{"title":"MSU 高加索山天文台的新型红外摄像机:设计、主要参数和首次点亮","authors":"S. G. Zheltoukhov, A. M. Tatarnikov, A. A. Belyakova, E. A. Koksharova","doi":"10.3103/s0027134924700097","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Abstract</h3><p>This paper presents a prototype of an infrared photometer, created at the Sternberg Astronomical Institute, Lomonosov Moscow State University (SAI MSU), based on the commercial infrared module Gavin-615A. The operating spectral range of the photometer is 3–5 <span>\\(\\mu\\)</span>m. Investigations of the photometer’s detector have shown that its parameters coincide with those stated by the manufacturer. The nonlinearity of the detector does not exceed <span>\\({\\sim}5\\%\\)</span> across the entire signal range, and coefficients for correction functions were determined. Additionally, we determined the readout noise <span>\\(\\textrm{RN}=1200\\pm 210e^{-}\\)</span>, the conversion coefficient <span>\\(\\textrm{GAIN}=520\\pm 9e^{-}/\\)</span>ADU, the signal magnitude of the bias frame <span>\\(\\textrm{BIAS}=960.5\\pm 2.2\\)</span> ADU, and the dark current <span>\\({\\approx}(9.3\\pm 1.1)\\times 10^{6}e^{-}\\)</span>/s, which is the sum of the detector’s dark current and the radiation from the entrance window of the detector module. The value of dark current was measured at a window temperature of <span>\\(6^{\\circ}\\)</span>C. Observations commenced with the photometer at the 2.5-m telescope of the Caucasian Mountain Observatory of MSU, with the first results presented in this paper. The unvignetted field of view was <span>\\(30^{\\prime\\prime}\\)</span>. In the <span>\\(M\\)</span> band under good atmospheric conditions, an image quality close to the diffraction limit was achieved. Images of a star with brightness <span>\\(L=7.96\\)</span> and <span>\\(M=6.78\\)</span> were obtained over the 20-s exposure time and a <span>\\(\\textrm{SNR}\\sim 10\\)</span> ratio. It is shown that at high image quality with <span>\\(\\textrm{SNR}=3\\)</span> and exposure of 20 s it is possible to observe stars up to <span>\\(L\\sim\\)</span> 9<span>\\({}^{m}\\)</span> and <span>\\(M\\sim 8^{m}\\)</span>. The main module of the photometer was also used in measurements of the sky background brightness.</p>","PeriodicalId":711,"journal":{"name":"Moscow University Physics Bulletin","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New Infrared Camera of the Caucasian Mountain Observatory of the SAI MSU: Design, Main Parameters, and First Light\",\"authors\":\"S. G. Zheltoukhov, A. M. Tatarnikov, A. A. Belyakova, E. A. Koksharova\",\"doi\":\"10.3103/s0027134924700097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Abstract</h3><p>This paper presents a prototype of an infrared photometer, created at the Sternberg Astronomical Institute, Lomonosov Moscow State University (SAI MSU), based on the commercial infrared module Gavin-615A. The operating spectral range of the photometer is 3–5 <span>\\\\(\\\\mu\\\\)</span>m. Investigations of the photometer’s detector have shown that its parameters coincide with those stated by the manufacturer. The nonlinearity of the detector does not exceed <span>\\\\({\\\\sim}5\\\\%\\\\)</span> across the entire signal range, and coefficients for correction functions were determined. Additionally, we determined the readout noise <span>\\\\(\\\\textrm{RN}=1200\\\\pm 210e^{-}\\\\)</span>, the conversion coefficient <span>\\\\(\\\\textrm{GAIN}=520\\\\pm 9e^{-}/\\\\)</span>ADU, the signal magnitude of the bias frame <span>\\\\(\\\\textrm{BIAS}=960.5\\\\pm 2.2\\\\)</span> ADU, and the dark current <span>\\\\({\\\\approx}(9.3\\\\pm 1.1)\\\\times 10^{6}e^{-}\\\\)</span>/s, which is the sum of the detector’s dark current and the radiation from the entrance window of the detector module. The value of dark current was measured at a window temperature of <span>\\\\(6^{\\\\circ}\\\\)</span>C. Observations commenced with the photometer at the 2.5-m telescope of the Caucasian Mountain Observatory of MSU, with the first results presented in this paper. The unvignetted field of view was <span>\\\\(30^{\\\\prime\\\\prime}\\\\)</span>. In the <span>\\\\(M\\\\)</span> band under good atmospheric conditions, an image quality close to the diffraction limit was achieved. Images of a star with brightness <span>\\\\(L=7.96\\\\)</span> and <span>\\\\(M=6.78\\\\)</span> were obtained over the 20-s exposure time and a <span>\\\\(\\\\textrm{SNR}\\\\sim 10\\\\)</span> ratio. It is shown that at high image quality with <span>\\\\(\\\\textrm{SNR}=3\\\\)</span> and exposure of 20 s it is possible to observe stars up to <span>\\\\(L\\\\sim\\\\)</span> 9<span>\\\\({}^{m}\\\\)</span> and <span>\\\\(M\\\\sim 8^{m}\\\\)</span>. The main module of the photometer was also used in measurements of the sky background brightness.</p>\",\"PeriodicalId\":711,\"journal\":{\"name\":\"Moscow University Physics Bulletin\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Moscow University Physics Bulletin\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.3103/s0027134924700097\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Moscow University Physics Bulletin","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.3103/s0027134924700097","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

