Mohd Hanif Jamaludin, W. Z. Wan Ismail, Elina Mohd Husini, Nor Ain Mohd Bahror
{"title":"基于光度测量法的道路照明 HSPV 灯具中的 LED 改装灯研究","authors":"Mohd Hanif Jamaludin, W. Z. Wan Ismail, Elina Mohd Husini, Nor Ain Mohd Bahror","doi":"10.47836/pjst.32.3.11","DOIUrl":null,"url":null,"abstract":"Energy reduction is a great challenge in road lighting applications. Replacing high-pressure sodium vapor (HPSV) with light-emitting diodes (LED) is a viable approach to reducing energy consumption. However, a total replacement can incur a significant capital cost. This study aims to investigate the effects on light distribution by replacing HPSV lamps with LED lamps in HPSV luminaires using Light Intensity Distribution (LID) curve measurement and Backlight, Uplight and Glare (BUG) rating evaluation to reduce the adoption costs. While LED lamps have high illumination rates, the structural differences from HPSV lamps can affect the LID curve and original lighting design. Therefore, it is crucial to study photometric dispersion after retrofitting light sources. Both lamps were installed into similar HPSV luminaires to assess photometric performance using goniophotometer measurements. The HPSV lamp outperforms the LED lamp in terms of luminous flux (11.13%) and light intensity (7.69%), whereas the LED lamp outperforms the HPSV lamp in terms of efficacy rating (68.67%) and wattage used (47.61%). The findings indicate that retrofit LED luminaires have an LOR of 46.77% lower than the HPSV luminaires. The light distribution pattern is maintained but reduced to 40 to 50% for the main usable light angles. The reduced performance is caused by the lamp structure, which occupies a large area inside the luminaire housing, obstructing proper light distribution. Although overall energy consumption is reduced, similar illumination levels cannot be maintained. These outcomes can assist authorities and manufacturers with alternative methods of reducing costs while maintaining lighting levels.","PeriodicalId":46234,"journal":{"name":"Pertanika Journal of Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of LED Retrofit Lamps in HSPV Luminaires Based on Photometric Method for Road Lighting\",\"authors\":\"Mohd Hanif Jamaludin, W. Z. Wan Ismail, Elina Mohd Husini, Nor Ain Mohd Bahror\",\"doi\":\"10.47836/pjst.32.3.11\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Energy reduction is a great challenge in road lighting applications. Replacing high-pressure sodium vapor (HPSV) with light-emitting diodes (LED) is a viable approach to reducing energy consumption. However, a total replacement can incur a significant capital cost. This study aims to investigate the effects on light distribution by replacing HPSV lamps with LED lamps in HPSV luminaires using Light Intensity Distribution (LID) curve measurement and Backlight, Uplight and Glare (BUG) rating evaluation to reduce the adoption costs. While LED lamps have high illumination rates, the structural differences from HPSV lamps can affect the LID curve and original lighting design. Therefore, it is crucial to study photometric dispersion after retrofitting light sources. Both lamps were installed into similar HPSV luminaires to assess photometric performance using goniophotometer measurements. The HPSV lamp outperforms the LED lamp in terms of luminous flux (11.13%) and light intensity (7.69%), whereas the LED lamp outperforms the HPSV lamp in terms of efficacy rating (68.67%) and wattage used (47.61%). The findings indicate that retrofit LED luminaires have an LOR of 46.77% lower than the HPSV luminaires. The light distribution pattern is maintained but reduced to 40 to 50% for the main usable light angles. The reduced performance is caused by the lamp structure, which occupies a large area inside the luminaire housing, obstructing proper light distribution. Although overall energy consumption is reduced, similar illumination levels cannot be maintained. These outcomes can assist authorities and manufacturers with alternative methods of reducing costs while maintaining lighting levels.\",\"PeriodicalId\":46234,\"journal\":{\"name\":\"Pertanika Journal of Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pertanika Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47836/pjst.32.3.11\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pertanika Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47836/pjst.32.3.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
在道路照明应用中,降低能耗是一项巨大挑战。用发光二极管(LED)取代高压钠蒸气(HPSV)是降低能耗的可行方法。然而,全面更换会产生巨大的资本成本。本研究旨在通过光强分布(LID)曲线测量和背光、上光和眩光(BUG)等级评估,研究在 HPSV 灯具中用 LED 灯具替换 HPSV 灯具对光分布的影响,以降低采用成本。虽然 LED 灯具有很高的照度,但与 HPSV 灯的结构差异会影响 LID 曲线和原始照明设计。因此,研究光源改造后的光度色散至关重要。将两种灯具安装到类似的 HPSV 灯具中,使用测角光度计测量评估光度性能。HPSV 灯在光通量(11.13%)和光强(7.69%)方面优于 LED 灯,而 LED 灯在效率等级(68.67%)和所用瓦数(47.61%)方面优于 HPSV 灯。研究结果表明,改装 LED 灯具的 LOR 比 HPSV 灯具低 46.77%。光分布模式保持不变,但在主要可用光角方面降低了 40%至 50%。性能降低的原因是灯泡结构在灯具外壳内占据了很大的面积,阻碍了适当的光分布。虽然总体能耗降低了,但却无法保持类似的照明水平。这些结果可以帮助当局和制造商在保持照明水平的同时,找到降低成本的替代方法。
Study of LED Retrofit Lamps in HSPV Luminaires Based on Photometric Method for Road Lighting
Energy reduction is a great challenge in road lighting applications. Replacing high-pressure sodium vapor (HPSV) with light-emitting diodes (LED) is a viable approach to reducing energy consumption. However, a total replacement can incur a significant capital cost. This study aims to investigate the effects on light distribution by replacing HPSV lamps with LED lamps in HPSV luminaires using Light Intensity Distribution (LID) curve measurement and Backlight, Uplight and Glare (BUG) rating evaluation to reduce the adoption costs. While LED lamps have high illumination rates, the structural differences from HPSV lamps can affect the LID curve and original lighting design. Therefore, it is crucial to study photometric dispersion after retrofitting light sources. Both lamps were installed into similar HPSV luminaires to assess photometric performance using goniophotometer measurements. The HPSV lamp outperforms the LED lamp in terms of luminous flux (11.13%) and light intensity (7.69%), whereas the LED lamp outperforms the HPSV lamp in terms of efficacy rating (68.67%) and wattage used (47.61%). The findings indicate that retrofit LED luminaires have an LOR of 46.77% lower than the HPSV luminaires. The light distribution pattern is maintained but reduced to 40 to 50% for the main usable light angles. The reduced performance is caused by the lamp structure, which occupies a large area inside the luminaire housing, obstructing proper light distribution. Although overall energy consumption is reduced, similar illumination levels cannot be maintained. These outcomes can assist authorities and manufacturers with alternative methods of reducing costs while maintaining lighting levels.
期刊介绍:
Pertanika Journal of Science and Technology aims to provide a forum for high quality research related to science and engineering research. Areas relevant to the scope of the journal include: bioinformatics, bioscience, biotechnology and bio-molecular sciences, chemistry, computer science, ecology, engineering, engineering design, environmental control and management, mathematics and statistics, medicine and health sciences, nanotechnology, physics, safety and emergency management, and related fields of study.