{"title":"在青光眼引流装置手术后放置腔内缝合线以处理低位。","authors":"Minjia Tang, Anupama R Anchala, Angelo P Tanna","doi":"10.1097/IJG.0000000000002381","DOIUrl":null,"url":null,"abstract":"<p><strong>Prcis: </strong>Intraluminal 3-0 Supramid stent placement can be an effective long-term solution for hypotony after glaucoma drainage device surgery. This procedure may obviate the need for conjunctival dissection. In some cases, additional procedures are required.</p><p><strong>Purpose: </strong>To describe the utility of implantation of a multifilament polyamide suture (Supramid) in the tube lumen to reverse hypotony after glaucoma drainage device (GDD) surgery.</p><p><strong>Patients: </strong>Patients who underwent tube revision with intraluminal placement of a 3-0 Supramid stent, with or without external ligature, to manage hypotony following GDD surgery between January 2010 and October 2020.</p><p><strong>Methods: </strong>Resolution of hypotony was defined as IOP >5 mm Hg and the absence of hypotony-related structural abnormalities. Overall success was the absence of failure criteria (IOP ≤5 mm Hg, >21 mm Hg, or <20% reduction below baseline IOP after 3 months for 2 consecutive study visits; additional glaucoma surgery; or loss of light perception), with or without adjunctive ocular hypotensive therapy.</p><p><strong>Results: </strong>Nine eyes of 9 patients underwent placement of a 3-0 Supramid stent with a resolution of hypotony in all eyes with a mean follow-up duration of 33.3 ±24.0 months. Overall success was achieved in 7 of 9 eyes. Four eyes required intervention after stent placement: 1 eye required selective laser trabeculoplasty followed by replacement of the original stent with a shorter 3-0 Supramid suture and external ligature; 1 eye underwent revision for tube exposure; and 2 eyes underwent laser suture lysis to release an external suture ligature.</p><p><strong>Conclusions: </strong>In cases of hypotony after GDD, particularly when it is desirable to reduce the extent of additional conjunctival dissection, intraluminal placement of a 3-0 Supramid stent via an intracameral approach can be an effective long-term solution. Postoperative adjustments were required in many cases.</p>","PeriodicalId":15938,"journal":{"name":"Journal of Glaucoma","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intraluminal Suture Placement for Management of Hypotony After Glaucoma Drainage Device Surgery.\",\"authors\":\"Minjia Tang, Anupama R Anchala, Angelo P Tanna\",\"doi\":\"10.1097/IJG.0000000000002381\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Prcis: </strong>Intraluminal 3-0 Supramid stent placement can be an effective long-term solution for hypotony after glaucoma drainage device surgery. This procedure may obviate the need for conjunctival dissection. In some cases, additional procedures are required.</p><p><strong>Purpose: </strong>To describe the utility of implantation of a multifilament polyamide suture (Supramid) in the tube lumen to reverse hypotony after glaucoma drainage device (GDD) surgery.</p><p><strong>Patients: </strong>Patients who underwent tube revision with intraluminal placement of a 3-0 Supramid stent, with or without external ligature, to manage hypotony following GDD surgery between January 2010 and October 2020.</p><p><strong>Methods: </strong>Resolution of hypotony was defined as IOP >5 mm Hg and the absence of hypotony-related structural abnormalities. Overall success was the absence of failure criteria (IOP ≤5 mm Hg, >21 mm Hg, or <20% reduction below baseline IOP after 3 months for 2 consecutive study visits; additional glaucoma surgery; or loss of light perception), with or without adjunctive ocular hypotensive therapy.</p><p><strong>Results: </strong>Nine eyes of 9 patients underwent placement of a 3-0 Supramid stent with a resolution of hypotony in all eyes with a mean follow-up duration of 33.3 ±24.0 months. Overall success was achieved in 7 of 9 eyes. Four eyes required intervention after stent placement: 1 eye required selective laser trabeculoplasty followed by replacement of the original stent with a shorter 3-0 Supramid suture and external ligature; 1 eye underwent revision for tube exposure; and 2 eyes underwent laser suture lysis to release an external suture ligature.</p><p><strong>Conclusions: </strong>In cases of hypotony after GDD, particularly when it is desirable to reduce the extent of additional conjunctival dissection, intraluminal placement of a 3-0 Supramid stent via an intracameral approach can be an effective long-term solution. Postoperative adjustments were required in many cases.</p>\",\"PeriodicalId\":15938,\"journal\":{\"name\":\"Journal of Glaucoma\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Glaucoma\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/IJG.0000000000002381\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Glaucoma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IJG.0000000000002381","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Intraluminal Suture Placement for Management of Hypotony After Glaucoma Drainage Device Surgery.
Prcis: Intraluminal 3-0 Supramid stent placement can be an effective long-term solution for hypotony after glaucoma drainage device surgery. This procedure may obviate the need for conjunctival dissection. In some cases, additional procedures are required.
Purpose: To describe the utility of implantation of a multifilament polyamide suture (Supramid) in the tube lumen to reverse hypotony after glaucoma drainage device (GDD) surgery.
Patients: Patients who underwent tube revision with intraluminal placement of a 3-0 Supramid stent, with or without external ligature, to manage hypotony following GDD surgery between January 2010 and October 2020.
Methods: Resolution of hypotony was defined as IOP >5 mm Hg and the absence of hypotony-related structural abnormalities. Overall success was the absence of failure criteria (IOP ≤5 mm Hg, >21 mm Hg, or <20% reduction below baseline IOP after 3 months for 2 consecutive study visits; additional glaucoma surgery; or loss of light perception), with or without adjunctive ocular hypotensive therapy.
Results: Nine eyes of 9 patients underwent placement of a 3-0 Supramid stent with a resolution of hypotony in all eyes with a mean follow-up duration of 33.3 ±24.0 months. Overall success was achieved in 7 of 9 eyes. Four eyes required intervention after stent placement: 1 eye required selective laser trabeculoplasty followed by replacement of the original stent with a shorter 3-0 Supramid suture and external ligature; 1 eye underwent revision for tube exposure; and 2 eyes underwent laser suture lysis to release an external suture ligature.
Conclusions: In cases of hypotony after GDD, particularly when it is desirable to reduce the extent of additional conjunctival dissection, intraluminal placement of a 3-0 Supramid stent via an intracameral approach can be an effective long-term solution. Postoperative adjustments were required in many cases.