Susana Clemente Bautista, I. Jiménez Lozano, Laura Castellote Belles, C. Parramón-Teixidó, Carme Garcia Esquerda, A. Puertas Sanjuan, Carla Daina Noves, Vanessa Segura Encinas, Maria Josep Cabañas Poy
{"title":"儿科重症监护室静脉注射硫酸镁与磷酸二氢钾或磷酸二氢钠之间的物理兼容性","authors":"Susana Clemente Bautista, I. Jiménez Lozano, Laura Castellote Belles, C. Parramón-Teixidó, Carme Garcia Esquerda, A. Puertas Sanjuan, Carla Daina Noves, Vanessa Segura Encinas, Maria Josep Cabañas Poy","doi":"10.1177/00185787241247133","DOIUrl":null,"url":null,"abstract":"Objective:To evaluate the physical compatibility between intravenous magnesium sulfate and potassium and sodium phosphate, a common electrolyte intravenous supplementation in pediatric intensive care units. Study design: Magnesium sulfate was mixed separately with potassium phosphate and sodium phosphate at ratios of 1:1, 1:4, and 4:1. Binary mixtures were prepared, in triplicate and under sterile conditions, by permuting the order of addition. The undiluted pure drugs were used as controls for possible sequence effects. Visual changes, turbidity, and pH were assessed immediately after mixing (baseline) and at 4 and 24 hours. Two observers performed visual changes by naked-eye visual inspection in order to search visible haze, particulate matter, gas formation, or color change. Turbidity was measured by nephelometry and incompatibility was defined as an increase of ≥0.5 nephelometric turbidity units (NTU) from baseline. pH was measured using a portable pH meter and incompatibility was defined as a variation of >1 pH unit during the observation period. Results: None of the admixtures exhibited visual changes or significant variations in turbidity (increases of ≥0.5 in nephelometric turbidity units) or pH (changes of >1 unit) during the observation period and neither compared with baseline. Conclusion: In this study, no visual changes were observed, and turbidity and pH evaluated by instrumental methods remained within acceptable limits and showed no significant variations from baseline, therefore no physical incompatibility between magnesium sulfate and potassium or sodium phosphate was found.","PeriodicalId":13002,"journal":{"name":"Hospital Pharmacy","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Physical Compatibility Between Intravenous Magnesium Sulfate and Potassium or Sodium Phosphate in a Pediatric Intensive Care Unit\",\"authors\":\"Susana Clemente Bautista, I. Jiménez Lozano, Laura Castellote Belles, C. Parramón-Teixidó, Carme Garcia Esquerda, A. Puertas Sanjuan, Carla Daina Noves, Vanessa Segura Encinas, Maria Josep Cabañas Poy\",\"doi\":\"10.1177/00185787241247133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective:To evaluate the physical compatibility between intravenous magnesium sulfate and potassium and sodium phosphate, a common electrolyte intravenous supplementation in pediatric intensive care units. Study design: Magnesium sulfate was mixed separately with potassium phosphate and sodium phosphate at ratios of 1:1, 1:4, and 4:1. Binary mixtures were prepared, in triplicate and under sterile conditions, by permuting the order of addition. The undiluted pure drugs were used as controls for possible sequence effects. Visual changes, turbidity, and pH were assessed immediately after mixing (baseline) and at 4 and 24 hours. Two observers performed visual changes by naked-eye visual inspection in order to search visible haze, particulate matter, gas formation, or color change. Turbidity was measured by nephelometry and incompatibility was defined as an increase of ≥0.5 nephelometric turbidity units (NTU) from baseline. pH was measured using a portable pH meter and incompatibility was defined as a variation of >1 pH unit during the observation period. Results: None of the admixtures exhibited visual changes or significant variations in turbidity (increases of ≥0.5 in nephelometric turbidity units) or pH (changes of >1 unit) during the observation period and neither compared with baseline. Conclusion: In this study, no visual changes were observed, and turbidity and pH evaluated by instrumental methods remained within acceptable limits and showed no significant variations from baseline, therefore no physical incompatibility between magnesium sulfate and potassium or sodium phosphate was found.\",\"PeriodicalId\":13002,\"journal\":{\"name\":\"Hospital Pharmacy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hospital Pharmacy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/00185787241247133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hospital Pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/00185787241247133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
Physical Compatibility Between Intravenous Magnesium Sulfate and Potassium or Sodium Phosphate in a Pediatric Intensive Care Unit
Objective:To evaluate the physical compatibility between intravenous magnesium sulfate and potassium and sodium phosphate, a common electrolyte intravenous supplementation in pediatric intensive care units. Study design: Magnesium sulfate was mixed separately with potassium phosphate and sodium phosphate at ratios of 1:1, 1:4, and 4:1. Binary mixtures were prepared, in triplicate and under sterile conditions, by permuting the order of addition. The undiluted pure drugs were used as controls for possible sequence effects. Visual changes, turbidity, and pH were assessed immediately after mixing (baseline) and at 4 and 24 hours. Two observers performed visual changes by naked-eye visual inspection in order to search visible haze, particulate matter, gas formation, or color change. Turbidity was measured by nephelometry and incompatibility was defined as an increase of ≥0.5 nephelometric turbidity units (NTU) from baseline. pH was measured using a portable pH meter and incompatibility was defined as a variation of >1 pH unit during the observation period. Results: None of the admixtures exhibited visual changes or significant variations in turbidity (increases of ≥0.5 in nephelometric turbidity units) or pH (changes of >1 unit) during the observation period and neither compared with baseline. Conclusion: In this study, no visual changes were observed, and turbidity and pH evaluated by instrumental methods remained within acceptable limits and showed no significant variations from baseline, therefore no physical incompatibility between magnesium sulfate and potassium or sodium phosphate was found.
期刊介绍:
Hospital Pharmacy is a monthly peer-reviewed journal that is read by pharmacists and other providers practicing in the inpatient and outpatient setting within hospitals, long-term care facilities, home care, and other health-system settings The Hospital Pharmacy Assistant Editor, Michael R. Cohen, RPh, MS, DSc, FASHP, is author of a Medication Error Report Analysis and founder of The Institute for Safe Medication Practices (ISMP), a nonprofit organization that provides education about adverse drug events and their prevention.