{"title":"颈部 CT 扫描在非穿透性创伤中检测气胸的灵敏度。","authors":"R Byebwa, E E Nweke, M S Moeng","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The trauma-related pneumothorax is a common intrathoracic injury and can go undetected with detrimental outcomes. Chest computed tomography (CT) investigation in low- to middle-income countries (LMIC) is not always readily available during emergency situations and increased workloads. However, alternative investigations all have limitations in including pneumothoraces. Patients may have trauma indications for CT of the head and neck. The neck CT scan may hold an extra potential advantage in pneumothorax detection. This study aimed to assess its sensitivity in pneumothorax detection in nonpenetrating trauma.</p><p><strong>Methods: </strong>A retrospective study was conducted from 1 January 2016 to 31 December 2021. All adult patients sustaining nonpenetrating injuries, and investigated with chest and neck CT scans were included. The chest CT scan was the gold standard against,which the neck CT scan was compared to determine the accuracy of pneumothorax detection. Stata version 16 was used for descriptive statistical analysis, and a <i>p</i>-value of 0.05 was considered statistically significant.</p><p><strong>Results: </strong>One thousand ninety three were eligible for evaluation; 204 (18.66%) pneumothoraces were detected on chest CT scans, 200 (98.0%) of which were also detected on the neck CT scan, producing a sensitivity of 98.0% (95% CI 95.1-99.5%) and a specificity of 100% (95% CI 99.6-100%). Most pneumothoraces were detected at T1 level (45.09%), followed by T2 (43.62%).</p><p><strong>Conclusion: </strong>The neck CT scan has demonstrated high sensitivity and specificity in pneumothorax detection. Thus, it may be used as an additional tool for those who could not receive or do not need a formal chest CT but have an indication for neck CT scans.</p>","PeriodicalId":51161,"journal":{"name":"South African Journal of Surgery","volume":"62 1","pages":"18-22"},"PeriodicalIF":0.4000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The sensitivity of a neck CT scan in detecting pneumothoraces in nonpenetrating trauma.\",\"authors\":\"R Byebwa, E E Nweke, M S Moeng\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The trauma-related pneumothorax is a common intrathoracic injury and can go undetected with detrimental outcomes. Chest computed tomography (CT) investigation in low- to middle-income countries (LMIC) is not always readily available during emergency situations and increased workloads. However, alternative investigations all have limitations in including pneumothoraces. Patients may have trauma indications for CT of the head and neck. The neck CT scan may hold an extra potential advantage in pneumothorax detection. This study aimed to assess its sensitivity in pneumothorax detection in nonpenetrating trauma.</p><p><strong>Methods: </strong>A retrospective study was conducted from 1 January 2016 to 31 December 2021. All adult patients sustaining nonpenetrating injuries, and investigated with chest and neck CT scans were included. The chest CT scan was the gold standard against,which the neck CT scan was compared to determine the accuracy of pneumothorax detection. Stata version 16 was used for descriptive statistical analysis, and a <i>p</i>-value of 0.05 was considered statistically significant.</p><p><strong>Results: </strong>One thousand ninety three were eligible for evaluation; 204 (18.66%) pneumothoraces were detected on chest CT scans, 200 (98.0%) of which were also detected on the neck CT scan, producing a sensitivity of 98.0% (95% CI 95.1-99.5%) and a specificity of 100% (95% CI 99.6-100%). Most pneumothoraces were detected at T1 level (45.09%), followed by T2 (43.62%).</p><p><strong>Conclusion: </strong>The neck CT scan has demonstrated high sensitivity and specificity in pneumothorax detection. Thus, it may be used as an additional tool for those who could not receive or do not need a formal chest CT but have an indication for neck CT scans.</p>\",\"PeriodicalId\":51161,\"journal\":{\"name\":\"South African Journal of Surgery\",\"volume\":\"62 1\",\"pages\":\"18-22\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"South African Journal of Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"South African Journal of Surgery","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
The sensitivity of a neck CT scan in detecting pneumothoraces in nonpenetrating trauma.
Background: The trauma-related pneumothorax is a common intrathoracic injury and can go undetected with detrimental outcomes. Chest computed tomography (CT) investigation in low- to middle-income countries (LMIC) is not always readily available during emergency situations and increased workloads. However, alternative investigations all have limitations in including pneumothoraces. Patients may have trauma indications for CT of the head and neck. The neck CT scan may hold an extra potential advantage in pneumothorax detection. This study aimed to assess its sensitivity in pneumothorax detection in nonpenetrating trauma.
Methods: A retrospective study was conducted from 1 January 2016 to 31 December 2021. All adult patients sustaining nonpenetrating injuries, and investigated with chest and neck CT scans were included. The chest CT scan was the gold standard against,which the neck CT scan was compared to determine the accuracy of pneumothorax detection. Stata version 16 was used for descriptive statistical analysis, and a p-value of 0.05 was considered statistically significant.
Results: One thousand ninety three were eligible for evaluation; 204 (18.66%) pneumothoraces were detected on chest CT scans, 200 (98.0%) of which were also detected on the neck CT scan, producing a sensitivity of 98.0% (95% CI 95.1-99.5%) and a specificity of 100% (95% CI 99.6-100%). Most pneumothoraces were detected at T1 level (45.09%), followed by T2 (43.62%).
Conclusion: The neck CT scan has demonstrated high sensitivity and specificity in pneumothorax detection. Thus, it may be used as an additional tool for those who could not receive or do not need a formal chest CT but have an indication for neck CT scans.
期刊介绍:
The South African Journal of Surgery (SAJS) is a quarterly, general surgical journal. It carries research articles and letters, editorials, clinical practice and other surgical articles and personal opinion, South African health-related news, obituaries and general correspondence.