采用硅学方法分析髋臼杯抬高对髋关节假体接触的影响以及在常规步态活动下不同微间隙和髋臼杯倾角的失效分析

IF 1.1 4区 医学 Q3 ORTHOPEDICS Indian Journal of Orthopaedics Pub Date : 2024-04-29 DOI:10.1007/s43465-024-01146-y
R. Nithyaprakash, S. Shankar, R. Naveenkumar, A. J. Kirthik Raja, R. Gokul Anand, G. Abbas, Chander Prakash, Alokesh Pramanik, Animesh Kumar Basak
{"title":"采用硅学方法分析髋臼杯抬高对髋关节假体接触的影响以及在常规步态活动下不同微间隙和髋臼杯倾角的失效分析","authors":"R. Nithyaprakash, S. Shankar, R. Naveenkumar, A. J. Kirthik Raja, R. Gokul Anand, G. Abbas, Chander Prakash, Alokesh Pramanik, Animesh Kumar Basak","doi":"10.1007/s43465-024-01146-y","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Objectives</h3><p>The acetabular cup design plays a critical role in reducing contact stress between femur head acetabular cup. Many studies used ellipsoidal and spheroidal geometry in acetabular cup design to effectively reduce contact stress. The present study focuses on elevated acetabular cup rim with round corner design to reduce contact stress with round corner geometry.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>The cobalt chromium femur head and cup are considered for finite element (FE) model of hip resurfacing. The gait loads of routine activities of humans like normal walking, stair ascending and descending and sitting down and getting up gait activities are applied to the developed 3D FE model. Five microseparations of 0.5, 1, 1.5, 2 and 2.5 mm are considered in the present study. The acetabular cup inclination angle considered for this study are 35°, 45°, 55°, 65° and 75°. The contact stress and von Mises stress plot for each gait activities under these microseparations are analyzed for betterment of longevity of implants.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>Overall elevated cup rim design helped in reducing contact stress to a greater extent than conventional cup with different geometries. Also, the predicted von Mises stress for all the parameters considered in the current study are well within the yield strength of CoCr material. Therefore, elevated cup rim could be used as a better alternative to spline and, ellipsoidal and circular geometries of cup.</p>","PeriodicalId":13338,"journal":{"name":"Indian Journal of Orthopaedics","volume":"23 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Elevated Acetabular Cup on Contact and Failure Analysis in Hip Implants for Different Microseparations and Cup Inclinations Under Routine Gait Activities Using In Silico Approach\",\"authors\":\"R. Nithyaprakash, S. Shankar, R. Naveenkumar, A. J. Kirthik Raja, R. Gokul Anand, G. Abbas, Chander Prakash, Alokesh Pramanik, Animesh Kumar Basak\",\"doi\":\"10.1007/s43465-024-01146-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Objectives</h3><p>The acetabular cup design plays a critical role in reducing contact stress between femur head acetabular cup. Many studies used ellipsoidal and spheroidal geometry in acetabular cup design to effectively reduce contact stress. The present study focuses on elevated acetabular cup rim with round corner design to reduce contact stress with round corner geometry.</p><h3 data-test=\\\"abstract-sub-heading\\\">Methods</h3><p>The cobalt chromium femur head and cup are considered for finite element (FE) model of hip resurfacing. The gait loads of routine activities of humans like normal walking, stair ascending and descending and sitting down and getting up gait activities are applied to the developed 3D FE model. Five microseparations of 0.5, 1, 1.5, 2 and 2.5 mm are considered in the present study. The acetabular cup inclination angle considered for this study are 35°, 45°, 55°, 65° and 75°. The contact stress and von Mises stress plot for each gait activities under these microseparations are analyzed for betterment of longevity of implants.</p><h3 data-test=\\\"abstract-sub-heading\\\">Results</h3><p>Overall elevated cup rim design helped in reducing contact stress to a greater extent than conventional cup with different geometries. Also, the predicted von Mises stress for all the parameters considered in the current study are well within the yield strength of CoCr material. Therefore, elevated cup rim could be used as a better alternative to spline and, ellipsoidal and circular geometries of cup.</p>\",\"PeriodicalId\":13338,\"journal\":{\"name\":\"Indian Journal of Orthopaedics\",\"volume\":\"23 1\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Orthopaedics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s43465-024-01146-y\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s43465-024-01146-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的髋臼杯的设计在降低股骨头与髋臼杯之间的接触应力方面起着至关重要的作用。许多研究在髋臼杯设计中使用了椭圆形和球形几何形状,以有效降低接触应力。本研究的重点是采用圆角设计的升高髋臼杯缘,以减少圆角几何形状的接触应力。方法将钴铬合金股骨头和髋臼杯作为髋关节置换的有限元(FE)模型。人体日常活动的步态载荷,如正常行走、上下楼梯、坐下和起身等步态活动,都被应用到所开发的三维有限元模型中。本研究考虑了 0.5 毫米、1 毫米、1.5 毫米、2 毫米和 2.5 毫米的五个微间隙。本研究考虑的髋臼杯倾角分别为 35°、45°、55°、65° 和 75°。结果总体而言,与不同几何形状的传统髋臼杯相比,升高的髋臼杯边缘设计有助于更大程度地降低接触应力。此外,本研究中考虑的所有参数的预测 von Mises 应力都在 CoCr 材料的屈服强度范围内。因此,隆起的杯缘可以更好地替代花键形、椭圆形和圆形几何形状的杯缘。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Elevated Acetabular Cup on Contact and Failure Analysis in Hip Implants for Different Microseparations and Cup Inclinations Under Routine Gait Activities Using In Silico Approach

