腭中微型螺钉植入术:数字规划和手术置入的准确性。

IF 2.7 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE American Journal of Orthodontics and Dentofacial Orthopedics Pub Date : 2024-07-01 DOI:10.1016/j.ajodo.2024.02.014
Adli M.Q. Al-Gazzawi , Vanessa Knode , Bjorn Ludwig , Alaa Othman , Angelo Salamini , Nikolaos Pandis , Padhraig S. Fleming
{"title":"腭中微型螺钉植入术:数字规划和手术置入的准确性。","authors":"Adli M.Q. Al-Gazzawi ,&nbsp;Vanessa Knode ,&nbsp;Bjorn Ludwig ,&nbsp;Alaa Othman ,&nbsp;Angelo Salamini ,&nbsp;Nikolaos Pandis ,&nbsp;Padhraig S. Fleming","doi":"10.1016/j.ajodo.2024.02.014","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The objective of this study was to investigate the accuracy of palatal miniscrew insertion, evaluating the effect of guide fabrication and surgical placement.</p></div><div><h3>Methods</h3><p>Guided insertion of bilateral paramedian palatal miniscrews was undertaken using Appliance Designer software (3Shape, Copenhagen, Denmark). A resin surgical guide (P Pro Surgical Guide; Straumann AG, Basel, Switzerland) was used. Superimposition of the miniscrew position relative to the digital design was undertaken using bespoke software (Inspect 3D module, OnyxCeph; Image Instruments GmbH, Chemnitz, Germany) to assess surgical inaccuracy. Miniscrew position relative to the surgical guide was also assessed to isolate the effect of planning inaccuracies. Both horizontal and vertical discrepancies were evaluated at both implant locations.</p></div><div><h3>Results</h3><p>Twenty-seven patients having bilateral palatal insertions were examined. Mean discrepancies were &lt;0.5 mm, both in the horizontal and vertical planes. The mean overall horizontal and vertical discrepancy between the digital design and final miniscrew position on the left side was 0.32 ± 0.15 mm and 0.34 ± 0.17 mm, respectively. The maximum horizontal discrepancy observed was 0.72 mm. No significant differences were observed in relation to the accuracy of mini-implant positioning on the basis of sidedness, either for horizontal (<em>P</em> = 0.29) or vertical (<em>P</em> = 0.86) discrepancy.</p></div><div><h3>Conclusions</h3><p>High levels of accuracy associated with guided insertion of paramedian palatal implants were recorded with mean discrepancies of less than 0.5 mm both in the horizontal and vertical planes. No difference in accuracy was noted between the left and right sides. Very minor levels of inaccuracy associated both with surgical techniques and surgical guide fabrication were recorded.</p></div>","PeriodicalId":50806,"journal":{"name":"American Journal of Orthodontics and Dentofacial Orthopedics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Midpalatal miniscrew insertion: The accuracy of digital planning and surgical placement\",\"authors\":\"Adli M.Q. Al-Gazzawi ,&nbsp;Vanessa Knode ,&nbsp;Bjorn Ludwig ,&nbsp;Alaa Othman ,&nbsp;Angelo Salamini ,&nbsp;Nikolaos Pandis ,&nbsp;Padhraig S. Fleming\",\"doi\":\"10.1016/j.ajodo.2024.02.014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>The objective of this study was to investigate the accuracy of palatal miniscrew insertion, evaluating the effect of guide fabrication and surgical placement.</p></div><div><h3>Methods</h3><p>Guided insertion of bilateral paramedian palatal miniscrews was undertaken using Appliance Designer software (3Shape, Copenhagen, Denmark). A resin surgical guide (P Pro Surgical Guide; Straumann AG, Basel, Switzerland) was used. Superimposition of the miniscrew position relative to the digital design was undertaken using bespoke software (Inspect 3D module, OnyxCeph; Image Instruments GmbH, Chemnitz, Germany) to assess surgical inaccuracy. Miniscrew position relative to the surgical guide was also assessed to isolate the effect of planning inaccuracies. Both horizontal and vertical discrepancies were evaluated at both implant locations.</p></div><div><h3>Results</h3><p>Twenty-seven patients having bilateral palatal insertions were examined. Mean discrepancies were &lt;0.5 mm, both in the horizontal and vertical planes. The mean overall horizontal and vertical discrepancy between the digital design and final miniscrew position on the left side was 0.32 ± 0.15 mm and 0.34 ± 0.17 mm, respectively. The maximum horizontal discrepancy observed was 0.72 mm. No significant differences were observed in relation to the accuracy of mini-implant positioning on the basis of sidedness, either for horizontal (<em>P</em> = 0.29) or vertical (<em>P</em> = 0.86) discrepancy.</p></div><div><h3>Conclusions</h3><p>High levels of accuracy associated with guided insertion of paramedian palatal implants were recorded with mean discrepancies of less than 0.5 mm both in the horizontal and vertical planes. No difference in accuracy was noted between the left and right sides. Very minor levels of inaccuracy associated both with surgical techniques and surgical guide fabrication were recorded.</p></div>\",\"PeriodicalId\":50806,\"journal\":{\"name\":\"American Journal of Orthodontics and Dentofacial Orthopedics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Orthodontics and Dentofacial Orthopedics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S088954062400132X\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Orthodontics and Dentofacial Orthopedics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S088954062400132X","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

