Gaëlle Hugon, Hans Adriaensen, Mélody Wintrebert, Laurent Arnould, Jean-Michel Serfaty, Philippe Robert
{"title":"评估钆喷酸醇在健康兔子和猪磁共振血管造影中的对比增强性能","authors":"Gaëlle Hugon, Hans Adriaensen, Mélody Wintrebert, Laurent Arnould, Jean-Michel Serfaty, Philippe Robert","doi":"10.1097/RLI.0000000000001083","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Unexpected accumulations of gadolinium in various organs were reported after the administration of gadolinium-based contrast agents, making desirable to reduce the dose while maintaining equivalent diagnostic performance. The aim of this study was to evaluate the contrast enhancement performance of high relaxivity gadopiclenol compared with gadoterate meglumine in abdominal contrast-enhanced magnetic resonance angiography (CE-MRA).</p><p><strong>Materials and methods: </strong>In a first study in healthy rabbits, axial 3D gradient echo sequences were applied at 4.7 T to study arterial enhancement as a function of gadopiclenol dose (0.025, 0.05, 0.075, and 0.1 mmol Gd/kg) or gadoterate meglumine at 0.1 mmol Gd/kg (n = 5-6/group). The increase in signal-to-noise ratio (ΔSNR) in the aorta at the first pass was measured and compared. In a second, crossover study in 6 healthy pigs, abdominal CE-MRA sequences were acquired at 3 T with gadopiclenol at 0.05 mmol Gd/kg or gadoterate meglumine at 0.1 mmol Gd/kg at a 1-week interval. Quantitatively on the maximum intensity projection (MIP) images, the mean MIP SNR within the aorta of both groups was compared. Qualitatively, a blinded comparison of the angiograms was performed by an experienced radiologist to determine the preferred contrast agent.</p><p><strong>Results: </strong>In the rabbit, ∆SNR is linearly correlated with the gadopiclenol dose ( P = 0.0010). Compared with gadoterate meglumine 0.1 mmol Gd/kg, an increase in the ∆SNR is observed after 0.05, 0.075, and 0.1 mmol Gd/kg of gadopiclenol (+63% P = 0.0731, +78% P = 0.0081, and +72% P = 0.0773, respectively), whereas at 0.025 mmol Gd/kg, ∆SNR is in the same range as with gadoterate meglumine 0.1 mmol Gd/kg (+15% P > 0.9999). In pigs, contrast enhancement after gadopiclenol at 0.05 mmol/kg is +22% superior to MIP SNR after gadoterate meglumine at 0.1 mmol Gd/kg ( P = 0.3095). Qualitatively, a preference was shown for gadopiclenol images (3/6) over the gadoterate meglumine examinations (1/6), with no preference being shown for the remainder (2/6).</p><p><strong>Conclusions: </strong>First-pass CE-MRA is feasible with gadopiclenol at 0.05 mmol Gd/kg with at least the same arterial signal enhancement and image quality as gadoterate meglumine at 0.1 mmol Gd/kg.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":"614-621"},"PeriodicalIF":7.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Contrast Enhancement Performance of Gadopiclenol for Magnetic Resonance Angiography in Healthy Rabbits and Pigs.\",\"authors\":\"Gaëlle Hugon, Hans Adriaensen, Mélody Wintrebert, Laurent Arnould, Jean-Michel Serfaty, Philippe Robert\",\"doi\":\"10.1097/RLI.0000000000001083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Unexpected accumulations of gadolinium in various organs were reported after the administration of gadolinium-based contrast agents, making desirable to reduce the dose while maintaining equivalent diagnostic performance. The aim of this study was to evaluate the contrast enhancement performance of high relaxivity gadopiclenol compared with gadoterate meglumine in abdominal contrast-enhanced magnetic resonance angiography (CE-MRA).</p><p><strong>Materials and methods: </strong>In a first study in healthy rabbits, axial 3D gradient echo sequences were applied at 4.7 T to study arterial enhancement as a function of gadopiclenol dose (0.025, 0.05, 0.075, and 0.1 mmol Gd/kg) or gadoterate meglumine at 0.1 mmol Gd/kg (n = 5-6/group). The increase in signal-to-noise ratio (ΔSNR) in the aorta at the first pass was measured and compared. In a second, crossover study in 6 healthy pigs, abdominal CE-MRA sequences were acquired at 3 T with gadopiclenol at 0.05 mmol Gd/kg or gadoterate meglumine at 0.1 mmol Gd/kg at a 1-week interval. Quantitatively on the maximum intensity projection (MIP) images, the mean MIP SNR within the aorta of both groups was compared. Qualitatively, a blinded comparison of the angiograms was performed by an experienced radiologist to determine the preferred contrast agent.