{"title":"经导管主动脉瓣置换-传导研究:His 室间隔在经导管主动脉瓣置换术后房室传导阻滞风险分层中的价值","authors":"","doi":"10.1016/j.shj.2024.100296","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>There is no clear consensus regarding the optimal risk stratification of high-degree atrioventricular block (HDAVB) after transcatheter aortic valve replacement (TAVR).</p></div><div><h3>Methods</h3><p>This prospective study sought to determine the utility of the pre- and post-TAVR His-ventricular (HV) interval in the risk stratification of post-TAVR HDAVB. One hundred twenty-one patients underwent an electrophysiology study before and after TAVR. The primary outcome was HDAVB requiring pacemaker implantation within 30 days post-TAVR. A separate retrospective cohort was analyzed to determine the postoperative interval at which the risk of HDAVB is reduced to <5%.</p></div><div><h3>Results</h3><p>HDAVB occurred in 12 (10%) patients. Baseline right bundle branch block (RBBB) (odds ratio [OR]: 13.6), implant depth >4 mm (OR: 3.9), use of mechanically- or self-expanding valves (OR: 6.3), and post-TAVR HV > 65 ms (OR: 4.9) were associated with increased risk of HDAVB, whereas PR intervals and pre-TAVR HV were not. In patients without baseline RBBB or new persistent left bundle branch block (LBBB), not one patient with post-TAVR HV < 65 ms developed HDAVB. In the separate retrospective cohort (N = 1049), the risk of HDAVB is reduced (<5%) on postoperative days 4 and 3 in patients with pre-TAVR RBBB and post-TAVR persistent LBBB, respectively.</p></div><div><h3>Conclusions</h3><p>Baseline RBBB, new persistent LBBB, implant depth >4 mm, and a post-TAVR HV ≥ 65 ms were associated with a higher risk of post-TAVR HDAVB, whereas an HV ≤ 65 ms was associated with a lower risk. The pre-TAVR HV was not associated with our outcome, and the delta HV did not have practical incremental prognostic value. Among those without pre-TAVR RBBB or post-TAVR persistent LBBB, no patients with post-TAVR HV < 65 ms developed HDAVB.</p></div>","PeriodicalId":36053,"journal":{"name":"Structural Heart","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2474870624000277/pdfft?md5=580d9deba1c9f66932a432b36eb32ecc&pid=1-s2.0-S2474870624000277-main.pdf","citationCount":"0","resultStr":"{\"title\":\"The Transcatheter Aortic Valve Replacement-Conduction Study: The Value of the His-Ventricular Interval in Risk Stratification for Post-TAVR Atrioventricular-Block\",\"authors\":\"\",\"doi\":\"10.1016/j.shj.2024.100296\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>There is no clear consensus regarding the optimal risk stratification of high-degree atrioventricular block (HDAVB) after transcatheter aortic valve replacement (TAVR).</p></div><div><h3>Methods</h3><p>This prospective study sought to determine the utility of the pre- and post-TAVR His-ventricular (HV) interval in the risk stratification of post-TAVR HDAVB. One hundred twenty-one patients underwent an electrophysiology study before and after TAVR. The primary outcome was HDAVB requiring pacemaker implantation within 30 days post-TAVR. A separate retrospective cohort was analyzed to determine the postoperative interval at which the risk of HDAVB is reduced to <5%.</p></div><div><h3>Results</h3><p>HDAVB occurred in 12 (10%) patients. Baseline right bundle branch block (RBBB) (odds ratio [OR]: 13.6), implant depth >4 mm (OR: 3.9), use of mechanically- or self-expanding valves (OR: 6.3), and post-TAVR HV > 65 ms (OR: 4.9) were associated with increased risk of HDAVB, whereas PR intervals and pre-TAVR HV were not. In patients without baseline RBBB or new persistent left bundle branch block (LBBB), not one patient with post-TAVR HV < 65 ms developed HDAVB. In the separate retrospective cohort (N = 1049), the risk of HDAVB is reduced (<5%) on postoperative days 4 and 3 in patients with pre-TAVR RBBB and post-TAVR persistent LBBB, respectively.</p></div><div><h3>Conclusions</h3><p>Baseline RBBB, new persistent LBBB, implant depth >4 mm, and a post-TAVR HV ≥ 65 ms were associated with a higher risk of post-TAVR HDAVB, whereas an HV ≤ 65 ms was associated with a lower risk. The pre-TAVR HV was not associated with our outcome, and the delta HV did not have practical incremental prognostic value. Among those without pre-TAVR RBBB or post-TAVR persistent LBBB, no patients with post-TAVR HV < 65 ms developed HDAVB.</p></div>\",\"PeriodicalId\":36053,\"journal\":{\"name\":\"Structural Heart\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2474870624000277/pdfft?md5=580d9deba1c9f66932a432b36eb32ecc&pid=1-s2.0-S2474870624000277-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Heart\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2474870624000277\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Heart","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2474870624000277","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
The Transcatheter Aortic Valve Replacement-Conduction Study: The Value of the His-Ventricular Interval in Risk Stratification for Post-TAVR Atrioventricular-Block
Background
There is no clear consensus regarding the optimal risk stratification of high-degree atrioventricular block (HDAVB) after transcatheter aortic valve replacement (TAVR).
Methods
This prospective study sought to determine the utility of the pre- and post-TAVR His-ventricular (HV) interval in the risk stratification of post-TAVR HDAVB. One hundred twenty-one patients underwent an electrophysiology study before and after TAVR. The primary outcome was HDAVB requiring pacemaker implantation within 30 days post-TAVR. A separate retrospective cohort was analyzed to determine the postoperative interval at which the risk of HDAVB is reduced to <5%.
Results
HDAVB occurred in 12 (10%) patients. Baseline right bundle branch block (RBBB) (odds ratio [OR]: 13.6), implant depth >4 mm (OR: 3.9), use of mechanically- or self-expanding valves (OR: 6.3), and post-TAVR HV > 65 ms (OR: 4.9) were associated with increased risk of HDAVB, whereas PR intervals and pre-TAVR HV were not. In patients without baseline RBBB or new persistent left bundle branch block (LBBB), not one patient with post-TAVR HV < 65 ms developed HDAVB. In the separate retrospective cohort (N = 1049), the risk of HDAVB is reduced (<5%) on postoperative days 4 and 3 in patients with pre-TAVR RBBB and post-TAVR persistent LBBB, respectively.
Conclusions
Baseline RBBB, new persistent LBBB, implant depth >4 mm, and a post-TAVR HV ≥ 65 ms were associated with a higher risk of post-TAVR HDAVB, whereas an HV ≤ 65 ms was associated with a lower risk. The pre-TAVR HV was not associated with our outcome, and the delta HV did not have practical incremental prognostic value. Among those without pre-TAVR RBBB or post-TAVR persistent LBBB, no patients with post-TAVR HV < 65 ms developed HDAVB.