流式细胞术检测中低收入国家 B 型急性淋巴细胞白血病的脑膜浸润。

IF 2.3 3区 医学 Q3 MEDICAL LABORATORY TECHNOLOGY Cytometry Part B: Clinical Cytometry Pub Date : 2024-05-06 DOI:10.1002/cyto.b.22179
Eya Anane, Fatma Ben Lakhal, Sarra Fekih Salem, Ons Ghali, Emna Feki, Yosr Ben Abdennebi, Marwa Bahri, Emna Azza, Lamia Aissaoui, Wijden El Borgi, Emna Gouider
{"title":"流式细胞术检测中低收入国家 B 型急性淋巴细胞白血病的脑膜浸润。","authors":"Eya Anane,&nbsp;Fatma Ben Lakhal,&nbsp;Sarra Fekih Salem,&nbsp;Ons Ghali,&nbsp;Emna Feki,&nbsp;Yosr Ben Abdennebi,&nbsp;Marwa Bahri,&nbsp;Emna Azza,&nbsp;Lamia Aissaoui,&nbsp;Wijden El Borgi,&nbsp;Emna Gouider","doi":"10.1002/cyto.b.22179","DOIUrl":null,"url":null,"abstract":"<p>Meningeal infiltration in children with B acute lymphoblastic leukemia is one of the most serious complications. Timely diagnosis not only significantly enhances treatment efficacy but also leads to improve patient outcome and reduce risk of relapse. This is particularly crucial in low to middle income countries facing health constraints, where optimizing resources is essential. Conventional cytology (CC) study of cerebrospinal fluid (CSF) is considered in different countries to be the Gold-standard despite its low sensitivity (&lt; 50%). The study of CSF by multiparametric flow cytometry (MFC) appears to be an alternative. The aim of our study was to assess MFC analytical performance compared with CC. Our cross sectional study was conducted over a six-month period in the biological hematology department. CSF samples underwent analysis for the presence of blasts using both CC and MFC. Cytological slides of the CSF were prepared by cytocentrifugation in a Shandon Cytospin 4™. Flow cytometric analysis was performed on the BD FACSLyric™ flow cytometer. All statistical analyses were performed using SPSS version 21.0 (SPSS Inc.). Agreement between the two methods was made using the Kappa index and χ<sup>2</sup> test. This study was approved by the local ethics committee. Sixty CSF samples from 39 children with B acute lymphoblastic leukemia were analyzed. Meningeal infiltration was detected respectively in 20% of cases by MFC and 5% of cases by CC, with a significant difference <i>p</i> = 0.006. Comparing the two methods, the Kappa coefficient was 0.35, indicating weak agreement between the two methods. Moreover, MFC positivity was higher even for hypocellular samples. Of the 51 hypocellular samples, eight were positive by MFC while they were negative by CC. MFC shows better sensitivity while retaining good specificity for the detection of meningeal involvement. MFC could therefore be a complementary method to CC for detecting blast cells in the central nervous system.</p>","PeriodicalId":10883,"journal":{"name":"Cytometry Part B: Clinical Cytometry","volume":"106 5","pages":"405-411"},"PeriodicalIF":2.3000,"publicationDate":"2024-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flow cytometry for meningeal infiltration in B acute lymphoblastic leukemia in a low middle income country\",\"authors\":\"Eya Anane,&nbsp;Fatma Ben Lakhal,&nbsp;Sarra Fekih Salem,&nbsp;Ons Ghali,&nbsp;Emna Feki,&nbsp;Yosr Ben Abdennebi,&nbsp;Marwa Bahri,&nbsp;Emna Azza,&nbsp;Lamia Aissaoui,&nbsp;Wijden El Borgi,&nbsp;Emna Gouider\",\"doi\":\"10.1002/cyto.b.22179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Meningeal infiltration in children with B acute lymphoblastic leukemia is one of the most serious complications. Timely diagnosis not only significantly enhances treatment efficacy but also leads to improve patient outcome and reduce risk of relapse. This is particularly crucial in low to middle income countries facing health constraints, where optimizing resources is essential. Conventional cytology (CC) study of cerebrospinal fluid (CSF) is considered in different countries to be the Gold-standard despite its low sensitivity (&lt; 50%). The study of CSF by multiparametric flow cytometry (MFC) appears to be an alternative. The aim of our study was to assess MFC analytical performance compared with CC. Our cross sectional study was conducted over a six-month period in the biological hematology department. CSF samples underwent analysis for the presence of blasts using both CC and MFC. Cytological slides of the CSF were prepared by cytocentrifugation in a Shandon Cytospin 4™. Flow cytometric analysis was performed on the BD FACSLyric™ flow cytometer. All statistical analyses were performed using SPSS version 21.0 (SPSS Inc.). Agreement between the two methods was made using the Kappa index and χ<sup>2</sup> test. This study was approved by the local ethics committee. Sixty CSF samples from 39 children with B acute lymphoblastic leukemia were analyzed. Meningeal infiltration was detected respectively in 20% of cases by MFC and 5% of cases by CC, with a significant difference <i>p</i> = 0.006. Comparing the two methods, the Kappa coefficient was 0.35, indicating weak agreement between the two methods. Moreover, MFC positivity was higher even for hypocellular samples. Of the 51 hypocellular samples, eight were positive by MFC while they were negative by CC. MFC shows better sensitivity while retaining good specificity for the detection of meningeal involvement. MFC could therefore be a complementary method to CC for detecting blast cells in the central nervous system.</p>\",\"PeriodicalId\":10883,\"journal\":{\"name\":\"Cytometry Part B: Clinical Cytometry\",\"volume\":\"106 5\",\"pages\":\"405-411\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cytometry Part B: Clinical Cytometry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cyto.b.22179\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cytometry Part B: Clinical Cytometry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cyto.b.22179","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

