Liberty® by Medicontur,一种结构复杂的亲水性眼内透镜,用于矫正术前近视眼

Adam Cywiński, Paulina Bazgier
{"title":"Liberty® by Medicontur,一种结构复杂的亲水性眼内透镜,用于矫正术前近视眼","authors":"Adam Cywiński, Paulina Bazgier","doi":"10.26420/austinjclinopthalmol.2024.1173","DOIUrl":null,"url":null,"abstract":"A retrospective analysis of visual function in patients with preoperatively diagnosed myopia, after implantation of Liberty® intraocular lens, including the influence of some factors like a kind of surgery, values of angle alpha and kappa, pupil size, values of higher order aberrations generated by the lens on visual acuity to far and near distances was done. Lens removal and Liberty® implantation was done 47 eyes, including in 13 patients in both eyes. In 7 eyes, it was a toric lens. A mean preoperative value of myopia was -6.72 Dsph. Cataract removal accounted for 55% of all procedures performed, the rest being Refractive Lens Exchange. Preoperative pupil size was between 3.6 and 6,4 mm. The average postoperative visual acuity to far distances was 0.13 (logMar), and to near distances was 0.51 (Snellen). Rare cases of insufficient quality of vision to intermediate distances, when the postoperative pupil size was greater than 4 mm, resolved after increasing light intensity in the room. A bigger values of higher order aberrations corresponded with lower values of preoperative visual acuity to far distances. A bigger values of angle alpha corresponded with lower values of postoperative visual acuity to far distances, which were significantly higher in cataract group. Visual acuity to far distances was also better in eye with bigger pupil size. A specific structure of the lens allows patients to see good to the near distances, even if the light intensity not perfect.","PeriodicalId":90447,"journal":{"name":"Austin journal of clinical ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Liberty® by Medicontur, a Complex in Structure, Hydrophilic Intraocular Lens in the Correction of Eyes with Preoperative Myopia\",\"authors\":\"Adam Cywiński, Paulina Bazgier\",\"doi\":\"10.26420/austinjclinopthalmol.2024.1173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A retrospective analysis of visual function in patients with preoperatively diagnosed myopia, after implantation of Liberty® intraocular lens, including the influence of some factors like a kind of surgery, values of angle alpha and kappa, pupil size, values of higher order aberrations generated by the lens on visual acuity to far and near distances was done. Lens removal and Liberty® implantation was done 47 eyes, including in 13 patients in both eyes. In 7 eyes, it was a toric lens. A mean preoperative value of myopia was -6.72 Dsph. Cataract removal accounted for 55% of all procedures performed, the rest being Refractive Lens Exchange. Preoperative pupil size was between 3.6 and 6,4 mm. The average postoperative visual acuity to far distances was 0.13 (logMar), and to near distances was 0.51 (Snellen). Rare cases of insufficient quality of vision to intermediate distances, when the postoperative pupil size was greater than 4 mm, resolved after increasing light intensity in the room. A bigger values of higher order aberrations corresponded with lower values of preoperative visual acuity to far distances. A bigger values of angle alpha corresponded with lower values of postoperative visual acuity to far distances, which were significantly higher in cataract group. Visual acuity to far distances was also better in eye with bigger pupil size. A specific structure of the lens allows patients to see good to the near distances, even if the light intensity not perfect.\",\"PeriodicalId\":90447,\"journal\":{\"name\":\"Austin journal of clinical ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Austin journal of clinical ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26420/austinjclinopthalmol.2024.1173\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Austin journal of clinical ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/austinjclinopthalmol.2024.1173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

该研究对术前诊断为近视的患者在植入自由曲面人工晶体后的视觉功能进行了回顾性分析,其中包括一些因素对远近距离视力的影响,如手术类型、α角和卡帕角值、瞳孔大小、人工晶体产生的高阶像差值等。共完成了 47 眼晶状体摘除和 Liberty® 人工晶体植入手术,其中 13 名患者双眼均接受了手术。其中 7 只眼睛植入了散光透镜。术前近视的平均值为-6.72 Dsph。白内障摘除术占所有手术的 55%,其余为屈光晶体置换术。术前瞳孔大小在 3.6 至 6.4 毫米之间。术后远距离平均视力为 0.13(logMar),近距离平均视力为 0.51(斯奈伦)。当术后瞳孔大于 4 毫米时,极少数中距离视力不足的情况会在室内光照强度增加后得到缓解。高阶像差值越大,术前远距离视力值越低。α角值越大,术后远距离视力值越低,白内障组的术后远距离视力值明显更高。瞳孔较大的眼睛远距离视力也较好。晶状体的特殊结构使患者即使在光线强度不完美的情况下也能看清近处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Liberty® by Medicontur, a Complex in Structure, Hydrophilic Intraocular Lens in the Correction of Eyes with Preoperative Myopia
A retrospective analysis of visual function in patients with preoperatively diagnosed myopia, after implantation of Liberty® intraocular lens, including the influence of some factors like a kind of surgery, values of angle alpha and kappa, pupil size, values of higher order aberrations generated by the lens on visual acuity to far and near distances was done. Lens removal and Liberty® implantation was done 47 eyes, including in 13 patients in both eyes. In 7 eyes, it was a toric lens. A mean preoperative value of myopia was -6.72 Dsph. Cataract removal accounted for 55% of all procedures performed, the rest being Refractive Lens Exchange. Preoperative pupil size was between 3.6 and 6,4 mm. The average postoperative visual acuity to far distances was 0.13 (logMar), and to near distances was 0.51 (Snellen). Rare cases of insufficient quality of vision to intermediate distances, when the postoperative pupil size was greater than 4 mm, resolved after increasing light intensity in the room. A bigger values of higher order aberrations corresponded with lower values of preoperative visual acuity to far distances. A bigger values of angle alpha corresponded with lower values of postoperative visual acuity to far distances, which were significantly higher in cataract group. Visual acuity to far distances was also better in eye with bigger pupil size. A specific structure of the lens allows patients to see good to the near distances, even if the light intensity not perfect.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Liberty® by Medicontur, a Complex in Structure, Hydrophilic Intraocular Lens in the Correction of Eyes with Preoperative Myopia Cataract and Celiac Disease Cerulean Cataract Bilateral Anterior Crystalline Lens Dislocation Reveals Homocystinuria Both Central Retinal Venous Occlusion and Cilioretinal Artery Occlusion Secondary to Hyperhomocysteinemia. A Case Report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1