重症监护警报疲劳与监护仪定制:警报频率和环境因素。

IF 2 4区 医学 Q3 CRITICAL CARE MEDICINE Critical care nurse Pub Date : 2024-04-01 DOI:10.4037/ccn2024797
Layla Z Arkilic, Elizabeth Hundt, Beth Quatrara
{"title":"重症监护警报疲劳与监护仪定制:警报频率和环境因素。","authors":"Layla Z Arkilic, Elizabeth Hundt, Beth Quatrara","doi":"10.4037/ccn2024797","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Alarm fatigue among nurses working in the intensive care unit has garnered considerable attention as a national patient safety priority. A viable solution for reducing the frequency of alarms and unnecessary noise is intensive care unit alarm monitor customization.</p><p><strong>Local problem: </strong>A 24-bed cardiovascular and thoracic surgery intensive care unit in a large academic medical center identified a high rate of alarms and associated noise as a problem contributing to nurse alarm fatigue.</p><p><strong>Methods: </strong>An alarm monitor quality improvement project used both alarm frequency and nurse surveys before and after implementation to determine the effectiveness of interventions. Multimodal interventions included nurse training sessions, informational flyers, organizational policies, and an alarm monitor training video. Unexpected results inspired an extensive investigation and secondary analysis, which included examining the data-capturing capabilities of the alarm monitors and the impact of context factors.</p><p><strong>Results: </strong>Alarm frequencies unexpectedly increased after the intervention. The software data-capturing features of the alarm monitors for determining frequency did not accurately measure nurse interactions with monitors. Measured increases in patient census, nurse staffing, and data input from medical devices from before to after the intervention substantially affected project results.</p><p><strong>Conclusions: </strong>Alarm frequencies proved an unreliable measure of nurse skills and practices in alarm customization. Documented changes in context factors provided strong anecdotal evidence of changed circumstances that clarified project results and underscored the critical importance of contemporaneous collection of context data. Designs and methods used in quality improvement projects must include reliable outcome measures to achieve meaningful results.</p>","PeriodicalId":10738,"journal":{"name":"Critical care nurse","volume":"44 2","pages":"21-30"},"PeriodicalIF":2.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Critical Care Alarm Fatigue and Monitor Customization: Alarm Frequencies and Context Factors.\",\"authors\":\"Layla Z Arkilic, Elizabeth Hundt, Beth Quatrara\",\"doi\":\"10.4037/ccn2024797\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Alarm fatigue among nurses working in the intensive care unit has garnered considerable attention as a national patient safety priority. A viable solution for reducing the frequency of alarms and unnecessary noise is intensive care unit alarm monitor customization.</p><p><strong>Local problem: </strong>A 24-bed cardiovascular and thoracic surgery intensive care unit in a large academic medical center identified a high rate of alarms and associated noise as a problem contributing to nurse alarm fatigue.</p><p><strong>Methods: </strong>An alarm monitor quality improvement project used both alarm frequency and nurse surveys before and after implementation to determine the effectiveness of interventions. Multimodal interventions included nurse training sessions, informational flyers, organizational policies, and an alarm monitor training video. Unexpected results inspired an extensive investigation and secondary analysis, which included examining the data-capturing capabilities of the alarm monitors and the impact of context factors.</p><p><strong>Results: </strong>Alarm frequencies unexpectedly increased after the intervention. The software data-capturing features of the alarm monitors for determining frequency did not accurately measure nurse interactions with monitors. Measured increases in patient census, nurse staffing, and data input from medical devices from before to after the intervention substantially affected project results.</p><p><strong>Conclusions: </strong>Alarm frequencies proved an unreliable measure of nurse skills and practices in alarm customization. Documented changes in context factors provided strong anecdotal evidence of changed circumstances that clarified project results and underscored the critical importance of contemporaneous collection of context data. Designs and methods used in quality improvement projects must include reliable outcome measures to achieve meaningful results.</p>\",\"PeriodicalId\":10738,\"journal\":{\"name\":\"Critical care nurse\",\"volume\":\"44 2\",\"pages\":\"21-30\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Critical care nurse\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4037/ccn2024797\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical care nurse","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4037/ccn2024797","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:重症监护室护士的警报疲劳问题已成为全国患者安全的首要问题,引起了广泛关注。当地问题:一家大型学术医疗中心的 24 张床位心血管和胸外科重症监护病房发现,高报警率和相关噪音是导致护士报警疲劳的一个问题:一个警报监控器质量改进项目在实施前后利用警报频率和护士调查来确定干预措施的效果。多模式干预措施包括护士培训课程、信息传单、组织政策和报警监控器培训视频。出乎意料的结果激发了广泛的调查和二次分析,其中包括检查报警监控器的数据采集能力和环境因素的影响:结果:干预后,报警频率意外增加。警报监测仪用于确定频率的软件数据采集功能并不能准确测量护士与监测仪之间的互动。干预前后,病人数量、护士人数和医疗设备数据输入的增加对项目结果产生了重大影响:事实证明,警报频率并不能可靠地衡量护士在警报定制方面的技能和实践。记录在案的环境因素变化为环境变化提供了有力的轶事证据,澄清了项目结果,并强调了同期环境数据收集的重要性。质量改进项目中使用的设计和方法必须包括可靠的结果测量,才能取得有意义的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Critical Care Alarm Fatigue and Monitor Customization: Alarm Frequencies and Context Factors.

Background: Alarm fatigue among nurses working in the intensive care unit has garnered considerable attention as a national patient safety priority. A viable solution for reducing the frequency of alarms and unnecessary noise is intensive care unit alarm monitor customization.

Local problem: A 24-bed cardiovascular and thoracic surgery intensive care unit in a large academic medical center identified a high rate of alarms and associated noise as a problem contributing to nurse alarm fatigue.

Methods: An alarm monitor quality improvement project used both alarm frequency and nurse surveys before and after implementation to determine the effectiveness of interventions. Multimodal interventions included nurse training sessions, informational flyers, organizational policies, and an alarm monitor training video. Unexpected results inspired an extensive investigation and secondary analysis, which included examining the data-capturing capabilities of the alarm monitors and the impact of context factors.

Results: Alarm frequencies unexpectedly increased after the intervention. The software data-capturing features of the alarm monitors for determining frequency did not accurately measure nurse interactions with monitors. Measured increases in patient census, nurse staffing, and data input from medical devices from before to after the intervention substantially affected project results.

Conclusions: Alarm frequencies proved an unreliable measure of nurse skills and practices in alarm customization. Documented changes in context factors provided strong anecdotal evidence of changed circumstances that clarified project results and underscored the critical importance of contemporaneous collection of context data. Designs and methods used in quality improvement projects must include reliable outcome measures to achieve meaningful results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Critical care nurse
Critical care nurse 医学-护理
CiteScore
2.80
自引率
0.00%
发文量
68
审稿时长
>12 weeks
期刊介绍: Critical Care Nurse (CCN) is an official publication of the American Association of Critical-Care Nurses (AACN). Authors are invited to submit manuscripts for consideration and peer review. Clinical topics must meet the mission of CCN and address nursing practice of acute and critically ill patients.
期刊最新文献
Assistive Communication Device Used During Pediatric Noninvasive Ventilation. Addressing Workplace Violence in Critical Care: A Call for Comprehensive Training and Support. Dental Hygienist Intervention to Prevent Ventilator-Associated Pneumonia in an Intensive Care Unit. Early Mobility After Cardiac Surgery: A Quality Improvement Project. Evidence-Based Approach to Appropriate Staffing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1