Mattias A S Henning, Hajer I Al-Rahimi, Gregor B E Jemec, Ole B Pedersen
{"title":"原发性多汗症诊断标准简表的诊断准确性。","authors":"Mattias A S Henning, Hajer I Al-Rahimi, Gregor B E Jemec, Ole B Pedersen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The gold standard method for diagnosing primary hyperhidrosis (PHH) is based on seven patient-reported criteria. By determining an individual criterion's diagnostic accuracy, one can identify short-version classification models.</p><p><strong>Methods: </strong>In this cross-sectional study, data were collected from Danish blood donors in 2021. Cohen's kappa and diagnostic accuracy were determined by comparing each criterion with the gold standard method.</p><p><strong>Results: </strong>The study included 1,039 participants. Of them, 59 (5.7%) had PHH and 980 (94.3%) were classified as control individuals. The PHH major criterion \"focal visible excessive sweating for at least 6 months without an apparent cause\" had the highest prevalence in the participants with PHH compared to the control individuals (100% vs. 0.6%; p < 0.0001). The agreement between this criterion and PHH was Cohen's kappa = 0.95 (95% confidence interval [CI] 0.91-0.99), and its sensitivity was 1.00 (95% CI 0.94-1.00) and specificity 0.99 (95% CI 0.99-1.00). The other criteria showed lower agreement and diagnostic accuracy.</p><p><strong>Conclusions: </strong>The PHH major criterion showed near-perfect agreement and near-equal diagnostic accuracy compared with the gold standard method. This single criterion can be used as a short-form version to screen for PHH. Determination of reproducibility in independent populations is warranted.</p>","PeriodicalId":45914,"journal":{"name":"Acta Dermatovenerologica Alpina Pannonica et Adriatica","volume":"33 1","pages":"17-22"},"PeriodicalIF":0.6000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic accuracy of a short-form version of the diagnostic criteria for primary hyperhidrosis.\",\"authors\":\"Mattias A S Henning, Hajer I Al-Rahimi, Gregor B E Jemec, Ole B Pedersen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The gold standard method for diagnosing primary hyperhidrosis (PHH) is based on seven patient-reported criteria. By determining an individual criterion's diagnostic accuracy, one can identify short-version classification models.</p><p><strong>Methods: </strong>In this cross-sectional study, data were collected from Danish blood donors in 2021. Cohen's kappa and diagnostic accuracy were determined by comparing each criterion with the gold standard method.</p><p><strong>Results: </strong>The study included 1,039 participants. Of them, 59 (5.7%) had PHH and 980 (94.3%) were classified as control individuals. The PHH major criterion \\\"focal visible excessive sweating for at least 6 months without an apparent cause\\\" had the highest prevalence in the participants with PHH compared to the control individuals (100% vs. 0.6%; p < 0.0001). The agreement between this criterion and PHH was Cohen's kappa = 0.95 (95% confidence interval [CI] 0.91-0.99), and its sensitivity was 1.00 (95% CI 0.94-1.00) and specificity 0.99 (95% CI 0.99-1.00). The other criteria showed lower agreement and diagnostic accuracy.</p><p><strong>Conclusions: </strong>The PHH major criterion showed near-perfect agreement and near-equal diagnostic accuracy compared with the gold standard method. This single criterion can be used as a short-form version to screen for PHH. Determination of reproducibility in independent populations is warranted.</p>\",\"PeriodicalId\":45914,\"journal\":{\"name\":\"Acta Dermatovenerologica Alpina Pannonica et Adriatica\",\"volume\":\"33 1\",\"pages\":\"17-22\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Dermatovenerologica Alpina Pannonica et Adriatica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DERMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Dermatovenerologica Alpina Pannonica et Adriatica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DERMATOLOGY","Score":null,"Total":0}
Diagnostic accuracy of a short-form version of the diagnostic criteria for primary hyperhidrosis.
Introduction: The gold standard method for diagnosing primary hyperhidrosis (PHH) is based on seven patient-reported criteria. By determining an individual criterion's diagnostic accuracy, one can identify short-version classification models.
Methods: In this cross-sectional study, data were collected from Danish blood donors in 2021. Cohen's kappa and diagnostic accuracy were determined by comparing each criterion with the gold standard method.
Results: The study included 1,039 participants. Of them, 59 (5.7%) had PHH and 980 (94.3%) were classified as control individuals. The PHH major criterion "focal visible excessive sweating for at least 6 months without an apparent cause" had the highest prevalence in the participants with PHH compared to the control individuals (100% vs. 0.6%; p < 0.0001). The agreement between this criterion and PHH was Cohen's kappa = 0.95 (95% confidence interval [CI] 0.91-0.99), and its sensitivity was 1.00 (95% CI 0.94-1.00) and specificity 0.99 (95% CI 0.99-1.00). The other criteria showed lower agreement and diagnostic accuracy.
Conclusions: The PHH major criterion showed near-perfect agreement and near-equal diagnostic accuracy compared with the gold standard method. This single criterion can be used as a short-form version to screen for PHH. Determination of reproducibility in independent populations is warranted.