</p><p><strong>Results: </strong>In the rabbit, ∆SNR is linearly correlated with the gadopiclenol dose ( P = 0.0010). Compared with gadoterate meglumine 0.1 mmol Gd/kg, an increase in the ∆SNR is observed after 0.05, 0.075, and 0.1 mmol Gd/kg of gadopiclenol (+63% P = 0.0731, +78% P = 0.0081, and +72% P = 0.0773, respectively), whereas at 0.025 mmol Gd/kg, ∆SNR is in the same range as with gadoterate meglumine 0.1 mmol Gd/kg (+15% P > 0.9999). In pigs, contrast enhancement after gadopiclenol at 0.05 mmol/kg is +22% superior to MIP SNR after gadoterate meglumine at 0.1 mmol Gd/kg ( P = 0.3095). Qualitatively, a preference was shown for gadopiclenol images (3/6) over the gadoterate meglumine examinations (1/6), with no preference being shown for the remainder (2/6).</p><p><strong>Conclusions: </strong>First-pass CE-MRA is feasible with gadopiclenol at 0.05 mmol Gd/kg with at least the same arterial signal enhancement and image quality as gadoterate meglumine at 0.1 mmol Gd/kg.</p>\",\"PeriodicalId\":14486,\"journal\":{\"name\":\"Investigative Radiology\",\"volume\":\" \",\"pages\":\"614-621\"},\"PeriodicalIF\":7.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Investigative Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RLI.0000000000001083\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001083","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Evaluation of the Contrast Enhancement Performance of Gadopiclenol for Magnetic Resonance Angiography in Healthy Rabbits and Pigs.
Objectives: Unexpected accumulations of gadolinium in various organs were reported after the administration of gadolinium-based contrast agents, making desirable to reduce the dose while maintaining equivalent diagnostic performance. The aim of this study was to evaluate the contrast enhancement performance of high relaxivity gadopiclenol compared with gadoterate meglumine in abdominal contrast-enhanced magnetic resonance angiography (CE-MRA).
Materials and methods: In a first study in healthy rabbits, axial 3D gradient echo sequences were applied at 4.7 T to study arterial enhancement as a function of gadopiclenol dose (0.025, 0.05, 0.075, and 0.1 mmol Gd/kg) or gadoterate meglumine at 0.1 mmol Gd/kg (n = 5-6/group). The increase in signal-to-noise ratio (ΔSNR) in the aorta at the first pass was measured and compared. In a second, crossover study in 6 healthy pigs, abdominal CE-MRA sequences were acquired at 3 T with gadopiclenol at 0.05 mmol Gd/kg or gadoterate meglumine at 0.1 mmol Gd/kg at a 1-week interval. Quantitatively on the maximum intensity projection (MIP) images, the mean MIP SNR within the aorta of both groups was compared. Qualitatively, a blinded comparison of the angiograms was performed by an experienced radiologist to determine the preferred contrast agent.
Results: In the rabbit, ∆SNR is linearly correlated with the gadopiclenol dose ( P = 0.0010). Compared with gadoterate meglumine 0.1 mmol Gd/kg, an increase in the ∆SNR is observed after 0.05, 0.075, and 0.1 mmol Gd/kg of gadopiclenol (+63% P = 0.0731, +78% P = 0.0081, and +72% P = 0.0773, respectively), whereas at 0.025 mmol Gd/kg, ∆SNR is in the same range as with gadoterate meglumine 0.1 mmol Gd/kg (+15% P > 0.9999). In pigs, contrast enhancement after gadopiclenol at 0.05 mmol/kg is +22% superior to MIP SNR after gadoterate meglumine at 0.1 mmol Gd/kg ( P = 0.3095). Qualitatively, a preference was shown for gadopiclenol images (3/6) over the gadoterate meglumine examinations (1/6), with no preference being shown for the remainder (2/6).
Conclusions: First-pass CE-MRA is feasible with gadopiclenol at 0.05 mmol Gd/kg with at least the same arterial signal enhancement and image quality as gadoterate meglumine at 0.1 mmol Gd/kg.
期刊介绍:
Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.