{"title":"为泰国核医学诊断中的管理活动制定国家诊断参考水平。","authors":"Dutsadee Suttho","doi":"10.2967/jnmt.123.266836","DOIUrl":null,"url":null,"abstract":"The diagnostic reference level (DRL) is a patient-exposure optimization tool used to evaluate radiation doses in medical imaging and provide guidance for protection from them. In Thailand, nuclear medicine DRLs have not been established yet. Therefore, this study surveyed dose levels in routine nuclear medicine procedures to provide national DRLs (NDRLs). Methods: NDRLs in Thailand were established by investigating the administered activity of radiopharmaceuticals in nuclear medicine examination studies. The NDRLs were determined on the basis of the 75th percentile (third quartile) of administered activity distribution as recommended by the International Commission on Radiological Protection. As part of a nationwide survey, datasets for the period between June 1, 2018, and August 31, 2019, were collected from 21 Thailand hospitals with nuclear medicine equipment. All hospitals were asked to report the nuclear medicine imaging devices in use, the standard protocol parameters for selected examinations, the injected activities, and the ages and weights of patients. All data were calculated to determine Thailand NDRLs, which were compared with international NDRLs. Results: The data reported by the 21 hospitals consisted of 4,641 examinations with SPECT or SPECT/CT for general nuclear medicine and 409 examinations with PET. The most widely performed examinations for SPECT were bone, thyroid, oncology, and cardiovascular imaging. The NDRLs for SPECT or SPECT/CT agreed well with published NDRLs for Europe, the United States, Japan, Korea, Kuwait, and Australia. In contrast, the NDRLs for 18F-FDG PET in oncology studies were higher than for Japan, Korea, Kuwait, and Australia but lower than for the United States, the United Kingdom, and the European Union. Conclusion: This study presents NDRL results for adults in Thailand as a way to optimize radiation protection in nuclear medicine imaging. Moreover, the reported injected activity levels were comparable to those of other countries.","PeriodicalId":16548,"journal":{"name":"Journal of nuclear medicine technology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Establishment of National Diagnostic Reference Levels for Administered Activity in Diagnostic Nuclear Medicine in Thailand.\",\"authors\":\"Dutsadee Suttho\",\"doi\":\"10.2967/jnmt.123.266836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The diagnostic reference level (DRL) is a patient-exposure optimization tool used to evaluate radiation doses in medical imaging and provide guidance for protection from them. In Thailand, nuclear medicine DRLs have not been established yet. Therefore, this study surveyed dose levels in routine nuclear medicine procedures to provide national DRLs (NDRLs). Methods: NDRLs in Thailand were established by investigating the administered activity of radiopharmaceuticals in nuclear medicine examination studies. The NDRLs were determined on the basis of the 75th percentile (third quartile) of administered activity distribution as recommended by the International Commission on Radiological Protection. As part of a nationwide survey, datasets for the period between June 1, 2018, and August 31, 2019, were collected from 21 Thailand hospitals with nuclear medicine equipment. All hospitals were asked to report the nuclear medicine imaging devices in use, the standard protocol parameters for selected examinations, the injected activities, and the ages and weights of patients. All data were calculated to determine Thailand NDRLs, which were compared with international NDRLs. Results: The data reported by the 21 hospitals consisted of 4,641 examinations with SPECT or SPECT/CT for general nuclear medicine and 409 examinations with PET. The most widely performed examinations for SPECT were bone, thyroid, oncology, and cardiovascular imaging. The NDRLs for SPECT or SPECT/CT agreed well with published NDRLs for Europe, the United States, Japan, Korea, Kuwait, and Australia. In contrast, the NDRLs for 18F-FDG PET in oncology studies were higher than for Japan, Korea, Kuwait, and Australia but lower than for the United States, the United Kingdom, and the European Union. Conclusion: This study presents NDRL results for adults in Thailand as a way to optimize radiation protection in nuclear medicine imaging. Moreover, the reported injected activity levels were comparable to those of other countries.