用于胎儿干预的肌肉注射胎儿麻醉鸡尾酒的稳定性和兼容性。

IF 1.6 3区 医学 Q3 OBSTETRICS & GYNECOLOGY Fetal Diagnosis and Therapy Pub Date : 2024-01-01 Epub Date: 2024-03-30 DOI:10.1159/000538611
Emma L Ross, Cristina L Wood, Michael F Wempe
{"title":"用于胎儿干预的肌肉注射胎儿麻醉鸡尾酒的稳定性和兼容性。","authors":"Emma L Ross, Cristina L Wood, Michael F Wempe","doi":"10.1159/000538611","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of the study was to evaluate chemical stability and physical compatibility when combining fentanyl, rocuronium, and atropine in a fixed ratio to support intramuscular drug delivery during fetal intervention and surgery.</p><p><strong>Methods: </strong>A highly concentrated combination of fentanyl, rocuronium, and atropine was created based on common prescribing practices at a maternal-fetal care center. Chemical stability testing was completed using liquid chromatograph mass spectrometry-mass spectrometry (LC/MS-MS) to detect and quantitate atropine, rocuronium, and fentanyl, with fentanyl-d5 being an internal standard at 6, 12, 24, and 36 h following sample preparation. Physical compatibility testing was completed using United States Pharmacopeia (USP) &lt;788&gt; recommended analytical technique of light obscuration in addition to novel backgrounded membrane imaging at 6 and 24 h following sample preparation. Physical compatibility was determined using USP &lt;788&gt; particle count limits for both techniques.</p><p><strong>Results: </strong>Based on LC/MS-MS results, the samples retained expected medication concentrations at all time points tested. For physical compatibility testing, the particle counts met criteria to be considered compatible per USP &lt;788&gt; large-volume particle count thresholds at 6 h by both methods but exceeded tolerable thresholds at 24 h.</p><p><strong>Discussion/conclusion: </strong>The combination of rocuronium, fentanyl, and atropine for intramuscular fetal administration is physically compatible and chemically stable for 6 h.</p>","PeriodicalId":12189,"journal":{"name":"Fetal Diagnosis and Therapy","volume":" ","pages":"313-319"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stability and Compatibility of an Intramuscular Fetal Anesthetic Cocktail for Fetal Intervention.\",\"authors\":\"Emma L Ross, Cristina L Wood, Michael F Wempe\",\"doi\":\"10.1159/000538611\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The aim of the study was to evaluate chemical stability and physical compatibility when combining fentanyl, rocuronium, and atropine in a fixed ratio to support intramuscular drug delivery during fetal intervention and surgery.</p><p><strong>Methods: </strong>A highly concentrated combination of fentanyl, rocuronium, and atropine was created based on common prescribing practices at a maternal-fetal care center. Chemical stability testing was completed using liquid chromatograph mass spectrometry-mass spectrometry (LC/MS-MS) to detect and quantitate atropine, rocuronium, and fentanyl, with fentanyl-d5 being an internal standard at 6, 12, 24, and 36 h following sample preparation. Physical compatibility testing was completed using United States Pharmacopeia (USP) &lt;788&gt; recommended analytical technique of light obscuration in addition to novel backgrounded membrane imaging at 6 and 24 h following sample preparation. Physical compatibility was determined using USP &lt;788&gt; particle count limits for both techniques.</p><p><strong>Results: </strong>Based on LC/MS-MS results, the samples retained expected medication concentrations at all time points tested. For physical compatibility testing, the particle counts met criteria to be considered compatible per USP &lt;788&gt; large-volume particle count thresholds at 6 h by both methods but exceeded tolerable thresholds at 24 h.</p><p><strong>Discussion/conclusion: </strong>The combination of rocuronium, fentanyl, and atropine for intramuscular fetal administration is physically compatible and chemically stable for 6 h.</p>\",\"PeriodicalId\":12189,\"journal\":{\"name\":\"Fetal Diagnosis and Therapy\",\"volume\":\" \",\"pages\":\"313-319\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fetal Diagnosis and Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000538611\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fetal Diagnosis and Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000538611","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

