使用不同翻转角演化(SPACE)迭代去噪的对比后加速三维 T1 取样完善与应用优化对比治疗颅内增强病变的临床可行性:一项回顾性研究。

IF 18 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-04-16 DOI:10.1177/02841851241245104
Su Young Yun, Young Jin Heo
{"title":"使用不同翻转角演化(SPACE)迭代去噪的对比后加速三维 T1 取样完善与应用优化对比治疗颅内增强病变的临床可行性:一项回顾性研究。","authors":"Su Young Yun, Young Jin Heo","doi":"10.1177/02841851241245104","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nPost-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time.\n\n\nPURPOSE\nTo evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients.\n\n\nMATERIAL AND METHODS\nFor evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratiolesion/parenchyma, and number of enhancing lesions for standard and accelerated T1-SPACE without ID.\n\n\nRESULTS\nAlthough there was a significant difference in the overall image quality and mean contrast-to-noise ratiolesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size.\n\n\nCONCLUSION\nAlthough accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"9 13","pages":"2841851241245104"},"PeriodicalIF":18.0000,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical feasibility of post-contrast accelerated 3D T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) with iterative denoising for intracranial enhancing lesions: a retrospective study.\",\"authors\":\"Su Young Yun, Young Jin Heo\",\"doi\":\"10.1177/02841851241245104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND\\nPost-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time.\\n\\n\\nPURPOSE\\nTo evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients.\\n\\n\\nMATERIAL AND METHODS\\nFor evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratiolesion/parenchyma, and number of enhancing lesions for standard and accelerated T1-SPACE without ID.\\n\\n\\nRESULTS\\nAlthough there was a significant difference in the overall image quality and mean contrast-to-noise ratiolesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size.\\n\\n\\nCONCLUSION\\nAlthough accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":\"9 13\",\"pages\":\"2841851241245104\"},\"PeriodicalIF\":18.0000,\"publicationDate\":\"2024-04-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/02841851241245104\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851241245104","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

背景使用不同翻转角演化(SPACE)的后对比 T1 取样完善与应用优化对比(Post-contrast T1-Sampling Perfection with Application-optimized Contrasts)是评估脑转移瘤的首选三维 T1 自旋回波序列,而无需考虑扫描时间的延长。材料和方法为了评估颅内病变,108 位患者在同一次成像过程中接受了标准和加速 T1-SPACE 扫描。结果虽然标准和加速 T1-SPACE 的整体图像质量和平均对比度-噪声鼠小血管/肾小管在无 ID 和有 ID 和无 ID 的加速 SPACE 之间有显著差异,但有 ID 的标准和加速 T1-SPACE 之间无显著差异。加速 T1-SPACE 显示的伪影多于标准 T1-SPACE;但是,带 ID 的加速 T1-SPACE 显示的伪影明显少于不带 ID 的加速 T1-SPACE。不带 ID 的加速 T1-SPACE 显示的增强病灶数量明显少于带 ID 的标准 T1-SPACE 和加速 T1-SPACE;但是,无论病灶大小如何,标准 T1-SPACE 和带 ID 的加速 T1-SPACE 之间没有明显差异。将 ID 应用于加速 T1-SPACE 可获得与标准 T1-SPACE 相当的整体图像质量,并能检测到脑实质中的增强病灶。带有 ID 的加速 T1-SPACE 有可能取代标准 T1-SPACE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical feasibility of post-contrast accelerated 3D T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) with iterative denoising for intracranial enhancing lesions: a retrospective study.
BACKGROUND Post-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time. PURPOSE To evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients. MATERIAL AND METHODS For evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratiolesion/parenchyma, and number of enhancing lesions for standard and accelerated T1-SPACE without ID. RESULTS Although there was a significant difference in the overall image quality and mean contrast-to-noise ratiolesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size. CONCLUSION Although accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Design Principles for Negative Thermal Expansion in Two-Dimensional Materials. Main Group Redox Catalysis: New Frontiers with Germanium and Tin. Taming Irreversibility in sp2-Carbon-Conjugated COFs from Polycrystalline Powders to Single Crystals and Thin Films. Calix[4]resorcinarene-Based Porous Organic Cages: Synthesis and Applications. Electroactive Imidazolium Ionic Liquids in Organic Synthesis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1