\",\"PeriodicalId\":16548,\"journal\":{\"name\":\"Journal of nuclear medicine technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-04-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of nuclear medicine technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2967/jnmt.123.266836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnmt.123.266836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

诊断参考水平(DRL)是一种患者辐照优化工具,用于评估医学成像中的辐射剂量,并提供防护指导。泰国尚未制定核医学诊断参考水平。因此,本研究调查了常规核医学程序中的剂量水平,以提供国家诊断参考水平(NDRLs)。方法:通过调查核医学检查研究中放射性药物的给药活性,确定泰国的国家 DRL。按照国际放射防护委员会的建议,NDRL 是根据放射性活度分布的第 75 个百分位数(第三四分位数)确定的。作为全国性调查的一部分,从泰国 21 家拥有核医学设备的医院收集了 2018 年 6 月 1 日至 2019 年 8 月 31 日期间的数据集。要求所有医院报告使用的核医学成像设备、选定检查的标准协议参数、注射活动以及患者的年龄和体重。所有数据都经过计算,以确定泰国的 NDRL,并与国际 NDRL 进行比较。结果:21 家医院报告的数据包括 4,641 次普通核医学 SPECT 或 SPECT/CT 检查和 409 次 PET 检查。进行最多的 SPECT 检查是骨骼、甲状腺、肿瘤和心血管成像。SPECT 或 SPECT/CT 的 NDRL 与欧洲、美国、日本、韩国、科威特和澳大利亚公布的 NDRL 非常一致。相比之下,肿瘤研究中 18F-FDG PET 的 NDRL 高于日本、韩国、科威特和澳大利亚,但低于美国、英国和欧盟。结论:本研究介绍了泰国成人的 NDRL 结果,以此优化核医学成像中的辐射防护。此外,报告的注射活度水平与其他国家相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Establishment of National Diagnostic Reference Levels for Administered Activity in Diagnostic Nuclear Medicine in Thailand.
The diagnostic reference level (DRL) is a patient-exposure optimization tool used to evaluate radiation doses in medical imaging and provide guidance for protection from them. In Thailand, nuclear medicine DRLs have not been established yet. Therefore, this study surveyed dose levels in routine nuclear medicine procedures to provide national DRLs (NDRLs). Methods: NDRLs in Thailand were established by investigating the administered activity of radiopharmaceuticals in nuclear medicine examination studies. The NDRLs were determined on the basis of the 75th percentile (third quartile) of administered activity distribution as recommended by the International Commission on Radiological Protection. As part of a nationwide survey, datasets for the period between June 1, 2018, and August 31, 2019, were collected from 21 Thailand hospitals with nuclear medicine equipment. All hospitals were asked to report the nuclear medicine imaging devices in use, the standard protocol parameters for selected examinations, the injected activities, and the ages and weights of patients. All data were calculated to determine Thailand NDRLs, which were compared with international NDRLs. Results: The data reported by the 21 hospitals consisted of 4,641 examinations with SPECT or SPECT/CT for general nuclear medicine and 409 examinations with PET. The most widely performed examinations for SPECT were bone, thyroid, oncology, and cardiovascular imaging. The NDRLs for SPECT or SPECT/CT agreed well with published NDRLs for Europe, the United States, Japan, Korea, Kuwait, and Australia. In contrast, the NDRLs for 18F-FDG PET in oncology studies were higher than for Japan, Korea, Kuwait, and Australia but lower than for the United States, the United Kingdom, and the European Union. Conclusion: This study presents NDRL results for adults in Thailand as a way to optimize radiation protection in nuclear medicine imaging. Moreover, the reported injected activity levels were comparable to those of other countries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of nuclear medicine technology
Journal of nuclear medicine technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.90
自引率
15.40%
发文量
57
期刊最新文献
A Rare Case of Orbital Metastasis from Invasive Lobular Carcinoma: Challenges of 18F-FDG PET/CT and the Search for Consensus on Imaging. Brain Imaging: Amyloid-β PET. Gender and Ethnicity Bias of Text-to-Image Generative Artificial Intelligence in Medical Imaging, Part 1: Preliminary Evaluation. Gender and Ethnicity Bias of Text-to-Image Generative Artificial Intelligence in Medical Imaging, Part 2: Analysis of DALL-E 3. Comment Regarding "Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1