{"title":"从乳腺炎牛乳中提取的 DNA 洗脱液中携带的磁珠","authors":"Mohammed Farah Mohammed Abdelhamed, Rania Hassan Zaid, Mohamed T. Ibrahim, Ahmed Eltigani Almansoori","doi":"10.20546/ijcmas.2024.1301.009","DOIUrl":null,"url":null,"abstract":"Using the magnetic separation technique in nucleic acid extraction is considered one of the most rabid and easy automated extraction methods that use minimal amounts of equipment. This paper describes some cow-related factors that may affect the carrying of magnetic beads during the extraction process. A total of 85 milk samples were collected from clinically infected cows with mastitis. DNA extraction is done using the Mag MAX™ CORE Nucleic Acid Purification Kit and the King Fisher™ Duo Prime Purification System. Fifty-three (62.4%) samples are extracted normally, while thirty-two (37.6%) have a magnetic bead carried over, and two (6.3%) out of the thirty-two supernatant DNA samples can’t be collected. To evaluate the impact of lactation, frequency of mastitis, days in milk, and gestation period on magnetic beads carried over during DNA extraction when using the magnetic separation technique, a Chi-square test of independence was performed, and it showed that there was no significant association between magnetic beads carried over and lactation (Chi square = 0.28, P = 0.60), frequency of mastitis (Chi square = 2.26, P = 0.13), days in milk (Chi square = 0.84, P = 0.66), and gestation period (Chi square = 4.24, P = 0.12). Therefore, more studies need to be conducted to interpret this phenomenon.","PeriodicalId":13777,"journal":{"name":"International Journal of Current Microbiology and Applied Sciences","volume":"86 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Magnetic Beads Carried Over in Extracted DNA Elution from Mastitis Cow Milk\",\"authors\":\"Mohammed Farah Mohammed Abdelhamed, Rania Hassan Zaid, Mohamed T. Ibrahim, Ahmed Eltigani Almansoori\",\"doi\":\"10.20546/ijcmas.2024.1301.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using the magnetic separation technique in nucleic acid extraction is considered one of the most rabid and easy automated extraction methods that use minimal amounts of equipment. This paper describes some cow-related factors that may affect the carrying of magnetic beads during the extraction process. A total of 85 milk samples were collected from clinically infected cows with mastitis. DNA extraction is done using the Mag MAX™ CORE Nucleic Acid Purification Kit and the King Fisher™ Duo Prime Purification System. Fifty-three (62.4%) samples are extracted normally, while thirty-two (37.6%) have a magnetic bead carried over, and two (6.3%) out of the thirty-two supernatant DNA samples can’t be collected. To evaluate the impact of lactation, frequency of mastitis, days in milk, and gestation period on magnetic beads carried over during DNA extraction when using the magnetic separation technique, a Chi-square test of independence was performed, and it showed that there was no significant association between magnetic beads carried over and lactation (Chi square = 0.28, P = 0.60), frequency of mastitis (Chi square = 2.26, P = 0.13), days in milk (Chi square = 0.84, P = 0.66), and gestation period (Chi square = 4.24, P = 0.12). Therefore, more studies need to be conducted to interpret this phenomenon.\",\"PeriodicalId\":13777,\"journal\":{\"name\":\"International Journal of Current Microbiology and Applied Sciences\",\"volume\":\"86 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Current Microbiology and Applied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20546/ijcmas.2024.1301.009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Current Microbiology and Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20546/ijcmas.2024.1301.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在核酸提取中使用磁分离技术被认为是最狂热、最简单、使用设备最少的自动化提取方法之一。本文介绍了提取过程中可能影响磁珠携带的一些奶牛相关因素。从临床感染乳腺炎的奶牛身上共采集了 85 份牛奶样本。使用 Mag MAX™ CORE 核酸纯化试剂盒和 King Fisher™ Duo Prime 纯化系统进行 DNA 提取。53个样本(62.4%)提取正常,32个样本(37.6%)有磁珠残留,32个上清液DNA样本中有2个样本(6.3%)无法收集。为了评估使用磁分离技术提取 DNA 时泌乳期、乳腺炎频率、产奶天数和妊娠期对磁珠携带量的影响,进行了独立性 Chi-square 检验,结果表明磁珠携带量与泌乳期无显著关联(Chi square = 0.28,P = 0.60)、乳腺炎频率(Chi square = 2.26,P = 0.13)、在乳天数(Chi square = 0.84,P = 0.66)和妊娠期(Chi square = 4.24,P = 0.12)之间没有明显关联。因此,需要进行更多的研究来解释这一现象。
Magnetic Beads Carried Over in Extracted DNA Elution from Mastitis Cow Milk
Using the magnetic separation technique in nucleic acid extraction is considered one of the most rabid and easy automated extraction methods that use minimal amounts of equipment. This paper describes some cow-related factors that may affect the carrying of magnetic beads during the extraction process. A total of 85 milk samples were collected from clinically infected cows with mastitis. DNA extraction is done using the Mag MAX™ CORE Nucleic Acid Purification Kit and the King Fisher™ Duo Prime Purification System. Fifty-three (62.4%) samples are extracted normally, while thirty-two (37.6%) have a magnetic bead carried over, and two (6.3%) out of the thirty-two supernatant DNA samples can’t be collected. To evaluate the impact of lactation, frequency of mastitis, days in milk, and gestation period on magnetic beads carried over during DNA extraction when using the magnetic separation technique, a Chi-square test of independence was performed, and it showed that there was no significant association between magnetic beads carried over and lactation (Chi square = 0.28, P = 0.60), frequency of mastitis (Chi square = 2.26, P = 0.13), days in milk (Chi square = 0.84, P = 0.66), and gestation period (Chi square = 4.24, P = 0.12). Therefore, more studies need to be conducted to interpret this phenomenon.