评估测量结果:混合牙列正畸应用中数字模型和石膏模型的比较研究

Seo Young Shin, Y. Chae, Koeun Lee, Mi Sun Kim, O. Nam, Hyo-seol Lee, Sung Chul Choi
{"title":"评估测量结果:混合牙列正畸应用中数字模型和石膏模型的比较研究","authors":"Seo Young Shin, Y. Chae, Koeun Lee, Mi Sun Kim, O. Nam, Hyo-seol Lee, Sung Chul Choi","doi":"10.5933/jkapd.2024.51.1.55","DOIUrl":null,"url":null,"abstract":"This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.","PeriodicalId":22818,"journal":{"name":"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition\",\"authors\":\"Seo Young Shin, Y. Chae, Koeun Lee, Mi Sun Kim, O. Nam, Hyo-seol Lee, Sung Chul Choi\",\"doi\":\"10.5933/jkapd.2024.51.1.55\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.\",\"PeriodicalId\":22818,\"journal\":{\"name\":\"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5933/jkapd.2024.51.1.55\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5933/jkapd.2024.51.1.55","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估通过两种口内扫描仪(包括 iTero Element Plus 系列(Align Technology,美国加利福尼亚州圣克拉拉市)和 Trios 4(3Shape,丹麦哥本哈根市))获得的牙齿宽度、磨牙间宽度和牙弓长度的准确性,特别是对混合牙的准确性。共有 30 名受试者被分为两组,每组都使用 iTero 或 Trios 扫描仪进行藻酸盐印模和口内扫描。石膏模型是用卡尺测量的,而数字模型则是虚拟测量的。在 iTero 组,除了上颌左侧切牙(p = 0.179)、下颌右侧切牙(p = 0.285)和左侧中切牙(p = 0.073)外,所有牙齿宽度测量值与石膏值相比都有差异。Trios 组在任何牙齿宽度测量中均未显示出显著差异。除了 iTero 组的下颌主犬齿与主犬齿值(p = 0.426)外,两组的磨间宽度比较均显示出差异。在牙弓长度方面,iTero 组的下颌前弓、上颌右弓和左弓长度的卡尺值均大于 iTero 组。相反,在 Trios 组,所有参数的卡尺值都较小,尤其是上前牙弓、上颌右弓、下颌右弓和下颌左弓的卡尺值显著(p = 0.027、0.007、0.003 和 0.047)。尽管两组之间存在差异,但数字模型在临床上可能是石膏模型的合适替代品。儿童牙医应仔细评估这些差异,因为全面的评估将为混合牙列的年轻患者带来精确的正畸治疗计划和良好的治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition
This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical Usefulness of the Jones Jig Appliance for Alignment of Premolars and Molars: Case Reports Managing Short Root Anomalies in Pediatric Cancer Survivors: Utilizing Resin Wire Splints and Miniscrews for Skeletal Anchorage Deep Learning in Dental Radiographic Imaging Enhancing the Antibacterial Effect of Erythrosine-Mediated Photodynamic Therapy with Ethylenediamine Tetraacetic Acid Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1