方法使用 Appliance Designer 软件(3Shape,丹麦哥本哈根)引导插入双侧腭侧迷你螺钉。使用树脂手术导板(P Pro 手术导板;Straumann AG,瑞士巴塞尔)。使用定制软件(Inspect 3D 模块,OnyxCeph;Image Instruments GmbH,德国开姆尼茨)叠加微型螺钉相对于数字设计的位置,以评估手术的不准确性。此外,还评估了微型螺钉相对于手术导板的位置,以隔离规划不准确的影响。对两个种植体位置的水平和垂直偏差都进行了评估。水平面和垂直面的平均偏差均为 0.5 毫米。左侧数字设计和最终微型螺钉位置之间的平均水平和垂直差异分别为 0.32 ± 0.15 毫米和 0.34 ± 0.17 毫米。观察到的最大水平差异为 0.72 毫米。无论是水平偏差(P = 0.29)还是垂直偏差(P = 0.86),都没有观察到两侧微型种植体定位精度的明显差异。左右两侧的准确性没有差异。与手术技术和手术导板制作相关的误差都非常小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Midpalatal miniscrew insertion: The accuracy of digital planning and surgical placement

Introduction

The objective of this study was to investigate the accuracy of palatal miniscrew insertion, evaluating the effect of guide fabrication and surgical placement.

Methods

Guided insertion of bilateral paramedian palatal miniscrews was undertaken using Appliance Designer software (3Shape, Copenhagen, Denmark). A resin surgical guide (P Pro Surgical Guide; Straumann AG, Basel, Switzerland) was used. Superimposition of the miniscrew position relative to the digital design was undertaken using bespoke software (Inspect 3D module, OnyxCeph; Image Instruments GmbH, Chemnitz, Germany) to assess surgical inaccuracy. Miniscrew position relative to the surgical guide was also assessed to isolate the effect of planning inaccuracies. Both horizontal and vertical discrepancies were evaluated at both implant locations.

Results

Twenty-seven patients having bilateral palatal insertions were examined. Mean discrepancies were <0.5 mm, both in the horizontal and vertical planes. The mean overall horizontal and vertical discrepancy between the digital design and final miniscrew position on the left side was 0.32 ± 0.15 mm and 0.34 ± 0.17 mm, respectively. The maximum horizontal discrepancy observed was 0.72 mm. No significant differences were observed in relation to the accuracy of mini-implant positioning on the basis of sidedness, either for horizontal (P = 0.29) or vertical (P = 0.86) discrepancy.

Conclusions

High levels of accuracy associated with guided insertion of paramedian palatal implants were recorded with mean discrepancies of less than 0.5 mm both in the horizontal and vertical planes. No difference in accuracy was noted between the left and right sides. Very minor levels of inaccuracy associated both with surgical techniques and surgical guide fabrication were recorded.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.80
自引率
13.30%
发文量
432
审稿时长
66 days
期刊介绍: Published for more than 100 years, the American Journal of Orthodontics and Dentofacial Orthopedics remains the leading orthodontic resource. It is the official publication of the American Association of Orthodontists, its constituent societies, the American Board of Orthodontics, and the College of Diplomates of the American Board of Orthodontics. Each month its readers have access to original peer-reviewed articles that examine all phases of orthodontic treatment. Illustrated throughout, the publication includes tables, color photographs, and statistical data. Coverage includes successful diagnostic procedures, imaging techniques, bracket and archwire materials, extraction and impaction concerns, orthognathic surgery, TMJ disorders, removable appliances, and adult therapy.
期刊最新文献
Mesiodistal tip expression of mandibular anterior teeth in patients with mandibular incisor extraction treated with Invisalign aligners. Directly printed aligner therapy: A 12-month evaluation of application and effectiveness. The periodontal ligament-periosteum sandwich hypothesis: A thought experiment on fenestrations and dehiscences. Comparison of microbial adhesion and biofilm formation on different orthodontic aligners. Evaluating anchorage and torque control in adolescent patients with Class II Division 1 malocclusion among 3 appliances.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1