一项关于在颅椎骨解剖异常的情况下采用敲击和钻孔技术徒手放置颈椎 C1 C2 螺钉的准确性的机构研究:根据 SGPGI 螺钉准确性标准对 600 多枚螺钉进行评估。

IF 1.4 Q2 OTORHINOLARYNGOLOGY Journal of Craniovertebral Junction and Spine Pub Date : 2024-01-01 Epub Date: 2024-03-13 DOI:10.4103/jcvjs.jcvjs_116_23
Sudhir Bisan Sasapardhi, Pawan Kumar Verma, Arun Kumar Srivastava, Kuntal Kanti Das, Ashutosh Kumar, Priyadarshi Dikshit, Ved Prakash Maurya, Kamlesh Singh Bhaisora, Anant Mehrotra, Awadhesh Kumar Jaiswal, Prabhaker Mishra, Sanjay Behari, Raj Kumar, Harshit Mishra, Kalyani Shahare
{"title":"一项关于在颅椎骨解剖异常的情况下采用敲击和钻孔技术徒手放置颈椎 C1 C2 螺钉的准确性的机构研究:根据 SGPGI 螺钉准确性标准对 600 多枚螺钉进行评估。","authors":"Sudhir Bisan Sasapardhi, Pawan Kumar Verma, Arun Kumar Srivastava, Kuntal Kanti Das, Ashutosh Kumar, Priyadarshi Dikshit, Ved Prakash Maurya, Kamlesh Singh Bhaisora, Anant Mehrotra, Awadhesh Kumar Jaiswal, Prabhaker Mishra, Sanjay Behari, Raj Kumar, Harshit Mishra, Kalyani Shahare","doi":"10.4103/jcvjs.jcvjs_116_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the accuracy of freehand cervical C1 C2 screws placement by knock and drill (K and D) technique in craniovertebral anomalous bony anatomy.</p><p><strong>Materials and methods: </strong>From January 2017 to December 2022, 682 consecutive C1 C2 screws in 215 patients with craniovertebral junction (CVJ) anomalies were enrolled. All patients underwent posterior fixation with K and D technique without any fluoroscopic guidance. The patient's demographic details, clinical details, radiological details, major intraoperative events, and postoperative complications were noted. The screws malposition grades and direction on CT images in the axial and sagittal plane were defined as new per proposed \"SGPGI accuracy criteria.\" All patients had a clinical evaluation at 3-month follow-up.</p><p><strong>Results: </strong>Total 682 C1, C2 screws were placed in 215 patients for CVJ anomalies using K and D technique. The accuracy of screws placement by freehand technique was 84.46% (576/682). So with technique explained the rate of malplacement in simple (16.35%) and complex (15.19%) groups were almost comparable and comparison difference was not significant (<i>P</i> = 0.7005).</p><p><strong>Conclusion: </strong>The freehand technique, as described, is effective in cases of anomalous bony anatomy, and it is mandatory in complex CVJ anomalies. The accuracy of screw placement and VA injury is comparable with major studies. This technique is supposedly cost-effective and less hazardous to both health-care workers and patients.</p>","PeriodicalId":51721,"journal":{"name":"Journal of Craniovertebral Junction and Spine","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11029100/pdf/","citationCount":"0","resultStr":"{\"title\":\"An institutional study on accuracy of freehand cervical C1 C2 screws placement by knock and drill technique in craniovertebral anomalous bony anatomy: An evaluation of more than 600 screws based on SGPGI screw accuracy criteria.\",\"authors\":\"Sudhir Bisan Sasapardhi, Pawan Kumar Verma, Arun Kumar Srivastava, Kuntal Kanti Das, Ashutosh Kumar, Priyadarshi Dikshit, Ved Prakash Maurya, Kamlesh Singh Bhaisora, Anant Mehrotra, Awadhesh Kumar Jaiswal, Prabhaker Mishra, Sanjay Behari, Raj Kumar, Harshit Mishra, Kalyani Shahare\",\"doi\":\"10.4103/jcvjs.jcvjs_116_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the accuracy of freehand cervical C1 C2 screws placement by knock and drill (K and D) technique in craniovertebral anomalous bony anatomy.</p><p><strong>Materials and methods: </strong>From January 2017 to December 2022, 682 consecutive C1 C2 screws in 215 patients with craniovertebral junction (CVJ) anomalies were enrolled. All patients underwent posterior fixation with K and D technique without any fluoroscopic guidance. The patient's demographic details, clinical details, radiological details, major intraoperative events, and postoperative complications were noted. The screws malposition grades and direction on CT images in the axial and sagittal plane were defined as new per proposed \\\"SGPGI accuracy criteria.\\\" All patients had a clinical evaluation at 3-month follow-up.</p><p><strong>Results: </strong>Total 682 C1, C2 screws were placed in 215 patients for CVJ anomalies using K and D technique. The accuracy of screws placement by freehand technique was 84.46% (576/682). So with technique explained the rate of malplacement in simple (16.35%) and complex (15.19%) groups were almost comparable and comparison difference was not significant (<i>P</i> = 0.7005).</p><p><strong>Conclusion: </strong>The freehand technique, as described, is effective in cases of anomalous bony anatomy, and it is mandatory in complex CVJ anomalies. The accuracy of screw placement and VA injury is comparable with major studies. This technique is supposedly cost-effective and less hazardous to both health-care workers and patients.</p>\",\"PeriodicalId\":51721,\"journal\":{\"name\":\"Journal of Craniovertebral Junction and Spine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11029100/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Craniovertebral Junction and Spine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jcvjs.jcvjs_116_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Craniovertebral Junction and Spine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jcvjs.jcvjs_116_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估在颅椎骨解剖异常的情况下,通过敲钻(K and D)技术徒手放置颈椎C1 C2螺钉的准确性:自2017年1月至2022年12月,对215例颅椎交界处(CVJ)异常患者的682枚连续C1 C2螺钉进行了登记。所有患者均在无透视引导的情况下接受了 K 和 D 技术的后路固定。研究人员记录了患者的人口统计学资料、临床资料、放射学资料、术中主要事件和术后并发症。根据提议的 "SGPGI 精确度标准",CT 图像轴向和矢状面上的螺钉错位等级和方向被定义为新的。所有患者均在 3 个月的随访中接受了临床评估:采用 K 和 D 技术为 215 名 CVJ 异常患者植入了 682 枚 C1 和 C2 螺钉。采用徒手技术放置螺钉的准确率为 84.46%(576/682)。因此,根据技术解释,简单组(16.35%)和复杂组(15.19%)的误置率几乎相当,比较差异不显著(P = 0.7005):结论:所描述的徒手技术对于骨性解剖异常的病例是有效的,对于复杂的 CVJ 异常病例则是必须的。螺钉置入的准确性和 VA 损伤与主要研究结果相当。据称,这种技术具有成本效益,对医护人员和患者的危害较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An institutional study on accuracy of freehand cervical C1 C2 screws placement by knock and drill technique in craniovertebral anomalous bony anatomy: An evaluation of more than 600 screws based on SGPGI screw accuracy criteria.

