Florian Dobler, Robin Mayr, Harald Lengnick, Peter Federolf, Nathalie Alexander
{"title":"铰链式和碳纤维踝足矫形器对单侧痉挛性脑瘫和垂足步态儿童的疗效","authors":"Florian Dobler, Robin Mayr, Harald Lengnick, Peter Federolf, Nathalie Alexander","doi":"10.1097/pxr.0000000000000337","DOIUrl":null,"url":null,"abstract":"Background: In children with unilateral spastic cerebral palsy (USCP), ankle-foot orthoses (AFOs) are widely used to correct common gait deviations such as a drop-foot pattern. Most studies on this topic have investigated specific time points while omitting other parts of the gait cycle. Objectives: This study investigated the separate effects of prefabricated carbon fiber AFOs and custom-made hinged AFOs compared with barefoot walking in children with USCP with a drop-foot gait pattern using statistical parametric mapping. Study design: Retrospective, cross-sectional, repeated measures study. Methods: Twenty ambulatory children (9.9 ± 2.5 years) with USCP and a drop-foot gait pattern were included. Kinematics, kinetics, and spatiotemporal parameters assessed during 3-dimensional gait analysis were compared between barefoot and AFO walking. Statistical parametric mapping was used to compare joint angles and moment waveforms. Kinematics, kinetics and spatiotemporal parameters assessed during 3-dimensional gait analysis were compared between barefoot and AFO walking for each AFO type but not between the 2 AFO types. Results: Compared with barefoot walking, there was a steeper sole angle at initial contact, corresponding to a heel strike pattern, and an increased ankle dorsiflexion in swing with the use of both AFOs. The ankle plantar flexion moment during loading response increased. Ankle power generation during pre-swing decreased in the carbon fiber AFO group when walking with AFOs. Conclusions: Both AFOs were beneficial for improving a drop-foot gait pattern in these small patient groups and can, therefore, be recommended to treat this gait deviation in patients with unilateral cerebral palsy. However, the reduction in ankle power generation during push-off and additional goals targeted by AFOs, such as correction of structural or flexible foot deformities, should be considered for prescription.","PeriodicalId":49657,"journal":{"name":"Prosthetics and Orthotics International","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Efficacy of hinged and carbon fiber ankle-foot orthoses in children with unilateral spastic cerebral palsy and drop-foot gait pattern\",\"authors\":\"Florian Dobler, Robin Mayr, Harald Lengnick, Peter Federolf, Nathalie Alexander\",\"doi\":\"10.1097/pxr.0000000000000337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: In children with unilateral spastic cerebral palsy (USCP), ankle-foot orthoses (AFOs) are widely used to correct common gait deviations such as a drop-foot pattern. Most studies on this topic have investigated specific time points while omitting other parts of the gait cycle. Objectives: This study investigated the separate effects of prefabricated carbon fiber AFOs and custom-made hinged AFOs compared with barefoot walking in children with USCP with a drop-foot gait pattern using statistical parametric mapping. Study design: Retrospective, cross-sectional, repeated measures study. Methods: Twenty ambulatory children (9.9 ± 2.5 years) with USCP and a drop-foot gait pattern were included. Kinematics, kinetics, and spatiotemporal parameters assessed during 3-dimensional gait analysis were compared between barefoot and AFO walking. Statistical parametric mapping was used to compare joint angles and moment waveforms. Kinematics, kinetics and spatiotemporal parameters assessed during 3-dimensional gait analysis were compared between barefoot and AFO walking for each AFO type but not between the 2 AFO types. Results: Compared with barefoot walking, there was a steeper sole angle at initial contact, corresponding to a heel strike pattern, and an increased ankle dorsiflexion in swing with the use of both AFOs. The ankle plantar flexion moment during loading response increased. Ankle power generation during pre-swing decreased in the carbon fiber AFO group when walking with AFOs. Conclusions: Both AFOs were beneficial for improving a drop-foot gait pattern in these small patient groups and can, therefore, be recommended to treat this gait deviation in patients with unilateral cerebral palsy. However, the reduction in ankle power generation during push-off and additional goals targeted by AFOs, such as correction of structural or flexible foot deformities, should be considered for prescription.