使用 IOLMaster 700 B-scan 图像测量体内晶状体形状:与相位测量法的比较。

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY Ophthalmic and Physiological Optics Pub Date : 2024-07-01 Epub Date: 2024-04-27 DOI:10.1111/opo.13319
Asik Pradhan, Rohan P J Hughes, Emily Pieterse, David A Atchison, Andrew Carkeet
{"title":"使用 IOLMaster 700 B-scan 图像测量体内晶状体形状:与相位测量法的比较。","authors":"Asik Pradhan, Rohan P J Hughes, Emily Pieterse, David A Atchison, Andrew Carkeet","doi":"10.1111/opo.13319","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study compared in vivo crystalline lens shape measurements using B-scan images from the IOLMaster 700 with phakometry.</p><p><strong>Methods: </strong>Twenty-four young adult participants underwent IOLMaster 700 and phakometry measurements under cycloplegia (1% cyclopentolate). The IOLMaster 700 generated B-scan images along six meridians in 30° increments, which were analysed using custom MATLAB software to determine lens surface radii of curvature. Phakometry measurements were obtained using Purkinje images reflected from the lens surfaces.</p><p><strong>Results: </strong>The IOLMaster 700 image analysis method yielded a lower mean anterior lens surface spherical equivalent power (+6.20 D) than phakometry (+7.55 D); however, the two measurements were strongly correlated (R<sub>(21)</sub> = 0.97, p < 0.0001). The astigmatic power vectors (J<sub>0</sub> and J<sub>45</sub>) for the anterior lens surface were significantly higher for the IOLMaster 700 measurements, with only J<sub>0</sub> showing a significant moderate positive correlation (R<sub>(21)</sub> = 0.57, p = 0.005). For the posterior lens surface, the IOLMaster 700 measurements had a higher mean spherical power (+14.28 D) compared to phakometry (+13.70 D); however, a strong positive correlation (R<sub>(21)</sub> = 0.90, p < 0.0001) was observed. No significant correlations were noted for posterior lens surface astigmatic vectors (J<sub>0</sub> and J<sub>45</sub>). The IOLMaster 700 estimates for the equivalent lens mean spherical power were slightly lower than those for phakometry, with a mean difference of -0.72 D, and both methods were positively correlated (R<sub>(21)</sub> = 0.94, p < 0.0001).</p><p><strong>Conclusions: </strong>The findings demonstrate that IOLMaster 700 B-scan image analysis technique provides similar estimates of lens surface powers to phakometry. These results highlight the potential of the IOLMaster 700 to provide measurements of lens shape, informing future research and clinical use.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of in vivo lens shapes using IOLMaster 700 B-scan images: Comparison with phakometry.\",\"authors\":\"Asik Pradhan, Rohan P J Hughes, Emily Pieterse, David A Atchison, Andrew Carkeet\",\"doi\":\"10.1111/opo.13319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study compared in vivo crystalline lens shape measurements using B-scan images from the IOLMaster 700 with phakometry.</p><p><strong>Methods: </strong>Twenty-four young adult participants underwent IOLMaster 700 and phakometry measurements under cycloplegia (1% cyclopentolate). The IOLMaster 700 generated B-scan images along six meridians in 30° increments, which were analysed using custom MATLAB software to determine lens surface radii of curvature. Phakometry measurements were obtained using Purkinje images reflected from the lens surfaces.</p><p><strong>Results: </strong>The IOLMaster 700 image analysis method yielded a lower mean anterior lens surface spherical equivalent power (+6.20 D) than phakometry (+7.55 D); however, the two measurements were strongly correlated (R<sub>(21)</sub> = 0.97, p < 0.0001). The astigmatic power vectors (J<sub>0</sub> and J<sub>45</sub>) for the anterior lens surface were significantly higher for the IOLMaster 700 measurements, with only J<sub>0</sub> showing a significant moderate positive correlation (R<sub>(21)</sub> = 0.57, p = 0.005). For the posterior lens surface, the IOLMaster 700 measurements had a higher mean spherical power (+14.28 D) compared to phakometry (+13.70 D); however, a strong positive correlation (R<sub>(21)</sub> = 0.90, p < 0.0001) was observed. No significant correlations were noted for posterior lens surface astigmatic vectors (J<sub>0</sub> and J<sub>45</sub>). The IOLMaster 700 estimates for the equivalent lens mean spherical power were slightly lower than those for phakometry, with a mean difference of -0.72 D, and both methods were positively correlated (R<sub>(21)</sub> = 0.94, p < 0.0001).</p><p><strong>Conclusions: </strong>The findings demonstrate that IOLMaster 700 B-scan image analysis technique provides similar estimates of lens surface powers to phakometry. These results highlight the potential of the IOLMaster 700 to provide measurements of lens shape, informing future research and clinical use.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13319\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13319","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究比较了使用 IOLMaster 700 的 B-scan 图像和相位测量法进行的体内晶状体形状测量:二十四名年轻的成年参与者在环形麻痹(1% 环戊丙酸)下接受了 IOLMaster 700 和相位测量法的测量。IOLMaster 700 沿六条经线以 30° 为增量生成 B-scan 图像,使用定制的 MATLAB 软件对这些图像进行分析,以确定晶状体表面曲率半径。利用从晶状体表面反射的普金杰图像进行了法测定:IOLMaster 700 图像分析方法得出的晶状体前表面球面等效视力平均值(+6.20 D)低于法测法(+7.55 D);然而,两种测量方法具有很强的相关性(R(21) = 0.97,p 0 和 J45),IOLMaster 700 测量的晶状体前表面球面等效视力显著高于法测法,只有 J0 显示出显著的中度正相关性(R(21) = 0.57,p = 0.005)。对于晶状体后表面,IOLMaster 700 测量值的平均球面力(+14.28 D)高于相差测量值(+13.70 D);但是,两者之间有很强的正相关性(R(21) = 0.90,p 0 和 J45)。IOLMaster 700 估算的等效晶状体平均球面力略低于相差-0.72 D,两种方法呈正相关(R(21) = 0.94,p 结论):研究结果表明,IOLMaster 700 B-scan 图像分析技术可提供与相差法相似的晶状体表面屈光度估计值。这些结果凸显了 IOLMaster 700 在测量晶状体形状方面的潜力,为未来的研究和临床应用提供了参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement of in vivo lens shapes using IOLMaster 700 B-scan images: Comparison with phakometry.

