D N Okishev, An N Konovalov, A A Artemyev, E A Okisheva, Yu V Pilipenko, Sh Sh Eliava
{"title":"[用三种钛紧固件固定聚甲基丙烯酸甲酯颅骨植入体的比较]。","authors":"D N Okishev, An N Konovalov, A A Artemyev, E A Okisheva, Yu V Pilipenko, Sh Sh Eliava","doi":"10.17116/neiro20248802123","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate mechanical strength of three methods of polymethyl methacrylate skull implant fixation in two experimental models.</p><p><strong>Material and methods: </strong>The first experiment was performed on a plastic model that was as close as possible to bone in structural characteristics. The second experiment was performed on a biological specimen (a ram's head). We assessed the quality of implant fixation to bone window edges by craniofixes, ties and microscrews and lateral intercortical screws.</p><p><strong>Results: </strong>Craniofixes are feasible for small flat flaps, but not advisable for wide highly curved implants. They are also the most expensive method of fixation. Implant fixation by ties and microscrews is a universal method comparable in price to craniofix. Lateral intercortical fixation is effective both for small flat implants and wide implants with large curvature. However, this method is not always applicable.</p><p><strong>Conclusion: </strong>Combined fixation by lateral intercortical screws and ties allows for the most effective fixation while reducing the overall price of consumables.</p>","PeriodicalId":24032,"journal":{"name":"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko","volume":"88 2","pages":"23-30"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Comparison of polymethyl methacrylate skull implant fixation by three types of titanium fasteners].\",\"authors\":\"D N Okishev, An N Konovalov, A A Artemyev, E A Okisheva, Yu V Pilipenko, Sh Sh Eliava\",\"doi\":\"10.17116/neiro20248802123\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate mechanical strength of three methods of polymethyl methacrylate skull implant fixation in two experimental models.</p><p><strong>Material and methods: </strong>The first experiment was performed on a plastic model that was as close as possible to bone in structural characteristics. The second experiment was performed on a biological specimen (a ram's head). We assessed the quality of implant fixation to bone window edges by craniofixes, ties and microscrews and lateral intercortical screws.</p><p><strong>Results: </strong>Craniofixes are feasible for small flat flaps, but not advisable for wide highly curved implants. They are also the most expensive method of fixation. Implant fixation by ties and microscrews is a universal method comparable in price to craniofix. Lateral intercortical fixation is effective both for small flat implants and wide implants with large curvature. However, this method is not always applicable.</p><p><strong>Conclusion: </strong>Combined fixation by lateral intercortical screws and ties allows for the most effective fixation while reducing the overall price of consumables.</p>\",\"PeriodicalId\":24032,\"journal\":{\"name\":\"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko\",\"volume\":\"88 2\",\"pages\":\"23-30\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17116/neiro20248802123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/neiro20248802123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
[Comparison of polymethyl methacrylate skull implant fixation by three types of titanium fasteners].
Objective: To evaluate mechanical strength of three methods of polymethyl methacrylate skull implant fixation in two experimental models.
Material and methods: The first experiment was performed on a plastic model that was as close as possible to bone in structural characteristics. The second experiment was performed on a biological specimen (a ram's head). We assessed the quality of implant fixation to bone window edges by craniofixes, ties and microscrews and lateral intercortical screws.
Results: Craniofixes are feasible for small flat flaps, but not advisable for wide highly curved implants. They are also the most expensive method of fixation. Implant fixation by ties and microscrews is a universal method comparable in price to craniofix. Lateral intercortical fixation is effective both for small flat implants and wide implants with large curvature. However, this method is not always applicable.
Conclusion: Combined fixation by lateral intercortical screws and ties allows for the most effective fixation while reducing the overall price of consumables.
期刊介绍:
Scientific and practical peer-reviewed journal. This publication covers the theoretical, practical and organizational problems of modern neurosurgery, the latest advances in the treatment of various diseases of the central and peripheral nervous system. Founded in 1937. English version of the journal translates from Russian version since #1/2013.