预防全身麻醉下的意外意识:地区服务评估。

IF 1.2 Q3 SURGERY Journal of perioperative practice Pub Date : 2024-04-08 DOI:10.1177/17504589241228201
Katie L Preston, Alexander Ir Jackson
{"title":"预防全身麻醉下的意外意识:地区服务评估。","authors":"Katie L Preston, Alexander Ir Jackson","doi":"10.1177/17504589241228201","DOIUrl":null,"url":null,"abstract":"The United Kingdom's Fifth National Audit Project investigated the incidence and causes of accidental awareness during general anaesthesia. Subsequently, guidelines produced by the Association of Anaesthetists of Great Britain and Ireland provide key recommendations to minimise awareness. These include using processed electroencephalogram for patients receiving total intravenous anaesthesia while paralysed and using audible low end-tidal anaesthetic concentration alarms. The Southcoast Perioperative Audit and Research Collaboration undertook a five-day regional service evaluation, assessing the measures in place to minimise awareness and conducting a practitioner survey. Eight hospitals participated with 382 theatre attendances were analysed. Processed electroencephalograph monitoring for patients receiving total intravenous anaesthesia with neuromuscular blockade has been widely adopted into regional practice, from 23% of cases in the Fifth National Audit Project, to 85% in this snapshot. During volatile anaesthesia, age-adjusted low end-tidal anaesthetic concentration alarms were used in 34% cases. The range was 0-97% at different hospitals, suggesting heterogeneity in practice. Seventy-six per cent of anaesthetists rarely alter the default anaesthetic machine alarm settings. Therefore, instigating default low end-tidal anaesthetic concentration alarms could improve compliance with guidelines and reduce the risk of awareness for patients.","PeriodicalId":35481,"journal":{"name":"Journal of perioperative practice","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prevention of accidental awareness under general anaesthesia: A regional service evaluation.\",\"authors\":\"Katie L Preston, Alexander Ir Jackson\",\"doi\":\"10.1177/17504589241228201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The United Kingdom's Fifth National Audit Project investigated the incidence and causes of accidental awareness during general anaesthesia. Subsequently, guidelines produced by the Association of Anaesthetists of Great Britain and Ireland provide key recommendations to minimise awareness. These include using processed electroencephalogram for patients receiving total intravenous anaesthesia while paralysed and using audible low end-tidal anaesthetic concentration alarms. The Southcoast Perioperative Audit and Research Collaboration undertook a five-day regional service evaluation, assessing the measures in place to minimise awareness and conducting a practitioner survey. Eight hospitals participated with 382 theatre attendances were analysed. Processed electroencephalograph monitoring for patients receiving total intravenous anaesthesia with neuromuscular blockade has been widely adopted into regional practice, from 23% of cases in the Fifth National Audit Project, to 85% in this snapshot. During volatile anaesthesia, age-adjusted low end-tidal anaesthetic concentration alarms were used in 34% cases. The range was 0-97% at different hospitals, suggesting heterogeneity in practice. Seventy-six per cent of anaesthetists rarely alter the default anaesthetic machine alarm settings. Therefore, instigating default low end-tidal anaesthetic concentration alarms could improve compliance with guidelines and reduce the risk of awareness for patients.\",\"PeriodicalId\":35481,\"journal\":{\"name\":\"Journal of perioperative practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of perioperative practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17504589241228201\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of perioperative practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17504589241228201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

英国第五次全国审计项目调查了全身麻醉期间意外意识的发生率和原因。随后,大不列颠及爱尔兰麻醉师协会(Association of Anaesthetists of Great Britain and Ireland)制定的指南提出了将意识减至最低的主要建议。这些建议包括对在瘫痪状态下接受全静脉麻醉的患者使用经过处理的脑电图,以及使用可听到的低潮气末麻醉浓度警报。南部海岸围术期审计与研究合作组织进行了为期五天的地区服务评估,评估了为最大限度降低意识而采取的措施,并对从业人员进行了调查。八家医院参与了此次评估,共分析了 382 例手术。对接受神经肌肉阻滞全静脉麻醉的患者进行的脑电图监测已被广泛应用于地区性实践中,从第五次全国审计项目中的23%增加到了本次快照中的85%。在挥发性麻醉过程中,有 34% 的病例使用了年龄调整后的低潮气末麻醉浓度警报。不同医院的使用率范围在 0-97% 之间,这表明在实践中存在差异。76%的麻醉师很少更改麻醉机的默认警报设置。因此,设置默认的低潮气末麻醉浓度警报可提高对指南的依从性,并降低患者意识到的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Prevention of accidental awareness under general anaesthesia: A regional service evaluation.
The United Kingdom's Fifth National Audit Project investigated the incidence and causes of accidental awareness during general anaesthesia. Subsequently, guidelines produced by the Association of Anaesthetists of Great Britain and Ireland provide key recommendations to minimise awareness. These include using processed electroencephalogram for patients receiving total intravenous anaesthesia while paralysed and using audible low end-tidal anaesthetic concentration alarms. The Southcoast Perioperative Audit and Research Collaboration undertook a five-day regional service evaluation, assessing the measures in place to minimise awareness and conducting a practitioner survey. Eight hospitals participated with 382 theatre attendances were analysed. Processed electroencephalograph monitoring for patients receiving total intravenous anaesthesia with neuromuscular blockade has been widely adopted into regional practice, from 23% of cases in the Fifth National Audit Project, to 85% in this snapshot. During volatile anaesthesia, age-adjusted low end-tidal anaesthetic concentration alarms were used in 34% cases. The range was 0-97% at different hospitals, suggesting heterogeneity in practice. Seventy-six per cent of anaesthetists rarely alter the default anaesthetic machine alarm settings. Therefore, instigating default low end-tidal anaesthetic concentration alarms could improve compliance with guidelines and reduce the risk of awareness for patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of perioperative practice
Journal of perioperative practice Nursing-Medical and Surgical Nursing
CiteScore
1.60
自引率
0.00%
发文量
59
期刊介绍: The Journal of Perioperative Practice (JPP) is the official journal of the Association for Perioperative Practice (AfPP). It is an international, peer reviewed journal with a multidisciplinary ethos across all aspects of perioperative care. The overall aim of the journal is to improve patient safety through informing and developing practice. It is an informative professional journal which provides current evidence-based practice, clinical, management and educational developments for practitioners working in the perioperative environment. The journal promotes perioperative practice by publishing clinical research-based articles, literature reviews, topical discussions, advice on clinical issues, current news items and product information.
期刊最新文献
Add dexmedetomidine to levobupivacaine for transversus abdominis plane block in elderly patients undergoing inguinal hernia repair: Could it make a difference? A randomised trial. Early versus late removal of the I-Gel in paediatric patients with mild upper respiratory tract symptoms undergoing ambulatory ilioinguinal surgery: A prospective observational study. Prediction of difficult laryngoscopy and/or intubation among morbidly obese patients: Upper lip bite test versus modified Mallampati classification. Comparing preoperative fasting and ultrasound-measured intravascular volume status in elective surgery, enhanced recovery patients versus inpatient, urgent surgery patients and the ability of IVC collapsibility to predict post-induction hypotension. An unexpected life-threatening persistent oxygen desaturation in a child after extubation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1