基于超声的非对比微血管成像评估乳腺病变:成像技术和诊断标准回顾

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Indian Journal of Radiology and Imaging Pub Date : 2024-03-17 DOI:10.1055/s-0044-1782162
Namita Mohindra, N. Soni
{"title":"基于超声的非对比微血管成像评估乳腺病变:成像技术和诊断标准回顾","authors":"Namita Mohindra, N. Soni","doi":"10.1055/s-0044-1782162","DOIUrl":null,"url":null,"abstract":"Vascularity plays a pivotal role in the progression of breast lesions and may be associated with their aggressiveness and likelihood of being malignant. Contrast-enhanced imaging techniques are necessary to evaluate vascularity due to the limited sensitivity of conventional color Doppler techniques, in which motion artifacts are eliminated using wall filters. However, in this process, low-flow signals from small vessels also get removed unintentionally. Advancements in technology have revolutionized the way ultrasound images are generated, resulting in tremendous improvements in Doppler imaging techniques. The new, ultrasound-based noncontrast microvascular imaging techniques overcome the limitations of conventional Doppler, and are highly sensitive for detecting microvessels and low flow. The resultant high Doppler sensitivity leads to detection of vascularity in more breast lesions. It is important for radiologists to understand the imaging principles and the clinical implications of the new techniques, to optimally utilize them and aid correct diagnosis. Angio-PLUS is one such recent advancement, which uses unfocused or plane waves and three-dimensional wall filtering to analyze tissue motion in time, space, and amplitude domains that effectively distinguish between blood flow and tissue. The information is beneficial for assessing the lesion vascularity without using contrast. This article aims to explain the Doppler imaging techniques, their clinical applications, scanning methods, and review the common Doppler-based diagnostic criteria used in the evaluation of breast lesions.","PeriodicalId":51597,"journal":{"name":"Indian Journal of Radiology and Imaging","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasound-Based Noncontrast Microvascular Imaging for Evaluation of Breast Lesions: Imaging Techniques and Review of Diagnostic Criteria\",\"authors\":\"Namita Mohindra, N. Soni\",\"doi\":\"10.1055/s-0044-1782162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Vascularity plays a pivotal role in the progression of breast lesions and may be associated with their aggressiveness and likelihood of being malignant. Contrast-enhanced imaging techniques are necessary to evaluate vascularity due to the limited sensitivity of conventional color Doppler techniques, in which motion artifacts are eliminated using wall filters. However, in this process, low-flow signals from small vessels also get removed unintentionally. Advancements in technology have revolutionized the way ultrasound images are generated, resulting in tremendous improvements in Doppler imaging techniques. The new, ultrasound-based noncontrast microvascular imaging techniques overcome the limitations of conventional Doppler, and are highly sensitive for detecting microvessels and low flow. The resultant high Doppler sensitivity leads to detection of vascularity in more breast lesions. It is important for radiologists to understand the imaging principles and the clinical implications of the new techniques, to optimally utilize them and aid correct diagnosis. Angio-PLUS is one such recent advancement, which uses unfocused or plane waves and three-dimensional wall filtering to analyze tissue motion in time, space, and amplitude domains that effectively distinguish between blood flow and tissue. The information is beneficial for assessing the lesion vascularity without using contrast. This article aims to explain the Doppler imaging techniques, their clinical applications, scanning methods, and review the common Doppler-based diagnostic criteria used in the evaluation of breast lesions.\",\"PeriodicalId\":51597,\"journal\":{\"name\":\"Indian Journal of Radiology and Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Radiology and Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1782162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Radiology and Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1782162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

血管在乳腺病变的发展过程中起着至关重要的作用,可能与病变的侵袭性和恶变的可能性有关。由于传统彩色多普勒技术的灵敏度有限,需要使用对比增强成像技术来评估血管性。然而,在此过程中,小血管的低流量信号也会无意中被去除。技术的进步彻底改变了超声图像的生成方式,从而极大地改进了多普勒成像技术。基于超声的新型非对比微血管成像技术克服了传统多普勒的局限性,在检测微血管和低流量方面具有极高的灵敏度。由此产生的高多普勒灵敏度可检测到更多乳腺病变中的血管。放射科医生必须了解新技术的成像原理和临床意义,才能最佳地利用这些技术,帮助做出正确的诊断。Angio-PLUS就是最近的一项新技术,它利用非聚焦或平面波和三维壁滤波来分析组织在时间、空间和振幅域的运动,从而有效区分血流和组织。这些信息有利于在不使用造影剂的情况下评估病变血管。本文旨在解释多普勒成像技术及其临床应用、扫描方法,并回顾乳腺病变评估中常用的基于多普勒的诊断标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasound-Based Noncontrast Microvascular Imaging for Evaluation of Breast Lesions: Imaging Techniques and Review of Diagnostic Criteria
Vascularity plays a pivotal role in the progression of breast lesions and may be associated with their aggressiveness and likelihood of being malignant. Contrast-enhanced imaging techniques are necessary to evaluate vascularity due to the limited sensitivity of conventional color Doppler techniques, in which motion artifacts are eliminated using wall filters. However, in this process, low-flow signals from small vessels also get removed unintentionally. Advancements in technology have revolutionized the way ultrasound images are generated, resulting in tremendous improvements in Doppler imaging techniques. The new, ultrasound-based noncontrast microvascular imaging techniques overcome the limitations of conventional Doppler, and are highly sensitive for detecting microvessels and low flow. The resultant high Doppler sensitivity leads to detection of vascularity in more breast lesions. It is important for radiologists to understand the imaging principles and the clinical implications of the new techniques, to optimally utilize them and aid correct diagnosis. Angio-PLUS is one such recent advancement, which uses unfocused or plane waves and three-dimensional wall filtering to analyze tissue motion in time, space, and amplitude domains that effectively distinguish between blood flow and tissue. The information is beneficial for assessing the lesion vascularity without using contrast. This article aims to explain the Doppler imaging techniques, their clinical applications, scanning methods, and review the common Doppler-based diagnostic criteria used in the evaluation of breast lesions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Journal of Radiology and Imaging
Indian Journal of Radiology and Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.20
自引率
0.00%
发文量
115
审稿时长
45 weeks
期刊介绍: Information not localized
期刊最新文献
A Reflection of Our Role as Radiologists in India's Current Landscape of Infectious Diseases. Multimodality Imaging in the Diagnosis and Staging of Gestational Choriocarcinoma Rare Presentations of Takayasu Arteritis: A Case Series Sonographic Assessment of Isthmocele and Its Obstetric Complications in Subsequent Pregnancies: A Pictorial Review Exploring Radiology Postgraduate Students' Engagement with Large Language Models for Educational Purposes: A Study of Knowledge, Attitudes, and Practices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1