首次使用 Dexter 机器人系统™进行比基尼线以下的机器人辅助子宫切除术。

IF 1.7 Q3 OBSTETRICS & GYNECOLOGY Facts Views and Vision in ObGyn Pub Date : 2024-03-01 DOI:10.52054/FVVO.16.1.010
I Alkatout, T Becker, P Nuhn, J Pochhammer, G Peters, K M Donald, L Mettler, J Ackermann
{"title":"首次使用 Dexter 机器人系统™进行比基尼线以下的机器人辅助子宫切除术。","authors":"I Alkatout, T Becker, P Nuhn, J Pochhammer, G Peters, K M Donald, L Mettler, J Ackermann","doi":"10.52054/FVVO.16.1.010","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Robotic-assisted hysterectomy (RAH) is a widely accepted minimally invasive approach for uterus removal. However, as RAH is typically performed in the umbilical region, it usually results in scars in cosmetically suboptimal locations. This is the first case of RAH with cervicosacropexy performed below the bikini line, using the new Dexter robotic system™.</p><p><strong>Objectives: </strong>The aim of this article is to show the surgical steps of the first RAH with cervicosacropexy performed below the bikini line with the new Dexter robotic system™ (Distalmotion), and furthermore assess the feasibility of this approach using this robotic platform.</p><p><strong>Materials and methods: </strong>A 43-year-old woman with uterine adenomyosis and recurrent uterine prolapse underwent a robotic-assisted subtotal hysterectomy with cervicosacropexy, performed below the bikini line, using the Dexter robotic system™, at the Clinic of Gynecology and Obstetrics at Universitätsklinikum Schleswig-Holstein (UKHS) in Kiel, Germany.</p><p><strong>Main outcome measures: </strong>Perioperative data, surgical approach specifics, objective, and subjective outcomes of this new approach.</p><p><strong>Results: </strong>The procedure was performed without intra-operative complications; estimated blood loss was 10 ml. Operative time was 150 minutes, console time 120 minutes, total docking time 6 minutes. Dexter performed as expected; no device-related issues or robotic arm collisions occurred. The patient did not require pain medication and was released on the second postoperative day.</p><p><strong>Conclusion: </strong>RAH performed below the bikini line using the Dexter robotic system™ is a feasible, safe, and adequate procedure. These initial results should be confirmed and further extensively refurbished with larger patient cohorts, and functional and psychological outcomes need further investigation.</p>","PeriodicalId":46400,"journal":{"name":"Facts Views and Vision in ObGyn","volume":"16 1","pages":"87-91"},"PeriodicalIF":1.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11198885/pdf/","citationCount":"0","resultStr":"{\"title\":\"The first robotic-assisted hysterectomy below the bikini line with the Dexter robotic system™.\",\"authors\":\"I Alkatout, T Becker, P Nuhn, J Pochhammer, G Peters, K M Donald, L Mettler, J Ackermann\",\"doi\":\"10.52054/FVVO.16.1.010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Robotic-assisted hysterectomy (RAH) is a widely accepted minimally invasive approach for uterus removal. However, as RAH is typically performed in the umbilical region, it usually results in scars in cosmetically suboptimal locations. This is the first case of RAH with cervicosacropexy performed below the bikini line, using the new Dexter robotic system™.</p><p><strong>Objectives: </strong>The aim of this article is to show the surgical steps of the first RAH with cervicosacropexy performed below the bikini line with the new Dexter robotic system™ (Distalmotion), and furthermore assess the feasibility of this approach using this robotic platform.</p><p><strong>Materials and methods: </strong>A 43-year-old woman with uterine adenomyosis and recurrent uterine prolapse underwent a robotic-assisted subtotal hysterectomy with cervicosacropexy, performed below the bikini line, using the Dexter robotic system™, at the Clinic of Gynecology and Obstetrics at Universitätsklinikum Schleswig-Holstein (UKHS) in Kiel, Germany.</p><p><strong>Main outcome measures: </strong>Perioperative data, surgical approach specifics, objective, and subjective outcomes of this new approach.</p><p><strong>Results: </strong>The procedure was performed without intra-operative complications; estimated blood loss was 10 ml. Operative time was 150 minutes, console time 120 minutes, total docking time 6 minutes. Dexter performed as expected; no device-related issues or robotic arm collisions occurred. The patient did not require pain medication and was released on the second postoperative day.</p><p><strong>Conclusion: </strong>RAH performed below the bikini line using the Dexter robotic system™ is a feasible, safe, and adequate procedure. These initial results should be confirmed and further extensively refurbished with larger patient cohorts, and functional and psychological outcomes need further investigation.</p>\",\"PeriodicalId\":46400,\"journal\":{\"name\":\"Facts Views and Vision in ObGyn\",\"volume\":\"16 1\",\"pages\":\"87-91\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11198885/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Facts Views and Vision in ObGyn\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52054/FVVO.16.1.010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Facts Views and Vision in ObGyn","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52054/FVVO.16.1.010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:机器人辅助子宫切除术(RAH)是一种广为接受的微创子宫切除术。然而,由于 RAH 通常在脐部区域进行,因此通常会在外观不理想的位置留下疤痕。本文是首例使用新型 Dexter 机器人系统™在比基尼线下进行 RAH 和宫颈骶骨切除术的病例:本文旨在展示首例使用新型 Dexter 机器人系统™(Distalmotion)在比基尼线下进行 RAH 伴颈骶骨切除术的手术步骤,并进一步评估使用该机器人平台进行该手术的可行性:一名患有子宫腺肌病和复发性子宫脱垂的43岁女性在德国基尔市石勒苏益格-荷尔斯泰因大学妇产科诊所(UKHS)接受了机器人辅助子宫次全切除术和宫颈骶骨切除术,手术在比基尼线下进行,使用的是Dexter机器人系统™:主要结果指标:围手术期数据、手术方法的具体细节、这种新方法的客观和主观结果:手术无术中并发症;估计失血量为 10 毫升。手术时间为 150 分钟,控制台时间为 120 分钟,总对接时间为 6 分钟。Dexter 的表现符合预期;没有发生与设备相关的问题或机械臂碰撞。患者无需服用止痛药,术后第二天即可出院:结论:使用 Dexter 机器人系统™ 在比基尼线下进行 RAH 是一种可行、安全且适当的手术。这些初步结果应在更大的患者群体中得到证实和进一步广泛的验证,功能和心理结果也需要进一步调查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The first robotic-assisted hysterectomy below the bikini line with the Dexter robotic system™.

