用于测定人体唾液中硫氰酸盐的纳米结构酞菁修饰丝网印刷电极

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL Electroanalysis Pub Date : 2024-04-05 DOI:10.1002/elan.202400011
Vit Pavelka, Alexandros Ch. Lazanas, Myrto Sarigiannidou, Jan Hrbac, Mamas I. Prodromidis
{"title":"用于测定人体唾液中硫氰酸盐的纳米结构酞菁修饰丝网印刷电极","authors":"Vit Pavelka,&nbsp;Alexandros Ch. Lazanas,&nbsp;Myrto Sarigiannidou,&nbsp;Jan Hrbac,&nbsp;Mamas I. Prodromidis","doi":"10.1002/elan.202400011","DOIUrl":null,"url":null,"abstract":"<p>Salivary thiocyanate is a biomarker of individual health that notably allows for the discrimination between smokers and non-smokers. Recent studies have also demonstrated its potential as a biomarker of cystic fibrosis, thus rendering the development of methods for its determination in saliva of immense importance. In response, we report on the development of graphite screen-printed electrodes (SPE) modified with cobalt(II) phthalocyanine nanosticks (CoPcNst), as low-cost and semi-disposable sensors for the determination of thiocyanate ion (SCN<sup>−</sup>) in human saliva. CoPCNst were synthesized and characterized using scanning electron microscopy, x-ray diffraction, as well as infrared and Raman spectroscopies. The results revealed a structural proximity to the recently identified J-polymorph. Compared with the electrode modified with commercial, beta-structure cobalt(II) phthalocyanine, the CoPc Nst/SPE provided four times better LOD and LOQ (0.49 and 1.62 μM) for thiocyanate determination by differential pulse voltammetry. The response was linear up to 20 μM SCN− (R2=0.996) and it was not affected by excess of common electro active compounds, such as ascorbic and uric acid. The analytical utility of CoPc Nst/SPE in human saliva is demonstrated.</p>","PeriodicalId":162,"journal":{"name":"Electroanalysis","volume":"36 10","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nanostructured cobalt(II) phthalocyanine modified screen-printed electrodes for the determination of thiocyanate in human saliva\",\"authors\":\"Vit Pavelka,&nbsp;Alexandros Ch. Lazanas,&nbsp;Myrto Sarigiannidou,&nbsp;Jan Hrbac,&nbsp;Mamas I. Prodromidis\",\"doi\":\"10.1002/elan.202400011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Salivary thiocyanate is a biomarker of individual health that notably allows for the discrimination between smokers and non-smokers. Recent studies have also demonstrated its potential as a biomarker of cystic fibrosis, thus rendering the development of methods for its determination in saliva of immense importance. In response, we report on the development of graphite screen-printed electrodes (SPE) modified with cobalt(II) phthalocyanine nanosticks (CoPcNst), as low-cost and semi-disposable sensors for the determination of thiocyanate ion (SCN<sup>−</sup>) in human saliva. CoPCNst were synthesized and characterized using scanning electron microscopy, x-ray diffraction, as well as infrared and Raman spectroscopies. The results revealed a structural proximity to the recently identified J-polymorph. Compared with the electrode modified with commercial, beta-structure cobalt(II) phthalocyanine, the CoPc Nst/SPE provided four times better LOD and LOQ (0.49 and 1.62 μM) for thiocyanate determination by differential pulse voltammetry. The response was linear up to 20 μM SCN− (R2=0.996) and it was not affected by excess of common electro active compounds, such as ascorbic and uric acid. The analytical utility of CoPc Nst/SPE in human saliva is demonstrated.</p>\",\"PeriodicalId\":162,\"journal\":{\"name\":\"Electroanalysis\",\"volume\":\"36 10\",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electroanalysis\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/elan.202400011\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroanalysis","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/elan.202400011","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

NA
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Nanostructured cobalt(II) phthalocyanine modified screen-printed electrodes for the determination of thiocyanate in human saliva

Salivary thiocyanate is a biomarker of individual health that notably allows for the discrimination between smokers and non-smokers. Recent studies have also demonstrated its potential as a biomarker of cystic fibrosis, thus rendering the development of methods for its determination in saliva of immense importance. In response, we report on the development of graphite screen-printed electrodes (SPE) modified with cobalt(II) phthalocyanine nanosticks (CoPcNst), as low-cost and semi-disposable sensors for the determination of thiocyanate ion (SCN) in human saliva. CoPCNst were synthesized and characterized using scanning electron microscopy, x-ray diffraction, as well as infrared and Raman spectroscopies. The results revealed a structural proximity to the recently identified J-polymorph. Compared with the electrode modified with commercial, beta-structure cobalt(II) phthalocyanine, the CoPc Nst/SPE provided four times better LOD and LOQ (0.49 and 1.62 μM) for thiocyanate determination by differential pulse voltammetry. The response was linear up to 20 μM SCN− (R2=0.996) and it was not affected by excess of common electro active compounds, such as ascorbic and uric acid. The analytical utility of CoPc Nst/SPE in human saliva is demonstrated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electroanalysis
Electroanalysis 化学-电化学
CiteScore
6.00
自引率
3.30%
发文量
222
审稿时长
2.4 months
期刊介绍: Electroanalysis is an international, peer-reviewed journal covering all branches of electroanalytical chemistry, including both fundamental and application papers as well as reviews dealing with new electrochemical sensors and biosensors, nanobioelectronics devices, analytical voltammetry, potentiometry, new electrochemical detection schemes based on novel nanomaterials, fuel cells and biofuel cells, and important practical applications. Serving as a vital communication link between the research labs and the field, Electroanalysis helps you to quickly adapt the latest innovations into practical clinical, environmental, food analysis, industrial and energy-related applications. Electroanalysis provides the most comprehensive coverage of the field and is the number one source for information on electroanalytical chemistry, electrochemical sensors and biosensors and fuel/biofuel cells.
期刊最新文献
Cover Picture: (Electroanalysis 11/2024) RETRACTION: Copper Oxide Nanoparticles with Graphitic Carbon Nitride for Ultrasensitive Photoelectrochemical Aptasensor of Bisphenol A Cover Picture: (Electroanalysis 10/2024) Perspectives on Photocatalytic Paper‐based Batteries Fueled by Alcohol Cover Picture: (Electroanalysis 9/2024)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1