刚性地基上立式水箱的有限元模型

O. Kucherenko
{"title":"刚性地基上立式水箱的有限元模型","authors":"O. Kucherenko","doi":"10.15407/itm2024.01.058","DOIUrl":null,"url":null,"abstract":"This study addresses the problem of finite element modeling of a 20,000 m3 vertical steel tank subjected to static loads. The structure includes a cylindrical wall of total height 17,880 mm and diameter 39,900 mm. The shell thicknesses of the cylindrical wall are determined according to strength and buckling design standards. The geometric model is axisymmetric. The analysis involves the calculation of the stress and strain fields of the cylindrical wall and the contact zone between the flat bottom and the rigid foundation under various combinations of external loads, namely, excessive and hydrostatic pressures. The ANSYS Mechanical software is used for finite element analysis. Three-dimensional SOLID186 and SHELL281 elements are used for axisymmetric modeling of the shell structure in a three-dimensional formulation. To simulate the contact zone, CONTA174 and TARGE170 finite elements are used to model the moving contact surface of the bottom and the fixed surface of the rigid foundation, respectively. The model is verified by comparing the radial displacements calculated numerically and analytically. The discrepancy does not exceed 4%, thus evidencing the adequacy of the finite element model. The contact zone is analyzed for non-standard service conditions, such an excessive internal pressure in the tank (2.5 and 3 kPa compared to 2 kPa under normal conditions). The unilaterally constrained \"bottom–foundation\" contact zone model allows the bottom to detach from the foundation, thus leading to contact opening. A full detachment occurs under a certain combination of the excessive and the hydrostatic pressure. For certain liquid levels in the tank, the gap decreases, which may be due to a reduced effect of the excessive pressure. This is accompanied by the development of internal detachment caused by the increasing moment from the hydrostatic pressure. The internal detachment increases the bending moment at the wall–bottom junction, which, under certain conditions, may cause plastic deformations followed by the development of an emergency state.","PeriodicalId":287730,"journal":{"name":"Technical mechanics","volume":"27 11","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Finite-element model of a vertical tank on a rigid foundation\",\"authors\":\"O. Kucherenko\",\"doi\":\"10.15407/itm2024.01.058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study addresses the problem of finite element modeling of a 20,000 m3 vertical steel tank subjected to static loads. The structure includes a cylindrical wall of total height 17,880 mm and diameter 39,900 mm. The shell thicknesses of the cylindrical wall are determined according to strength and buckling design standards. The geometric model is axisymmetric. The analysis involves the calculation of the stress and strain fields of the cylindrical wall and the contact zone between the flat bottom and the rigid foundation under various combinations of external loads, namely, excessive and hydrostatic pressures. The ANSYS Mechanical software is used for finite element analysis. Three-dimensional SOLID186 and SHELL281 elements are used for axisymmetric modeling of the shell structure in a three-dimensional formulation. To simulate the contact zone, CONTA174 and TARGE170 finite elements are used to model the moving contact surface of the bottom and the fixed surface of the rigid foundation, respectively. The model is verified by comparing the radial displacements calculated numerically and analytically. The discrepancy does not exceed 4%, thus evidencing the adequacy of the finite element model. The contact zone is analyzed for non-standard service conditions, such an excessive internal pressure in the tank (2.5 and 3 kPa compared to 2 kPa under normal conditions). The unilaterally constrained \\\"bottom–foundation\\\" contact zone model allows the bottom to detach from the foundation, thus leading to contact opening. A full detachment occurs under a certain combination of the excessive and the hydrostatic pressure. For certain liquid levels in the tank, the gap decreases, which may be due to a reduced effect of the excessive pressure. This is accompanied by the development of internal detachment caused by the increasing moment from the hydrostatic pressure. The internal detachment increases the bending moment at the wall–bottom junction, which, under certain conditions, may cause plastic deformations followed by the development of an emergency state.