{"title":"用于核磁共振成像引导介入手术的患者特异性三维打印和基于注射液材料的定位网格","authors":"Vivien W S Chu, Wing Ki Wong, Louis Lee","doi":"10.1115/1.4065054","DOIUrl":null,"url":null,"abstract":"\n In view of the lack of commercially available localization grids for MRI-guided interventional procedures, two customizable and easily fabricable grids are proposed. The first one is a patient-specific 3D-printed localization grid that incorporates MRI markers, while the second one is a grid constructed with Superflex Transparent Bolus material. MRI scans were performed with the grids attached on an abdominal phantom. The patient-specific 3D printed grid is visible in T1-weighted, T2-weighted, proton density (PD) and FLAIR MR images, whereas the Superflex grid is visible only in T1-weighted and PD images. However, the Superflex grid offers the advantage of a simpler fabrication process and being more cost-effective. Both proposed localization grids can facilitate the determination of the optimal needle entry positions for MRI-guided interventional procedures, leading to reduced overall procedure time and improved efficiency.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"58 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Patient-Specific 3D-Printed and Bolus Material-Based Localization Grids for MRI-Guided Interventional Procedures\",\"authors\":\"Vivien W S Chu, Wing Ki Wong, Louis Lee\",\"doi\":\"10.1115/1.4065054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n In view of the lack of commercially available localization grids for MRI-guided interventional procedures, two customizable and easily fabricable grids are proposed. The first one is a patient-specific 3D-printed localization grid that incorporates MRI markers, while the second one is a grid constructed with Superflex Transparent Bolus material. MRI scans were performed with the grids attached on an abdominal phantom. The patient-specific 3D printed grid is visible in T1-weighted, T2-weighted, proton density (PD) and FLAIR MR images, whereas the Superflex grid is visible only in T1-weighted and PD images. However, the Superflex grid offers the advantage of a simpler fabrication process and being more cost-effective. Both proposed localization grids can facilitate the determination of the optimal needle entry positions for MRI-guided interventional procedures, leading to reduced overall procedure time and improved efficiency.\",\"PeriodicalId\":506673,\"journal\":{\"name\":\"Journal of Medical Devices\",\"volume\":\"58 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4065054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4065054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Patient-Specific 3D-Printed and Bolus Material-Based Localization Grids for MRI-Guided Interventional Procedures
In view of the lack of commercially available localization grids for MRI-guided interventional procedures, two customizable and easily fabricable grids are proposed. The first one is a patient-specific 3D-printed localization grid that incorporates MRI markers, while the second one is a grid constructed with Superflex Transparent Bolus material. MRI scans were performed with the grids attached on an abdominal phantom. The patient-specific 3D printed grid is visible in T1-weighted, T2-weighted, proton density (PD) and FLAIR MR images, whereas the Superflex grid is visible only in T1-weighted and PD images. However, the Superflex grid offers the advantage of a simpler fabrication process and being more cost-effective. Both proposed localization grids can facilitate the determination of the optimal needle entry positions for MRI-guided interventional procedures, leading to reduced overall procedure time and improved efficiency.