Background: Robotic-assisted hysterectomy (RAH) is a widely accepted minimally invasive approach for uterus removal. However, as RAH is typically performed in the umbilical region, it usually results in scars in cosmetically suboptimal locations. This is the first case of RAH with cervicosacropexy performed below the bikini line, using the new Dexter robotic system™.

Objectives: The aim of this article is to show the surgical steps of the first RAH with cervicosacropexy performed below the bikini line with the new Dexter robotic system™ (Distalmotion), and furthermore assess the feasibility of this approach using this robotic platform.

Materials and methods: A 43-year-old woman with uterine adenomyosis and recurrent uterine prolapse underwent a robotic-assisted subtotal hysterectomy with cervicosacropexy, performed below the bikini line, using the Dexter robotic system™, at the Clinic of Gynecology and Obstetrics at Universitätsklinikum Schleswig-Holstein (UKHS) in Kiel, Germany.

Main outcome measures: Perioperative data, surgical approach specifics, objective, and subjective outcomes of this new approach.

Results: The procedure was performed without intra-operative complications; estimated blood loss was 10 ml. Operative time was 150 minutes, console time 120 minutes, total docking time 6 minutes. Dexter performed as expected; no device-related issues or robotic arm collisions occurred. The patient did not require pain medication and was released on the second postoperative day.

Conclusion: RAH performed below the bikini line using the Dexter robotic system™ is a feasible, safe, and adequate procedure. These initial results should be confirmed and further extensively refurbished with larger patient cohorts, and functional and psychological outcomes need further investigation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Facts Views and Vision in ObGyn
Facts Views and Vision in ObGyn OBSTETRICS & GYNECOLOGY-
自引率
15.00%
发文量
59
期刊最新文献
3D versus 4K laparoscopic vaginal cuff closure after hysterectomy by surgeons in training: a prospective randomised trial. Achieving successful outcomes with endometrial ablation needs better case selection. Author's response. Caesarean scar defect and retained products of conception (RPOC): a step-by-step combined hysteroscopic and laparoscopic treatment. Electrosurgery: heating, sparking and electrical arcs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1