在银屑病关节炎的初步 GLobal OMERACT 超声ctylitis Score (GLOUDAS) 中验证并纳入数字粘连。

IF 20.3 1区 医学 Q1 RHEUMATOLOGY Annals of the Rheumatic Diseases Pub Date : 2024-07-15 DOI:10.1136/ard-2023-225278
Esperanza Naredo, Maria Antonietta D'Agostino, Lene Terslev, Carlos Pineda, M Isabel Miguel, Joan Blasi, George A Bruyn, Marion C Kortekaas, Peter Mandl, Rodina Nestorova, Marcin Szkudlarek, Plamen Todorov, Violeta Vlad, Priscilla Wong, Catherine Bakewell, Emilio Filippucci, Alen Zabotti, Mihaela Micu, Florentin Vreju, Mohamed Mortada, José Alexandre Mendonça, Carlos A Guillen-Astete, Otto Olivas-Vergara, Annamaria Iagnocco, Petra Hanova, Ilaria Tinazzi, Peter V Balint, Sibel Zehra Aydin, David Kane, Helen Keen, Gurjit S Kaeley, Ingrid Möller
{"title":"在银屑病关节炎的初步 GLobal OMERACT 超声ctylitis Score (GLOUDAS) 中验证并纳入数字粘连。","authors":"Esperanza Naredo, Maria Antonietta D'Agostino, Lene Terslev, Carlos Pineda, M Isabel Miguel, Joan Blasi, George A Bruyn, Marion C Kortekaas, Peter Mandl, Rodina Nestorova, Marcin Szkudlarek, Plamen Todorov, Violeta Vlad, Priscilla Wong, Catherine Bakewell, Emilio Filippucci, Alen Zabotti, Mihaela Micu, Florentin Vreju, Mohamed Mortada, José Alexandre Mendonça, Carlos A Guillen-Astete, Otto Olivas-Vergara, Annamaria Iagnocco, Petra Hanova, Ilaria Tinazzi, Peter V Balint, Sibel Zehra Aydin, David Kane, Helen Keen, Gurjit S Kaeley, Ingrid Möller","doi":"10.1136/ard-2023-225278","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system.</p><p><strong>Methods: </strong>The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis.</p><p><strong>Results: </strong>32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes).</p><p><strong>Conclusions: </strong>We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.</p>","PeriodicalId":8087,"journal":{"name":"Annals of the Rheumatic Diseases","volume":null,"pages":null},"PeriodicalIF":20.3000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation and incorporation of digital entheses into a preliminary GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis.\",\"authors\":\"Esperanza Naredo, Maria Antonietta D'Agostino, Lene Terslev, Carlos Pineda, M Isabel Miguel, Joan Blasi, George A Bruyn, Marion C Kortekaas, Peter Mandl, Rodina Nestorova, Marcin Szkudlarek, Plamen Todorov, Violeta Vlad, Priscilla Wong, Catherine Bakewell, Emilio Filippucci, Alen Zabotti, Mihaela Micu, Florentin Vreju, Mohamed Mortada, José Alexandre Mendonça, Carlos A Guillen-Astete, Otto Olivas-Vergara, Annamaria Iagnocco, Petra Hanova, Ilaria Tinazzi, Peter V Balint, Sibel Zehra Aydin, David Kane, Helen Keen, Gurjit S Kaeley, Ingrid Möller\",\"doi\":\"10.1136/ard-2023-225278\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system.</p><p><strong>Methods: </strong>The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis.</p><p><strong>Results: </strong>32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes).</p><p><strong>Conclusions: </strong>We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.</p>\",\"PeriodicalId\":8087,\"journal\":{\"name\":\"Annals of the Rheumatic Diseases\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":20.3000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of the Rheumatic Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/ard-2023-225278\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RHEUMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of the Rheumatic Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/ard-2023-225278","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RHEUMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目标:主要目的是制定银屑病关节炎的 GLobal OMERACT 超声直肠炎评分(GLOUDAS),并测试其可靠性。为此,我们评估了手指内侧超声评估的有效性、可行性和适用性,以便将其纳入评分系统:研究包括一个循序渐进的过程。首先,在尸体标本中,我们通过超声波和大体解剖确定了手指的内趾部位,然后在组织学样本中验证了内趾组织的存在。然后,我们通过德尔菲法(Delphi)与国际专家达成共识,选出将纳入趾关节炎评分系统的内趾。接下来,我们采用德尔菲法建立并定义了趾关节炎的超声成分及其评分系统。最后,我们测试了基于共识的评分系统在银屑病趾关节炎患者中的观察者间和观察者内的可靠性:结果:在尸体手指中发现了 32 个内趾。结果:在尸体手指中发现了 32 个夹趾,所有尸体样本中的夹趾组织均得到证实。在达成共识后,其中 12 个内趾被选入 GLOUDAS。通过德尔菲程序商定的 GLOUDAS 超声波检查项目包括滑膜炎、腱鞘炎、夹骨膜炎、皮下组织炎症和伸肌腱周围炎症。各组成部分的评分系统也已达成一致。对于趾关节炎的组成部分,观察者之间的可靠性从一般到良好(κ 0.39-0.71),观察者内部的可靠性从良好到优秀(κ 0.80-0.88)。B模式和多普勒模式总分(单个异常的得分总和)的观察者间和观察者内一致性极佳(B模式观察者间平级内相关系数(ICC)为0.98,多普勒模式为0.99;两种模式观察者内ICC均为0.98):结论:我们已经建立了一套由共识驱动的超声趾间关节炎评分系统,该系统的观察者间可靠性和观察者内可靠性均可接受。通过解剖学知识,我们确定了手指的小关节,并在组织学上进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validation and incorporation of digital entheses into a preliminary GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis.

Objectives: The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system.

Methods: The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis.

Results: 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes).

Conclusions: We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of the Rheumatic Diseases
Annals of the Rheumatic Diseases 医学-风湿病学
CiteScore
35.00
自引率
9.90%
发文量
3728
审稿时长
1.4 months
期刊介绍: Annals of the Rheumatic Diseases (ARD) is an international peer-reviewed journal covering all aspects of rheumatology, which includes the full spectrum of musculoskeletal conditions, arthritic disease, and connective tissue disorders. ARD publishes basic, clinical, and translational scientific research, including the most important recommendations for the management of various conditions.
期刊最新文献
ITGA5+ synovial fibroblasts orchestrate proinflammatory niche formation by remodelling the local immune microenvironment in rheumatoid arthritis. Uncovering specific genetic-respiratory disease endotypes for rheumatoid arthritis risk. Vascular occlusion for optimising the functional improvement in patients with knee osteoarthritis: a randomised controlled trial. Comparison of two strategies of glucocorticoid withdrawal in patients with rheumatoid arthritis in low disease activity (STAR): a randomised, placebo-controlled, double-blind trial. Evidence that autoantibody production may be driven by acute Epstein-Barr virus infection in Sjögren's disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1