B 型急性淋巴细胞白血病患儿的脑膜浸润是最严重的并发症之一。及时诊断不仅能显著提高治疗效果,还能改善患者预后,降低复发风险。这对于面临医疗限制的中低收入国家尤为重要,因为这些国家必须优化资源。脑脊液(CSF)的常规细胞学(CC)研究在不同国家被视为黄金标准,尽管其敏感性较低(2 检验)。本研究获得了当地伦理委员会的批准。本研究分析了 39 名 B 型急性淋巴细胞白血病患儿的 60 份脑脊液样本。MFC和CC分别有20%和5%的病例检测到脑膜浸润,差异显著(P = 0.006)。比较两种方法,卡帕系数为 0.35,表明两种方法的一致性较弱。此外,即使是低细胞样本,MFC 阳性率也较高。在 51 份低细胞样本中,有 8 份样本的 MFC 检测结果呈阳性,而 CC 检测结果呈阴性。MFC 在检测脑膜受累方面显示出更高的灵敏度,同时保留了良好的特异性。因此,MFC 可作为 CC 的补充方法,用于检测中枢神经系统中的爆炸细胞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Flow cytometry for meningeal infiltration in B acute lymphoblastic leukemia in a low middle income country

Meningeal infiltration in children with B acute lymphoblastic leukemia is one of the most serious complications. Timely diagnosis not only significantly enhances treatment efficacy but also leads to improve patient outcome and reduce risk of relapse. This is particularly crucial in low to middle income countries facing health constraints, where optimizing resources is essential. Conventional cytology (CC) study of cerebrospinal fluid (CSF) is considered in different countries to be the Gold-standard despite its low sensitivity (< 50%). The study of CSF by multiparametric flow cytometry (MFC) appears to be an alternative. The aim of our study was to assess MFC analytical performance compared with CC. Our cross sectional study was conducted over a six-month period in the biological hematology department. CSF samples underwent analysis for the presence of blasts using both CC and MFC. Cytological slides of the CSF were prepared by cytocentrifugation in a Shandon Cytospin 4™. Flow cytometric analysis was performed on the BD FACSLyric™ flow cytometer. All statistical analyses were performed using SPSS version 21.0 (SPSS Inc.). Agreement between the two methods was made using the Kappa index and χ2 test. This study was approved by the local ethics committee. Sixty CSF samples from 39 children with B acute lymphoblastic leukemia were analyzed. Meningeal infiltration was detected respectively in 20% of cases by MFC and 5% of cases by CC, with a significant difference p = 0.006. Comparing the two methods, the Kappa coefficient was 0.35, indicating weak agreement between the two methods. Moreover, MFC positivity was higher even for hypocellular samples. Of the 51 hypocellular samples, eight were positive by MFC while they were negative by CC. MFC shows better sensitivity while retaining good specificity for the detection of meningeal involvement. MFC could therefore be a complementary method to CC for detecting blast cells in the central nervous system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.80
自引率
32.40%
发文量
51
审稿时长
>12 weeks
期刊介绍: Cytometry Part B: Clinical Cytometry features original research reports, in-depth reviews and special issues that directly relate to and palpably impact clinical flow, mass and image-based cytometry. These may include clinical and translational investigations important in the diagnostic, prognostic and therapeutic management of patients. Thus, we welcome research papers from various disciplines related [but not limited to] hematopathologists, hematologists, immunologists and cell biologists with clinically relevant and innovative studies investigating individual-cell analytics and/or separations. In addition to the types of papers indicated above, we also welcome Letters to the Editor, describing case reports or important medical or technical topics relevant to our readership without the length and depth of a full original report.
期刊最新文献
Prospective feasibility of a minimal BH3 profiling assay in acute myeloid leukemia. PICALM::MLLT10 fusion gene positive acute myeloid leukemia with PHF6 mutation and presented with CD7 positive immunophenotype. SingletSeeker: an unsupervised clustering approach for automated singlet discrimination in cytometry. ClearLLab 10C reagents panel can be applied to analyze paucicellular samples by flow cytometry. Improved identification of clinically relevant Acute Leukemia subtypes using standardized EuroFlow panels versus non-standardized approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1