Yuya Nitta, Y. Ueda, S. Ohira, M. Isono, Asako Hirose, S. Inui, S. Murata, Hikari Minami, Tomohiro Sagawa, Yukari Nagayasu, M. Miyazaki, K. Konishi
{"title":"带有陀螺仪传感器的便携式呼吸训练系统的可行性。","authors":"Yuya Nitta, Y. Ueda, S. Ohira, M. Isono, Asako Hirose, S. Inui, S. Murata, Hikari Minami, Tomohiro Sagawa, Yukari Nagayasu, M. Miyazaki, K. Konishi","doi":"10.1093/bjr/tqae085","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\nA portable respiratory training system with a gyroscope sensor (GRTS) was developed and the feasibility of respiratory training was evaluated.\n\n\nMETHODS\nSimulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing liver stereotactic body radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively.\n\n\nRESULTS\nThe absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.1%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 95.5% for free breathing and 80.7% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm, and 91.0% (6.9) and 89.1% (11.6), respectively.\n\n\nCONCLUSIONS\nRespiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold liver stereotactic body radiation therapy.\n\n\nADVANCES IN KNOWLEDGE\nA respiratory training system with a gyroscope sensor is inexpensive and portabl, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.","PeriodicalId":516851,"journal":{"name":"The British Journal of Radiology","volume":"84 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility of a portable respiratory training system with a gyroscope sensor.\",\"authors\":\"Yuya Nitta, Y. Ueda, S. Ohira, M. Isono, Asako Hirose, S. Inui, S. Murata, Hikari Minami, Tomohiro Sagawa, Yukari Nagayasu, M. Miyazaki, K. Konishi\",\"doi\":\"10.1093/bjr/tqae085\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVES\\nA portable respiratory training system with a gyroscope sensor (GRTS) was developed and the feasibility of respiratory training was evaluated.\\n\\n\\nMETHODS\\nSimulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing liver stereotactic body radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively.\\n\\n\\nRESULTS\\nThe absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.1%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 95.5% for free breathing and 80.7% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm, and 91.0% (6.9) and 89.1% (11.6), respectively.\\n\\n\\nCONCLUSIONS\\nRespiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold liver stereotactic body radiation therapy.\\n\\n\\nADVANCES IN KNOWLEDGE\\nA respiratory training system with a gyroscope sensor is inexpensive and portabl, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.\",\"PeriodicalId\":516851,\"journal\":{\"name\":\"The British Journal of Radiology\",\"volume\":\"84 12\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The British Journal of Radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/bjr/tqae085\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The British Journal of Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/bjr/tqae085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Feasibility of a portable respiratory training system with a gyroscope sensor.
OBJECTIVES
A portable respiratory training system with a gyroscope sensor (GRTS) was developed and the feasibility of respiratory training was evaluated.
METHODS
Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing liver stereotactic body radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively.
RESULTS
The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.1%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 95.5% for free breathing and 80.7% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm, and 91.0% (6.9) and 89.1% (11.6), respectively.
CONCLUSIONS
Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold liver stereotactic body radiation therapy.
ADVANCES IN KNOWLEDGE
A respiratory training system with a gyroscope sensor is inexpensive and portabl, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.