使用可变积分周期测量和评估 2 × 25 kV 50 Hz 高速列车的电压不平衡度

Yassine Taleb, Roa Lamrani, Ahmed Abbou
{"title":"使用可变积分周期测量和评估 2 × 25 kV 50 Hz 高速列车的电压不平衡度","authors":"Yassine Taleb, Roa Lamrani, Ahmed Abbou","doi":"10.3390/electricity5010009","DOIUrl":null,"url":null,"abstract":"This article addresses the need for a standardized method to measure power quality in railroad systems, which differ from distribution and transmission networks. It evaluates the applicability of existing standards in detecting variations and short-term disturbances in railroad networks powered by the 50/60 Hz AC grid or the 2 × 25 kV AC network used for high-speed trains. The objective is to propose a standardized algorithm capable of accurately identifying disturbances to assess power quality on railway traction substations. A new method is proposed to characterize voltage imbalances more precisely. Practical demonstrations confirm that a short integration period, as used in existing standards, provides a more accurate estimation of disturbance amplitude and duration. Field experiments validate the proposed solution, embedded in equipment installed on the 225 kV line supplying the 2 × 25 kV AC substation for high-speed rail. Comparative analysis of results obtained during high-speed train journeys confirms the algorithm’s potential to aid standards committees in reviewing and updating existing standards, as well as expediting the creation, approval, and implementation of new standards for railway installations. Experimental comparisons of other power quality parameters, such as frequency and voltage harmonics, also underscore the algorithm’s utility in railway power quality assessment.","PeriodicalId":69873,"journal":{"name":"Electricity","volume":"2 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement and Evaluation of Voltage Unbalance in 2 × 25 kV 50 Hz High-Speed Trains Using Variable Integration Period\",\"authors\":\"Yassine Taleb, Roa Lamrani, Ahmed Abbou\",\"doi\":\"10.3390/electricity5010009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article addresses the need for a standardized method to measure power quality in railroad systems, which differ from distribution and transmission networks. It evaluates the applicability of existing standards in detecting variations and short-term disturbances in railroad networks powered by the 50/60 Hz AC grid or the 2 × 25 kV AC network used for high-speed trains. The objective is to propose a standardized algorithm capable of accurately identifying disturbances to assess power quality on railway traction substations. A new method is proposed to characterize voltage imbalances more precisely. Practical demonstrations confirm that a short integration period, as used in existing standards, provides a more accurate estimation of disturbance amplitude and duration. Field experiments validate the proposed solution, embedded in equipment installed on the 225 kV line supplying the 2 × 25 kV AC substation for high-speed rail. Comparative analysis of results obtained during high-speed train journeys confirms the algorithm’s potential to aid standards committees in reviewing and updating existing standards, as well as expediting the creation, approval, and implementation of new standards for railway installations. Experimental comparisons of other power quality parameters, such as frequency and voltage harmonics, also underscore the algorithm’s utility in railway power quality assessment.\",\"PeriodicalId\":69873,\"journal\":{\"name\":\"Electricity\",\"volume\":\"2 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electricity\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.3390/electricity5010009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electricity","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3390/electricity5010009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文探讨了铁路系统电能质量测量标准化方法的必要性,因为铁路系统不同于配电和输电网络。文章评估了现有标准在检测由 50/60 Hz 交流电网或高速列车使用的 2 × 25 kV 交流网络供电的铁路网络中的变化和短期干扰方面的适用性。其目的是提出一种能够准确识别干扰的标准化算法,以评估铁路牵引变电站的电能质量。此外,还提出了一种新方法来更精确地描述电压不平衡。实际演示证实,现有标准中使用的短积分周期能更准确地估算干扰幅值和持续时间。现场实验验证了所提出的解决方案,该方案安装在为高铁 2 × 25 千伏交流变电站供电的 225 千伏线路上。对高速列车运行过程中获得的结果进行的比较分析证实,该算法可帮助标准委员会审查和更新现有标准,并加快铁路设施新标准的制定、批准和实施。对其他电能质量参数(如频率和电压谐波)的实验比较也凸显了该算法在铁路电能质量评估中的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement and Evaluation of Voltage Unbalance in 2 × 25 kV 50 Hz High-Speed Trains Using Variable Integration Period
This article addresses the need for a standardized method to measure power quality in railroad systems, which differ from distribution and transmission networks. It evaluates the applicability of existing standards in detecting variations and short-term disturbances in railroad networks powered by the 50/60 Hz AC grid or the 2 × 25 kV AC network used for high-speed trains. The objective is to propose a standardized algorithm capable of accurately identifying disturbances to assess power quality on railway traction substations. A new method is proposed to characterize voltage imbalances more precisely. Practical demonstrations confirm that a short integration period, as used in existing standards, provides a more accurate estimation of disturbance amplitude and duration. Field experiments validate the proposed solution, embedded in equipment installed on the 225 kV line supplying the 2 × 25 kV AC substation for high-speed rail. Comparative analysis of results obtained during high-speed train journeys confirms the algorithm’s potential to aid standards committees in reviewing and updating existing standards, as well as expediting the creation, approval, and implementation of new standards for railway installations. Experimental comparisons of other power quality parameters, such as frequency and voltage harmonics, also underscore the algorithm’s utility in railway power quality assessment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.80
自引率
0.00%
发文量
1584
期刊最新文献
Renewable Electricity and Green Hydrogen Integration for Decarbonization of “Hard-to-Abate” Industrial Sectors Dynamic Consensus-Based ADMM Strategy for Economic Dispatch with Demand Response in Power Grids Hardware-in-the-Loop Emulation of a SEPIC Multiplier Converter in a Photovoltaic System Enhancing Distribution Grid Efficiency and Congestion Management through Optimal Battery Storage and Power Flow Modeling Electricity Theft Detection and Prevention Using Technology-Based Models: A Systematic Literature Review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1