{"title":"采用残端保留移植物采集技术进行前交叉韧带重建后,内侧腘绳肌腱再生的解剖插入率更高:磁共振成像评估的前瞻性、随机、双盲临床试验","authors":"","doi":"10.1016/j.jisako.2024.04.013","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective(s)</h3><p>The purpose of this study was to compare the regeneration of semitendinosus and gracilis tendons from two different graft harvesting techniques, which are the stump preservation and conventional graft harvesting techniques. We hypothesised that the stump preservation graft harvesting technique, which preserved the distal attachment of tendons at their insertion, would facilitate anatomical regeneration to the pes anserinus.</p></div><div><h3>Methods</h3><p>This is a prospective, randomised, double-blinded study whereby thirty consecutive patients who underwent single bundle anterior cruciate ligament reconstruction with ipsilateral semitendinosus and gracilis autografts were recruited. The patients were randomly assigned to the stump preservation group (14 patients) or conventional group (16 patients). Magnetic resonance imaging (MRI) evaluation was performed preoperatively and at six months post-operatively.</p></div><div><h3>Results</h3><p>At 6-month follow-up, MRI evaluations showed a higher percentage of insertion of regenerated semitendinosus and gracilis at the pes anserinus in the stump preservation group (75.0%) than that in the conventional group (68.8%). There was a significantly higher proximal shift of the musculotendinous junction of semitendinosus (5.70 cm versus 3.36 cm, p = 0.029) and gracilis (5.28 cm versus 3.16 cm, p = 0.045) in the conventional group post-operatively.</p></div><div><h3>Conclusion</h3><p>The stump preservation technique yields a higher percentage of anatomical insertion of regenerated tendons and a lesser amount of proximal shift of the musculotendinous junction.</p></div><div><h3>Level of Evidence</h3><p>III – Prospective study with up to two negative criteria.</p></div>","PeriodicalId":36847,"journal":{"name":"Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S205977542400083X/pdfft?md5=496328b19330d7be1c054ced445e78c7&pid=1-s2.0-S205977542400083X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Higher rates of anatomical insertion of medial hamstring tendon regeneration post-anterior cruciate ligament reconstruction with stump preservation graft harvesting technique: A prospective, randomised, double-blinded clinical trial with magnetic resonance imaging evaluation\",\"authors\":\"\",\"doi\":\"10.1016/j.jisako.2024.04.013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective(s)</h3><p>The purpose of this study was to compare the regeneration of semitendinosus and gracilis tendons from two different graft harvesting techniques, which are the stump preservation and conventional graft harvesting techniques. We hypothesised that the stump preservation graft harvesting technique, which preserved the distal attachment of tendons at their insertion, would facilitate anatomical regeneration to the pes anserinus.</p></div><div><h3>Methods</h3><p>This is a prospective, randomised, double-blinded study whereby thirty consecutive patients who underwent single bundle anterior cruciate ligament reconstruction with ipsilateral semitendinosus and gracilis autografts were recruited. The patients were randomly assigned to the stump preservation group (14 patients) or conventional group (16 patients). Magnetic resonance imaging (MRI) evaluation was performed preoperatively and at six months post-operatively.</p></div><div><h3>Results</h3><p>At 6-month follow-up, MRI evaluations showed a higher percentage of insertion of regenerated semitendinosus and gracilis at the pes anserinus in the stump preservation group (75.0%) than that in the conventional group (68.8%). There was a significantly higher proximal shift of the musculotendinous junction of semitendinosus (5.70 cm versus 3.36 cm, p = 0.029) and gracilis (5.28 cm versus 3.16 cm, p = 0.045) in the conventional group post-operatively.</p></div><div><h3>Conclusion</h3><p>The stump preservation technique yields a higher percentage of anatomical insertion of regenerated tendons and a lesser amount of proximal shift of the musculotendinous junction.</p></div><div><h3>Level of Evidence</h3><p>III – Prospective study with up to two negative criteria.</p></div>\",\"PeriodicalId\":36847,\"journal\":{\"name\":\"Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S205977542400083X/pdfft?md5=496328b19330d7be1c054ced445e78c7&pid=1-s2.0-S205977542400083X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S205977542400083X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S205977542400083X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Higher rates of anatomical insertion of medial hamstring tendon regeneration post-anterior cruciate ligament reconstruction with stump preservation graft harvesting technique: A prospective, randomised, double-blinded clinical trial with magnetic resonance imaging evaluation
Objective(s)
The purpose of this study was to compare the regeneration of semitendinosus and gracilis tendons from two different graft harvesting techniques, which are the stump preservation and conventional graft harvesting techniques. We hypothesised that the stump preservation graft harvesting technique, which preserved the distal attachment of tendons at their insertion, would facilitate anatomical regeneration to the pes anserinus.
Methods
This is a prospective, randomised, double-blinded study whereby thirty consecutive patients who underwent single bundle anterior cruciate ligament reconstruction with ipsilateral semitendinosus and gracilis autografts were recruited. The patients were randomly assigned to the stump preservation group (14 patients) or conventional group (16 patients). Magnetic resonance imaging (MRI) evaluation was performed preoperatively and at six months post-operatively.
Results
At 6-month follow-up, MRI evaluations showed a higher percentage of insertion of regenerated semitendinosus and gracilis at the pes anserinus in the stump preservation group (75.0%) than that in the conventional group (68.8%). There was a significantly higher proximal shift of the musculotendinous junction of semitendinosus (5.70 cm versus 3.36 cm, p = 0.029) and gracilis (5.28 cm versus 3.16 cm, p = 0.045) in the conventional group post-operatively.
Conclusion
The stump preservation technique yields a higher percentage of anatomical insertion of regenerated tendons and a lesser amount of proximal shift of the musculotendinous junction.
Level of Evidence
III – Prospective study with up to two negative criteria.