{"title":"使用各种仪器平行测定近视儿童客观调节参数的首次经验:寻找共同点","authors":"V. Neroev, E. Tarutta, S. E. Kondratova","doi":"10.21516/2072-0076-2024-17-1-32-39","DOIUrl":null,"url":null,"abstract":"Purpose: to study the relationship between the parameters of reflex and tonic accommodation measured using various objective methods.Material and methods. A comprehensive parallel study of objective accommodation parameters of 57 children (114 eyes) with low and moderate myopia (average -2.6 ± 1.4 D) aged from 8 to 12 years (average 9.9 ± 1.6 years) was carried out on three devices: Grand Seiko WAM-5500K, Acomoref 2 K-model Righton; TONOREF III, Nidek.Results. Both coincidences and differences of the indicators obtained by different methods as well as their correlations were revealed: positive - between the values of AR in the open field and in the virtual space (r = 0.23, r = 0.2); between the virtual responses to Righton K-2 and Nidek (r = 0.38); direct correlations of the accommodation response with accommodation tones. A correlation of average strength (r = 0.44) was found between the HAT on the Grand Seiko WR-5100K and the CMF on the Righton K2, which allows us to consider them as synonymous indicators. A negative relationship of CMF with PRA and SE refraction was found. A positive correlation of CMF with the rate of progression of myopia and a negative one with PRA suggests that a high CMF is a bad prognostic sign. However, CMF positively correlates with the magnitude of the accommodative response on all three devices. In this case, it turns out that an increase in CMF accompanies an increase in the amplitude of accommodation and, therefore, is not always a troublesome factor. Perhaps we are dealing with the limits of the norm for this indicator, which still need to be studied.Conclusion. With the help of objective methods of studying qualitatively different characteristics of one process, it is possible to investigate the actual and prognostic parameters of accommodation, which will allow us to offer an individualized approach to the treatment of patients with myopia using optical and drug instruments.","PeriodicalId":21436,"journal":{"name":"Russian Ophthalmological Journal","volume":" 7","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The first experience of parallel measurements of objective accommodation parameters in children with myopia using various instruments: in search of a common denominator\",\"authors\":\"V. Neroev, E. Tarutta, S. E. Kondratova\",\"doi\":\"10.21516/2072-0076-2024-17-1-32-39\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: to study the relationship between the parameters of reflex and tonic accommodation measured using various objective methods.Material and methods. A comprehensive parallel study of objective accommodation parameters of 57 children (114 eyes) with low and moderate myopia (average -2.6 ± 1.4 D) aged from 8 to 12 years (average 9.9 ± 1.6 years) was carried out on three devices: Grand Seiko WAM-5500K, Acomoref 2 K-model Righton; TONOREF III, Nidek.Results. Both coincidences and differences of the indicators obtained by different methods as well as their correlations were revealed: positive - between the values of AR in the open field and in the virtual space (r = 0.23, r = 0.2); between the virtual responses to Righton K-2 and Nidek (r = 0.38); direct correlations of the accommodation response with accommodation tones. A correlation of average strength (r = 0.44) was found between the HAT on the Grand Seiko WR-5100K and the CMF on the Righton K2, which allows us to consider them as synonymous indicators. A negative relationship of CMF with PRA and SE refraction was found. A positive correlation of CMF with the rate of progression of myopia and a negative one with PRA suggests that a high CMF is a bad prognostic sign. However, CMF positively correlates with the magnitude of the accommodative response on all three devices. In this case, it turns out that an increase in CMF accompanies an increase in the amplitude of accommodation and, therefore, is not always a troublesome factor. Perhaps we are dealing with the limits of the norm for this indicator, which still need to be studied.Conclusion. With the help of objective methods of studying qualitatively different characteristics of one process, it is possible to investigate the actual and prognostic parameters of accommodation, which will allow us to offer an individualized approach to the treatment of patients with myopia using optical and drug instruments.\",\"PeriodicalId\":21436,\"journal\":{\"name\":\"Russian Ophthalmological Journal\",\"volume\":\" 7\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Russian Ophthalmological Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21516/2072-0076-2024-17-1-32-39\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Ophthalmological Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21516/2072-0076-2024-17-1-32-39","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的:研究使用各种客观方法测量的反射性和调节性调节参数之间的关系。对 57 名 8 至 12 岁(平均 9.9 ± 1.6 岁)患有低度和中度近视(平均 -2.6 ± 1.4 D)的儿童(114 只眼)的客观调节参数进行了全面的平行研究:Grand Seiko WAM-5500K、Acomoref 2 K 型 Righton、TONOREF III、Nidek。通过不同方法获得的指标之间既有相同点,也有不同点,还存在相关性:开放空间和虚拟空间中的 AR 值之间存在正相关(r = 0.23,r = 0.2);Righton K-2 和 Nidek 的虚拟反应之间存在正相关(r = 0.38);调节反应与调节音调之间存在直接相关。Grand Seiko WR-5100K 上的 HAT 与 Righton K2 上的 CMF 之间存在平均强度的相关性(r = 0.44),因此我们可以将它们视为同义指标。CMF 与 PRA 和 SE 屈光度呈负相关。CMF 与近视发展速度呈正相关,而与 PRA 呈负相关,这表明高 CMF 是一个不好的预后信号。然而,CMF 与所有三种设备的适应反应幅度都呈正相关。在这种情况下,事实证明,CMF 的增加伴随着适应幅度的增加,因此并不总是一个麻烦的因素。也许我们正在处理的是这一指标的标准极限,这仍有待研究。借助研究一个过程的不同质量特征的客观方法,有可能研究出调节的实际参数和预后参数,这将使我们能够使用光学和药物仪器为近视患者提供个性化的治疗方法。
The first experience of parallel measurements of objective accommodation parameters in children with myopia using various instruments: in search of a common denominator
Purpose: to study the relationship between the parameters of reflex and tonic accommodation measured using various objective methods.Material and methods. A comprehensive parallel study of objective accommodation parameters of 57 children (114 eyes) with low and moderate myopia (average -2.6 ± 1.4 D) aged from 8 to 12 years (average 9.9 ± 1.6 years) was carried out on three devices: Grand Seiko WAM-5500K, Acomoref 2 K-model Righton; TONOREF III, Nidek.Results. Both coincidences and differences of the indicators obtained by different methods as well as their correlations were revealed: positive - between the values of AR in the open field and in the virtual space (r = 0.23, r = 0.2); between the virtual responses to Righton K-2 and Nidek (r = 0.38); direct correlations of the accommodation response with accommodation tones. A correlation of average strength (r = 0.44) was found between the HAT on the Grand Seiko WR-5100K and the CMF on the Righton K2, which allows us to consider them as synonymous indicators. A negative relationship of CMF with PRA and SE refraction was found. A positive correlation of CMF with the rate of progression of myopia and a negative one with PRA suggests that a high CMF is a bad prognostic sign. However, CMF positively correlates with the magnitude of the accommodative response on all three devices. In this case, it turns out that an increase in CMF accompanies an increase in the amplitude of accommodation and, therefore, is not always a troublesome factor. Perhaps we are dealing with the limits of the norm for this indicator, which still need to be studied.Conclusion. With the help of objective methods of studying qualitatively different characteristics of one process, it is possible to investigate the actual and prognostic parameters of accommodation, which will allow us to offer an individualized approach to the treatment of patients with myopia using optical and drug instruments.