Purpose: This study compared in vivo crystalline lens shape measurements using B-scan images from the IOLMaster 700 with phakometry.

Methods: Twenty-four young adult participants underwent IOLMaster 700 and phakometry measurements under cycloplegia (1% cyclopentolate). The IOLMaster 700 generated B-scan images along six meridians in 30° increments, which were analysed using custom MATLAB software to determine lens surface radii of curvature. Phakometry measurements were obtained using Purkinje images reflected from the lens surfaces.

Results: The IOLMaster 700 image analysis method yielded a lower mean anterior lens surface spherical equivalent power (+6.20 D) than phakometry (+7.55 D); however, the two measurements were strongly correlated (R(21) = 0.97, p < 0.0001). The astigmatic power vectors (J0 and J45) for the anterior lens surface were significantly higher for the IOLMaster 700 measurements, with only J0 showing a significant moderate positive correlation (R(21) = 0.57, p = 0.005). For the posterior lens surface, the IOLMaster 700 measurements had a higher mean spherical power (+14.28 D) compared to phakometry (+13.70 D); however, a strong positive correlation (R(21) = 0.90, p < 0.0001) was observed. No significant correlations were noted for posterior lens surface astigmatic vectors (J0 and J45). The IOLMaster 700 estimates for the equivalent lens mean spherical power were slightly lower than those for phakometry, with a mean difference of -0.72 D, and both methods were positively correlated (R(21) = 0.94, p < 0.0001).

Conclusions: The findings demonstrate that IOLMaster 700 B-scan image analysis technique provides similar estimates of lens surface powers to phakometry. These results highlight the potential of the IOLMaster 700 to provide measurements of lens shape, informing future research and clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
期刊最新文献
Refractive development II: Modelling normal and myopic eye growth. What intrinsic factors affect the central corneal thickness? The effect of lens and fitting characteristics upon scleral lens centration. Recommended improvements to the statistical guidelines. Exploring the relationship between 24-2 visual field and widefield optical coherence tomography data across healthy, glaucoma suspect and glaucoma eyes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1