Purpose: To assess the accuracy of freehand cervical C1 C2 screws placement by knock and drill (K and D) technique in craniovertebral anomalous bony anatomy.

Materials and methods: From January 2017 to December 2022, 682 consecutive C1 C2 screws in 215 patients with craniovertebral junction (CVJ) anomalies were enrolled. All patients underwent posterior fixation with K and D technique without any fluoroscopic guidance. The patient's demographic details, clinical details, radiological details, major intraoperative events, and postoperative complications were noted. The screws malposition grades and direction on CT images in the axial and sagittal plane were defined as new per proposed "SGPGI accuracy criteria." All patients had a clinical evaluation at 3-month follow-up.

Results: Total 682 C1, C2 screws were placed in 215 patients for CVJ anomalies using K and D technique. The accuracy of screws placement by freehand technique was 84.46% (576/682). So with technique explained the rate of malplacement in simple (16.35%) and complex (15.19%) groups were almost comparable and comparison difference was not significant (P = 0.7005).

Conclusion: The freehand technique, as described, is effective in cases of anomalous bony anatomy, and it is mandatory in complex CVJ anomalies. The accuracy of screw placement and VA injury is comparable with major studies. This technique is supposedly cost-effective and less hazardous to both health-care workers and patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
9.10%
发文量
57
审稿时长
12 weeks
期刊最新文献
Catastrophic spontaneous spinal epidural hematoma following thrombolysis: An intersection of neurosurgical and cardiological challenges - An institutional experience. Chronic muscle pain and spasm hallmarks of spinal instability. Comparison of postoperative complications and outcomes following primary versus revision discectomy: A national database analysis. Correlation between sagittal morphology of lower lumbar end plate and degenerative changes in patients with lumbar disc herniation. Demographics in the context of health-care delivery for C1 and C2 fractures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1