模拟 T2 加权流体衰减反转恢复磁共振图像的采集偏移,对人工智能分割网络进行压力测试。

IF 1.9 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Medical Imaging Pub Date : 2024-03-01 Epub Date: 2024-04-24 DOI:10.1117/1.JMI.11.2.024013
Christiane Posselt, Mehmet Yigit Avci, Mehmet Yigitsoy, Patrick Schuenke, Christoph Kolbitsch, Tobias Schaeffter, Stefanie Remmele
{"title":"模拟 T2 加权流体衰减反转恢复磁共振图像的采集偏移,对人工智能分割网络进行压力测试。","authors":"Christiane Posselt, Mehmet Yigit Avci, Mehmet Yigitsoy, Patrick Schuenke, Christoph Kolbitsch, Tobias Schaeffter, Stefanie Remmele","doi":"10.1117/1.JMI.11.2.024013","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To provide a simulation framework for routine neuroimaging test data, which allows for \"stress testing\" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid-attenuated inversion recovery magnetic resonance imaging protocols.</p><p><strong>Approach: </strong>The approach simulates \"acquisition shift derivatives\" of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art multiple sclerosis lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI).</p><p><strong>Results: </strong>The differences between real and simulated images range up to 19% in gray and white matter for extreme parameter settings. For the segmentation networks under test, the F1 score dependency on TE and TI can be well described by quadratic model functions (<math><mrow><msup><mi>R</mi><mn>2</mn></msup><mo>></mo><mn>0.9</mn></mrow></math>). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI.</p><p><strong>Conclusions: </strong>We show that these deviations are in the range of values as may be caused by erroneous or individual differences in relaxation times as described by literature. The coefficients of the F1 model function allow for a quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with a low baseline signal (like cerebrospinal fluid) and when the protocol contains contrast-affecting measures that cannot be modeled due to missing information in the DICOM header.</p>","PeriodicalId":47707,"journal":{"name":"Journal of Medical Imaging","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11042016/pdf/","citationCount":"0","resultStr":"{\"title\":\"Simulation of acquisition shifts in T2 weighted fluid-attenuated inversion recovery magnetic resonance images to stress test artificial intelligence segmentation networks.\",\"authors\":\"Christiane Posselt, Mehmet Yigit Avci, Mehmet Yigitsoy, Patrick Schuenke, Christoph Kolbitsch, Tobias Schaeffter, Stefanie Remmele\",\"doi\":\"10.1117/1.JMI.11.2.024013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To provide a simulation framework for routine neuroimaging test data, which allows for \\\"stress testing\\\" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid-attenuated inversion recovery magnetic resonance imaging protocols.</p><p><strong>Approach: </strong>The approach simulates \\\"acquisition shift derivatives\\\" of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art multiple sclerosis lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI).</p><p><strong>Results: </strong>The differences between real and simulated images range up to 19% in gray and white matter for extreme parameter settings. For the segmentation networks under test, the F1 score dependency on TE and TI can be well described by quadratic model functions (<math><mrow><msup><mi>R</mi><mn>2</mn></msup><mo>></mo><mn>0.9</mn></mrow></math>). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI.</p><p><strong>Conclusions: </strong>We show that these deviations are in the range of values as may be caused by erroneous or individual differences in relaxation times as described by literature. The coefficients of the F1 model function allow for a quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with a low baseline signal (like cerebrospinal fluid) and when the protocol contains contrast-affecting measures that cannot be modeled due to missing information in the DICOM header.</p>\",\"PeriodicalId\":47707,\"journal\":{\"name\":\"Journal of Medical Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11042016/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JMI.11.2.024013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JMI.11.2.024013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:为常规神经成像测试数据提供一个模拟框架,以便针对临床实践中常见的 T2 加权(T2w)流体衰减反转恢复磁共振成像协议的采集偏移对深度分割网络进行 "压力测试":方法:该方法根据磁共振信号方程模拟磁共振图像的 "采集偏移导数"。实验包括通过真实磁共振扫描对模拟图像进行验证,以及对最先进的多发性硬化病灶分割网络进行示例压力测试,以探索一个通用模型函数,描述 F1 分数与对比度影响序列参数回波时间(TE)和反转时间(TI)的关系:结果:在极端参数设置下,灰质和白质的真实图像与模拟图像之间的差异高达 19%。对于测试中的分割网络,F1 分数与 TE 和 TI 的关系可以用二次模型函数很好地描述(R2>0.9)。模型函数的系数表明,TE 的变化比 TI 对模型性能的影响更大:我们的研究表明,这些偏差在文献描述的弛豫时间错误或个体差异可能造成的数值范围内。F1 模型函数的系数可对 TE 和 TI 的影响进行定量比较。局限性主要来自于基线信号较低的组织(如脑脊液),以及由于 DICOM 标头信息缺失而无法建模的对比度影响措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulation of acquisition shifts in T2 weighted fluid-attenuated inversion recovery magnetic resonance images to stress test artificial intelligence segmentation networks.

Purpose: To provide a simulation framework for routine neuroimaging test data, which allows for "stress testing" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid-attenuated inversion recovery magnetic resonance imaging protocols.

Approach: The approach simulates "acquisition shift derivatives" of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art multiple sclerosis lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI).

Results: The differences between real and simulated images range up to 19% in gray and white matter for extreme parameter settings. For the segmentation networks under test, the F1 score dependency on TE and TI can be well described by quadratic model functions (R2>0.9). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI.

Conclusions: We show that these deviations are in the range of values as may be caused by erroneous or individual differences in relaxation times as described by literature. The coefficients of the F1 model function allow for a quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with a low baseline signal (like cerebrospinal fluid) and when the protocol contains contrast-affecting measures that cannot be modeled due to missing information in the DICOM header.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Imaging
Journal of Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
4.20%
发文量
0
期刊介绍: JMI covers fundamental and translational research, as well as applications, focused on medical imaging, which continue to yield physical and biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal. The scope of JMI includes: Imaging physics, Tomographic reconstruction algorithms (such as those in CT and MRI), Image processing and deep learning, Computer-aided diagnosis and quantitative image analysis, Visualization and modeling, Picture archiving and communications systems (PACS), Image perception and observer performance, Technology assessment, Ultrasonic imaging, Image-guided procedures, Digital pathology, Biomedical applications of biomedical imaging. JMI allows for the peer-reviewed communication and archiving of scientific developments, translational and clinical applications, reviews, and recommendations for the field.
期刊最新文献
In-silico study of the impact of system design parameters on microcalcification detection in wide-angle digital breast tomosynthesis. Estimation of the absorbed dose in simultaneous digital breast tomosynthesis and mechanical imaging. Breathing motion compensation in chest tomosynthesis: evaluation of the effect on image quality and presence of artifacts. Impact of patient habitus and acquisition protocol on iodine quantification in dual-source photon-counting computed tomography. Spectral optimization using fast kV switching and filtration for photon counting CT with realistic detector responses: a simulation study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1