\",\"PeriodicalId\":49657,\"journal\":{\"name\":\"Prosthetics and Orthotics International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Prosthetics and Orthotics International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/pxr.0000000000000337\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prosthetics and Orthotics International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/pxr.0000000000000337","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
背景:在单侧痉挛性脑瘫(USCP)患儿中,踝足矫形器(AFO)被广泛用于矫正常见的步态偏差,如跌足模式。有关这一主题的大多数研究都对特定的时间点进行了调查,而忽略了步态周期的其他部分。研究目的本研究采用统计参数图法,调查了预制碳纤维 AFO 和定制铰链式 AFO 与赤足行走相比,对具有垂足步态的 USCP 儿童的不同影响。研究设计:回顾性、横断面、重复测量研究。研究方法:纳入 20 名患有 USCP 和垂足步态的儿童(9.9 ± 2.5 岁)。在三维步态分析过程中评估的运动学、动力学和时空参数对赤足行走和AFO行走进行了比较。统计参数绘图用于比较关节角度和力矩波形。在三维步态分析过程中评估的运动学、动力学和时空参数在每种AFO类型的赤足行走和AFO行走之间进行了比较,但没有在两种AFO类型之间进行比较。结果:与赤足行走相比,使用两种AFO时,初始接触时的鞋底角度更陡,相当于脚跟着地模式,摆动时的踝关节背屈增加。加载响应时的踝关节跖屈力矩增加。碳纤维 AFO 组在使用 AFO 步行时,踝关节在挥杆前的发力有所下降。结论:两种 AFO 均有利于改善这些小患者群体的垂足步态,因此可推荐用于治疗单侧脑瘫患者的这种步态偏差。不过,在开处方时应考虑到推起时踝关节发力的减少以及 AFOs 的其他目标,如矫正足部结构性或柔性畸形。
Efficacy of hinged and carbon fiber ankle-foot orthoses in children with unilateral spastic cerebral palsy and drop-foot gait pattern
Background: In children with unilateral spastic cerebral palsy (USCP), ankle-foot orthoses (AFOs) are widely used to correct common gait deviations such as a drop-foot pattern. Most studies on this topic have investigated specific time points while omitting other parts of the gait cycle. Objectives: This study investigated the separate effects of prefabricated carbon fiber AFOs and custom-made hinged AFOs compared with barefoot walking in children with USCP with a drop-foot gait pattern using statistical parametric mapping. Study design: Retrospective, cross-sectional, repeated measures study. Methods: Twenty ambulatory children (9.9 ± 2.5 years) with USCP and a drop-foot gait pattern were included. Kinematics, kinetics, and spatiotemporal parameters assessed during 3-dimensional gait analysis were compared between barefoot and AFO walking. Statistical parametric mapping was used to compare joint angles and moment waveforms. Kinematics, kinetics and spatiotemporal parameters assessed during 3-dimensional gait analysis were compared between barefoot and AFO walking for each AFO type but not between the 2 AFO types. Results: Compared with barefoot walking, there was a steeper sole angle at initial contact, corresponding to a heel strike pattern, and an increased ankle dorsiflexion in swing with the use of both AFOs. The ankle plantar flexion moment during loading response increased. Ankle power generation during pre-swing decreased in the carbon fiber AFO group when walking with AFOs. Conclusions: Both AFOs were beneficial for improving a drop-foot gait pattern in these small patient groups and can, therefore, be recommended to treat this gait deviation in patients with unilateral cerebral palsy. However, the reduction in ankle power generation during push-off and additional goals targeted by AFOs, such as correction of structural or flexible foot deformities, should be considered for prescription.
期刊介绍:
Prosthetics and Orthotics International is an international, multidisciplinary journal for all professionals who have an interest in the medical, clinical, rehabilitation, technical, educational and research aspects of prosthetics, orthotics and rehabilitation engineering, as well as their related topics.