摘要 本文介绍了莫斯科国立罗蒙诺索夫大学斯特恩贝格天文研究所(SAI MSU)在商用红外模块 Gavin-615A 的基础上研制的红外光度计原型。光度计的工作光谱范围为 3-5 \(\mu\)m。对光度计探测器的研究表明,其参数与制造商提供的参数一致。在整个信号范围内,探测器的非线性不超过 \({\sim}5\%\),校正函数的系数也已确定。此外,我们还确定了读出噪声(textrm{RN}=1200/pm 210e^{-})、转换系数(textrm{GAIN}=520/pm 9e^{-}/)ADU、偏置帧的信号幅度(textrm{BIAS}=960.暗电流(({\approx}(9.3\pm 1.1)\times 10^{6}e^{-})/s,即探测器暗电流与探测器模块入口窗口辐射之和。暗电流值是在窗口温度为 \(6^{\circ}\)C 时测量的。在莫斯科大学高加索山天文台的 2.5 米望远镜上开始使用光度计进行观测,并在本文中首次公布了观测结果。无遮挡视场为 \(30^{\prime\prime}\)。在良好的大气条件下的(M)波段,图像质量接近衍射极限。在 20 秒的曝光时间内,获得了一颗亮度为 L=7.96、M=6.78 的恒星的图像,图像比为(textrm{SNR}\sim 10)。结果表明,在图像质量高、曝光时间为20秒、曝光量为(textrm{SNR}=3)的情况下,可以观测到高达(L)9({}^{m})和(M)8^{m}的恒星。光度计的主模块还用于测量天空背景亮度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New Infrared Camera of the Caucasian Mountain Observatory of the SAI MSU: Design, Main Parameters, and First Light

Abstract

This paper presents a prototype of an infrared photometer, created at the Sternberg Astronomical Institute, Lomonosov Moscow State University (SAI MSU), based on the commercial infrared module Gavin-615A. The operating spectral range of the photometer is 3–5 \(\mu\)m. Investigations of the photometer’s detector have shown that its parameters coincide with those stated by the manufacturer. The nonlinearity of the detector does not exceed \({\sim}5\%\) across the entire signal range, and coefficients for correction functions were determined. Additionally, we determined the readout noise \(\textrm{RN}=1200\pm 210e^{-}\), the conversion coefficient \(\textrm{GAIN}=520\pm 9e^{-}/\)ADU, the signal magnitude of the bias frame \(\textrm{BIAS}=960.5\pm 2.2\) ADU, and the dark current \({\approx}(9.3\pm 1.1)\times 10^{6}e^{-}\)/s, which is the sum of the detector’s dark current and the radiation from the entrance window of the detector module. The value of dark current was measured at a window temperature of \(6^{\circ}\)C. Observations commenced with the photometer at the 2.5-m telescope of the Caucasian Mountain Observatory of MSU, with the first results presented in this paper. The unvignetted field of view was \(30^{\prime\prime}\). In the \(M\) band under good atmospheric conditions, an image quality close to the diffraction limit was achieved. Images of a star with brightness \(L=7.96\) and \(M=6.78\) were obtained over the 20-s exposure time and a \(\textrm{SNR}\sim 10\) ratio. It is shown that at high image quality with \(\textrm{SNR}=3\) and exposure of 20 s it is possible to observe stars up to \(L\sim\) 9\({}^{m}\) and \(M\sim 8^{m}\). The main module of the photometer was also used in measurements of the sky background brightness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Moscow University Physics Bulletin
Moscow University Physics Bulletin PHYSICS, MULTIDISCIPLINARY-
CiteScore
0.70
自引率
0.00%
发文量
129
审稿时长
6-12 weeks
期刊介绍: Moscow University Physics Bulletin publishes original papers (reviews, articles, and brief communications) in the following fields of experimental and theoretical physics: theoretical and mathematical physics; physics of nuclei and elementary particles; radiophysics, electronics, acoustics; optics and spectroscopy; laser physics; condensed matter physics; chemical physics, physical kinetics, and plasma physics; biophysics and medical physics; astronomy, astrophysics, and cosmology; physics of the Earth’s, atmosphere, and hydrosphere.
期刊最新文献
Assessment of Dynamic Disorder in DNA Oligonucleotides Using Low-Frequency Raman Spectroscopy Field Electron Emission from Point Diamond Cathodes under Continuous Laser Irradiation Calculation of the Effective Mass of Electrons and Holes of the TlGaTe $${}_{\mathbf{2}}$$ Compound A Monte Carlo Simulation Study of the Optimal Source Offset for Scatter Fraction Estimation in PET and the Influence of the Scanner and Object Characteristics Simulation of the April 27, 2012 Flare Emission in the Spectral Lines of Hydrogen, Helium, and Calcium
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1