引言目的:评估芬太尼、罗库洛铵和阿托品按固定比例混合后的化学稳定性和物理相容性,以支持胎儿干预和手术过程中的肌肉给药:方法: 根据孕产妇胎儿护理中心的常见处方做法,制作了芬太尼、罗库洛铵和阿托品的高浓度组合。使用液相色谱-质谱法(LC/MS-MS)完成了化学稳定性测试,以检测和定量阿托品、罗库铵和芬太尼,并以芬太尼-d5 为内标,分别在样品制备后的 6、12、24 和 36 小时进行测试。物理兼容性测试采用美国药典 (USP) 推荐的光掩蔽 (LO) 分析技术以及新型背景膜成像 (BMI),分别在样品制备后 6 小时和 24 小时完成。两种技术的物理兼容性均采用 USP 粒子计数限值来确定:结果:根据 LC/MS-MS 结果,样品在所有测试时间点都保留了预期的药物浓度。在物理兼容性测试中,根据 USP 大容量粒子计数阈值,两种方法在 6 小时内的粒子计数均符合兼容性标准,但在 24 小时内超过了可容忍阈值:讨论/结论:用于胎儿肌肉注射的罗库溴铵、芬太尼和阿托品组合物在 6 小时内具有物理兼容性和化学稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stability and Compatibility of an Intramuscular Fetal Anesthetic Cocktail for Fetal Intervention.

Introduction: The aim of the study was to evaluate chemical stability and physical compatibility when combining fentanyl, rocuronium, and atropine in a fixed ratio to support intramuscular drug delivery during fetal intervention and surgery.

Methods: A highly concentrated combination of fentanyl, rocuronium, and atropine was created based on common prescribing practices at a maternal-fetal care center. Chemical stability testing was completed using liquid chromatograph mass spectrometry-mass spectrometry (LC/MS-MS) to detect and quantitate atropine, rocuronium, and fentanyl, with fentanyl-d5 being an internal standard at 6, 12, 24, and 36 h following sample preparation. Physical compatibility testing was completed using United States Pharmacopeia (USP) <788> recommended analytical technique of light obscuration in addition to novel backgrounded membrane imaging at 6 and 24 h following sample preparation. Physical compatibility was determined using USP <788> particle count limits for both techniques.

Results: Based on LC/MS-MS results, the samples retained expected medication concentrations at all time points tested. For physical compatibility testing, the particle counts met criteria to be considered compatible per USP <788> large-volume particle count thresholds at 6 h by both methods but exceeded tolerable thresholds at 24 h.

Discussion/conclusion: The combination of rocuronium, fentanyl, and atropine for intramuscular fetal administration is physically compatible and chemically stable for 6 h.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fetal Diagnosis and Therapy
Fetal Diagnosis and Therapy 医学-妇产科学
CiteScore
4.70
自引率
9.10%
发文量
48
审稿时长
6-12 weeks
期刊介绍: The first journal to focus on the fetus as a patient, ''Fetal Diagnosis and Therapy'' provides a wide range of biomedical specialists with a single source of reports encompassing the common discipline of fetal medicine.
期刊最新文献
First intrapartum sonographic diagnosis of fetal hypoxic ischemic encephalopathy (FHIE). Transplacental sirolimus for reversal of fetal heart failure due to fetal cardiac rhabdomyoma: fetal and maternal considerations. A rare case of dichorionic twins concordant for arterial tortuosity syndrome: case report and review of the literature. Reflections on the 40th IFMSS meeting Visby-Stockholm 2023. Fetal Extrahepatic Porto systemic Venous Shunts: prenatal diagnosis management and therapy: 21 years of evolving insights.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1