\",\"PeriodicalId\":287730,\"journal\":{\"name\":\"Technical mechanics\",\"volume\":\"27 11\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technical mechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15407/itm2024.01.058\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical mechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15407/itm2024.01.058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究解决了一个 20,000 立方米立式钢罐在静载荷作用下的有限元建模问题。该结构包括总高度为 17,880 毫米、直径为 39,900 毫米的圆柱形壁。圆柱壁的壳体厚度根据强度和屈曲设计标准确定。几何模型为轴对称模型。分析包括计算圆柱壁的应力场和应变场,以及平底与刚性地基之间的接触区在各种外部载荷组合(即过大压力和静水压力)下的应力场和应变场。ANSYS Mechanical 软件用于有限元分析。三维 SOLID186 和 SHELL281 元素用于以三维形式对壳体结构进行轴对称建模。为了模拟接触区,使用 CONTA174 和 TARGE170 有限元分别模拟底部的移动接触面和刚性基础的固定面。通过比较数值计算和分析计算的径向位移,对模型进行了验证。差异不超过 4%,从而证明了有限元模型的充分性。对接触区进行了非标准工况分析,例如罐内压力过高(2.5 和 3 kPa,而正常情况下为 2 kPa)。单侧约束的 "底部-地基 "接触区模型允许底部从地基上脱离,从而导致接触开口。在过度压力和静水压力的特定组合下,会发生完全脱离。当罐内液位达到一定程度时,间隙会减小,这可能是由于过大压力的作用减弱所致。与此同时,静水压力产生的力矩不断增大,导致内部脱落。内部脱落增加了罐壁和罐底交界处的弯矩,在某些情况下,可能会导致塑性变形,继而形成紧急状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Finite-element model of a vertical tank on a rigid foundation
This study addresses the problem of finite element modeling of a 20,000 m3 vertical steel tank subjected to static loads. The structure includes a cylindrical wall of total height 17,880 mm and diameter 39,900 mm. The shell thicknesses of the cylindrical wall are determined according to strength and buckling design standards. The geometric model is axisymmetric. The analysis involves the calculation of the stress and strain fields of the cylindrical wall and the contact zone between the flat bottom and the rigid foundation under various combinations of external loads, namely, excessive and hydrostatic pressures. The ANSYS Mechanical software is used for finite element analysis. Three-dimensional SOLID186 and SHELL281 elements are used for axisymmetric modeling of the shell structure in a three-dimensional formulation. To simulate the contact zone, CONTA174 and TARGE170 finite elements are used to model the moving contact surface of the bottom and the fixed surface of the rigid foundation, respectively. The model is verified by comparing the radial displacements calculated numerically and analytically. The discrepancy does not exceed 4%, thus evidencing the adequacy of the finite element model. The contact zone is analyzed for non-standard service conditions, such an excessive internal pressure in the tank (2.5 and 3 kPa compared to 2 kPa under normal conditions). The unilaterally constrained "bottom–foundation" contact zone model allows the bottom to detach from the foundation, thus leading to contact opening. A full detachment occurs under a certain combination of the excessive and the hydrostatic pressure. For certain liquid levels in the tank, the gap decreases, which may be due to a reduced effect of the excessive pressure. This is accompanied by the development of internal detachment caused by the increasing moment from the hydrostatic pressure. The internal detachment increases the bending moment at the wall–bottom junction, which, under certain conditions, may cause plastic deformations followed by the development of an emergency state.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Determining the coefficients of a hydrodynamic model of cavitating pumps of liquid-propellant rocket engines from their theoretical transfer matrices Methodological features of in-group evaluation of experts’ competence in determining the efficiency of space-rocket complexes Finite-element model of a vertical tank on a rigid foundation Mathematical model for selecting the auxiliary equipment parameters of aerodynamic deorbit systems Deployment of a space tether in a centrifugal force field with alignment to the local vertical
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1