用于 PET 表面处理和减小接触角的紫外线臭氧发生器组件

IF 1.6 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Instrumentation & Measurement Magazine Pub Date : 2024-04-01 DOI:10.1109/MIM.2024.10473017
Havena Louise Pavan, Juscelino Valter Barbosas, Andreia Gerniski Macedo, Marco Aurélio Toledo da Silva, Carlos Eduardo Cava
{"title":"用于 PET 表面处理和减小接触角的紫外线臭氧发生器组件","authors":"Havena Louise Pavan, Juscelino Valter Barbosas, Andreia Gerniski Macedo, Marco Aurélio Toledo da Silva, Carlos Eduardo Cava","doi":"10.1109/MIM.2024.10473017","DOIUrl":null,"url":null,"abstract":"A low-cost UV-Ozone chamber showed promising results for improving adhesion on PET substrates. Exposure times and temperatures were applied, revealing that with 2 hours of exposure, the transmittance remained intact, and the contact angle was reduced by 30°. This process makes the PET substrate change from hydrophobic to hydrophilic, favoring the deposition of water-based materials. It was also proven, by FTIR analysis, that UV-Ozone exposure promotes permanent changes at ester and terephthalate groups on PET substrates. The AFM analysis demonstrated that the films' roughness significantly affects the substrates' hydrophilicity. The film's hydrophilic characteristics remain stable for more than 24 hours; however, a reduction of 15° is observed in the first hour after UV lighting is switched off.","PeriodicalId":55025,"journal":{"name":"IEEE Instrumentation & Measurement Magazine","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"UV-Ozone Chamber Assembled for Treatment and Contact Angle Reduction on PET Surfaces\",\"authors\":\"Havena Louise Pavan, Juscelino Valter Barbosas, Andreia Gerniski Macedo, Marco Aurélio Toledo da Silva, Carlos Eduardo Cava\",\"doi\":\"10.1109/MIM.2024.10473017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A low-cost UV-Ozone chamber showed promising results for improving adhesion on PET substrates. Exposure times and temperatures were applied, revealing that with 2 hours of exposure, the transmittance remained intact, and the contact angle was reduced by 30°. This process makes the PET substrate change from hydrophobic to hydrophilic, favoring the deposition of water-based materials. It was also proven, by FTIR analysis, that UV-Ozone exposure promotes permanent changes at ester and terephthalate groups on PET substrates. The AFM analysis demonstrated that the films' roughness significantly affects the substrates' hydrophilicity. The film's hydrophilic characteristics remain stable for more than 24 hours; however, a reduction of 15° is observed in the first hour after UV lighting is switched off.\",\"PeriodicalId\":55025,\"journal\":{\"name\":\"IEEE Instrumentation & Measurement Magazine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Instrumentation & Measurement Magazine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1109/MIM.2024.10473017\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Instrumentation & Measurement Magazine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/MIM.2024.10473017","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

低成本的紫外臭氧箱在改善 PET 基底的附着力方面显示出良好的效果。对曝光时间和温度的应用表明,曝光 2 小时后,透射率保持不变,接触角减少了 30°。这一过程使 PET 基底从疏水变为亲水,有利于水基材料的沉积。傅立叶变换红外光谱分析也证明,紫外臭氧照射会促进 PET 基底上的酯基和对苯二甲酸酯基发生永久性变化。原子力显微镜分析表明,薄膜的粗糙度对基底的亲水性有很大影响。薄膜的亲水特性在 24 小时内保持稳定,但在关闭紫外线照明后的第一个小时内,薄膜的亲水特性会降低 15°。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
UV-Ozone Chamber Assembled for Treatment and Contact Angle Reduction on PET Surfaces
A low-cost UV-Ozone chamber showed promising results for improving adhesion on PET substrates. Exposure times and temperatures were applied, revealing that with 2 hours of exposure, the transmittance remained intact, and the contact angle was reduced by 30°. This process makes the PET substrate change from hydrophobic to hydrophilic, favoring the deposition of water-based materials. It was also proven, by FTIR analysis, that UV-Ozone exposure promotes permanent changes at ester and terephthalate groups on PET substrates. The AFM analysis demonstrated that the films' roughness significantly affects the substrates' hydrophilicity. The film's hydrophilic characteristics remain stable for more than 24 hours; however, a reduction of 15° is observed in the first hour after UV lighting is switched off.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Instrumentation & Measurement Magazine
IEEE Instrumentation & Measurement Magazine 工程技术-工程:电子与电气
CiteScore
4.20
自引率
4.80%
发文量
147
审稿时长
>12 weeks
期刊介绍: IEEE Instrumentation & Measurement Magazine is a bimonthly publication. It publishes in February, April, June, August, October, and December of each year. The magazine covers a wide variety of topics in instrumentation, measurement, and systems that measure or instrument equipment or other systems. The magazine has the goal of providing readable introductions and overviews of technology in instrumentation and measurement to a wide engineering audience. It does this through articles, tutorials, columns, and departments. Its goal is to cross disciplines to encourage further research and development in instrumentation and measurement.
期刊最新文献
Diversity and Inclusion in I&M: IEEE Instrumentation and Measurement Mentorship Program Instrumentation and Measurement Systems: The Challenge of Designing Energy Harvesting Sensor Systems Simulation of a Fiber-Optic Bragg Sensor with a Tilted Grid Measurement Methodology: Breast Abnormality Detection using Thermography: An Engineer's Perspective Microwave Nondestructive Testing of Nonmetallic Pipes: An Overview of the Major Developments
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1