Objectives

The acetabular cup design plays a critical role in reducing contact stress between femur head acetabular cup. Many studies used ellipsoidal and spheroidal geometry in acetabular cup design to effectively reduce contact stress. The present study focuses on elevated acetabular cup rim with round corner design to reduce contact stress with round corner geometry.

Methods

The cobalt chromium femur head and cup are considered for finite element (FE) model of hip resurfacing. The gait loads of routine activities of humans like normal walking, stair ascending and descending and sitting down and getting up gait activities are applied to the developed 3D FE model. Five microseparations of 0.5, 1, 1.5, 2 and 2.5 mm are considered in the present study. The acetabular cup inclination angle considered for this study are 35°, 45°, 55°, 65° and 75°. The contact stress and von Mises stress plot for each gait activities under these microseparations are analyzed for betterment of longevity of implants.

Results

Overall elevated cup rim design helped in reducing contact stress to a greater extent than conventional cup with different geometries. Also, the predicted von Mises stress for all the parameters considered in the current study are well within the yield strength of CoCr material. Therefore, elevated cup rim could be used as a better alternative to spline and, ellipsoidal and circular geometries of cup.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
185
审稿时长
9 months
期刊介绍: IJO welcomes articles that contribute to Orthopaedic knowledge from India and overseas. We publish articles dealing with clinical orthopaedics and basic research in orthopaedic surgery. Articles are accepted only for exclusive publication in the Indian Journal of Orthopaedics. Previously published articles, articles which are in peer-reviewed electronic publications in other journals, are not accepted by the Journal. Published articles and illustrations become the property of the Journal. The copyright remains with the journal. Studies must be carried out in accordance with World Medical Association Declaration of Helsinki.
期刊最新文献
Technology Update in Management of Multi-Ligament Knee Injuries. From the Guest Editors: Unraveling the Complexities of Multiligament Knee Injuries-A Global Endeavor. Strategies for Preventing Tunnel Convergence in Multiligament Knee Injury Reconstructions. Adjustable Loop Fixation in Multi-ligament Knee Injuries: A Technical Note. Clinical Results of Isolated MCL Grade III Injury in Acute and Chronic Setting: Systematic Review and Meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1