify bromelain using azocasein. A total of 250 µL of 1.0% azocasein in dH<sub>2</sub>O was added to 250 µL of test solution, vortexed and incubated at ambient room temperature/30 min. The reaction was terminated with 1500 µL of 5% trichloroacetic acid, vortexed and centrifuged. A total of 150 µL of 0.5M NaOH was added to 150 µL of supernatant in triplicates, and absorbance was recorded at 410 nm. The linearity of the calibration curve was tested with 200-800 µg/mL serial dilutions. The detection limit, precision, accuracy, and robustness were tested along with the substrate enzyme reaction time and solvent matrix effect. Good linearity was seen with serially diluted 200 µg/mL bromelain. The limit of quantification and limit of detection were 5.412 and 16.4 µg/mL, respectively. Intra-day and inter-day analyses showed a relative standard deviation below 2.0%. The assay was robust when tested over 400-450 nm wavelengths. The assays performed using dH<sub>2</sub>O or PBS diluents indicated a higher sensitivity in dH<sub>2</sub>O. The proteolytic activity of bromelain was enhanced with L-cysteine or N-acetylcysteine. Hence, this micro-azocasein assay is reliable for quantifying bromelain.</p>","PeriodicalId":18715,"journal":{"name":"Methods and Protocols","volume":"7 2","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10961761/pdf/","citationCount":"0","resultStr":"{\"title\":\"Development and Validation of Micro-Azocasein Assay for Quantifying Bromelain.\",\"authors\":\"Krishna Pillai, Javed Akhter, Ahmed H Mekkawy, Sarah J Valle, David L Morris\",\"doi\":\"10.3390/mps7020025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The proteolytic activity of enzymes may be evaluated by a colorimetric method with azocasein. Hence, we developed a micro-assay to quantify bromelain using azocasein. A total of 250 µL of 1.0% azocasein in dH<sub>2</sub>O was added to 250 µL of test solution, vortexed and incubated at ambient room temperature/30 min. The reaction was terminated with 1500 µL of 5% trichloroacetic acid, vortexed and centrifuged. A total of 150 µL of 0.5M NaOH was added to 150 µL of supernatant in triplicates, and absorbance was recorded at 410 nm. The linearity of the calibration curve was tested with 200-800 µg/mL serial dilutions. The detection limit, precision, accuracy, and robustness were tested along with the substrate enzyme reaction time and solvent matrix effect. Good linearity was seen with serially diluted 200 µg/mL bromelain. The limit of quantification and limit of detection were 5.412 and 16.4 µg/mL, respectively. Intra-day and inter-day analyses showed a relative standard deviation below 2.0%. The assay was robust when tested over 400-450 nm wavelengths. The assays performed using dH<sub>2</sub>O or PBS diluents indicated a higher sensitivity in dH<sub>2</sub>O. The proteolytic activity of bromelain was enhanced with L-cysteine or N-acetylcysteine. Hence, this micro-azocasein assay is reliable for quantifying bromelain.</p>\",\"PeriodicalId\":18715,\"journal\":{\"name\":\"Methods and Protocols\",\"volume\":\"7 2\",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10961761/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Methods and Protocols\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/mps7020025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/mps7020025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Development and Validation of Micro-Azocasein Assay for Quantifying Bromelain.
The proteolytic activity of enzymes may be evaluated by a colorimetric method with azocasein. Hence, we developed a micro-assay to quantify bromelain using azocasein. A total of 250 µL of 1.0% azocasein in dH2O was added to 250 µL of test solution, vortexed and incubated at ambient room temperature/30 min. The reaction was terminated with 1500 µL of 5% trichloroacetic acid, vortexed and centrifuged. A total of 150 µL of 0.5M NaOH was added to 150 µL of supernatant in triplicates, and absorbance was recorded at 410 nm. The linearity of the calibration curve was tested with 200-800 µg/mL serial dilutions. The detection limit, precision, accuracy, and robustness were tested along with the substrate enzyme reaction time and solvent matrix effect. Good linearity was seen with serially diluted 200 µg/mL bromelain. The limit of quantification and limit of detection were 5.412 and 16.4 µg/mL, respectively. Intra-day and inter-day analyses showed a relative standard deviation below 2.0%. The assay was robust when tested over 400-450 nm wavelengths. The assays performed using dH2O or PBS diluents indicated a higher sensitivity in dH2O. The proteolytic activity of bromelain was enhanced with L-cysteine or N-acetylcysteine. Hence, this micro-azocasein assay is reliable for quantifying bromelain.