{"title":"在重复 CT 采集中尽量减少肺部病变形态学放射组学特征可检测差异的方案选择形式。","authors":"Mojtaba Zarei, Ehsan Abadi, Liesbeth Vancoillie, Ehsan Samei","doi":"10.1117/1.JMI.11.2.025501","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The accuracy of morphological radiomic features (MRFs) can be affected by various acquisition settings and imaging conditions. To ensure that clinically irrelevant changes do not reduce sensitivity to capture the radiomics changes between successive acquisitions, it is essential to determine the optimal imaging systems and protocols to use.</p><p><strong>Purpose: </strong>The main goal of our study was to optimize CT protocols and minimize the minimum detectable difference (MDD) in successive acquisitions of MRFs.</p><p><strong>Method: </strong>MDDs were derived based on the previous research involving 15 realizations of nodule models at two different sizes. Our study involved simulations of two consecutive acquisitions using 297 different imaging conditions, representing variations in scanners' reconstruction kernels, dose levels, and slice thicknesses. Parametric polynomial models were developed to establish correlations between imaging system characteristics, lesion size, and MDDs. Additionally, polynomial models were used to model the correlation of the imaging system parameters. Optimization problems were formulated for each MRF to minimize the approximated function. Feature importance was determined for each MRF through permutation feature analysis. The proposed method was compared to the recommended guidelines by the quantitative imaging biomarkers alliance (QIBA).</p><p><strong>Results: </strong>The feature importance analysis showed that lesion size is the most influential parameter to estimate the MDDs in most of the MRFs. Our study revealed that thinner slices and higher doses had a measurable impact on reducing the MDDs. Higher spatial resolution and lower noise magnitude were identified as the most suitable or noninferior acquisition settings. Compared to QIBA, the proposed protocol selection guideline demonstrated a reduced coefficient of variation, with values decreasing from 1.49 to 1.11 for large lesions and from 1.68 to 1.12 for small lesions.</p><p><strong>Conclusion: </strong>The protocol optimization framework provides means to assess and optimize protocols to minimize the MDD to increase the sensitivity of the measurements in lung cancer screening.</p>","PeriodicalId":47707,"journal":{"name":"Journal of Medical Imaging","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11047768/pdf/","citationCount":"0","resultStr":"{\"title\":\"Protocol selection formalism for minimizing detectable differences in morphological radiomics features of lung lesions in repeated CT acquisitions.\",\"authors\":\"Mojtaba Zarei, Ehsan Abadi, Liesbeth Vancoillie, Ehsan Samei\",\"doi\":\"10.1117/1.JMI.11.2.025501\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The accuracy of morphological radiomic features (MRFs) can be affected by various acquisition settings and imaging conditions. To ensure that clinically irrelevant changes do not reduce sensitivity to capture the radiomics changes between successive acquisitions, it is essential to determine the optimal imaging systems and protocols to use.</p><p><strong>Purpose: </strong>The main goal of our study was to optimize CT protocols and minimize the minimum detectable difference (MDD) in successive acquisitions of MRFs.</p><p><strong>Method: </strong>MDDs were derived based on the previous research involving 15 realizations of nodule models at two different sizes. Our study involved simulations of two consecutive acquisitions using 297 different imaging conditions, representing variations in scanners' reconstruction kernels, dose levels, and slice thicknesses. Parametric polynomial models were developed to establish correlations between imaging system characteristics, lesion size, and MDDs. Additionally, polynomial models were used to model the correlation of the imaging system parameters. Optimization problems were formulated for each MRF to minimize the approximated function. Feature importance was determined for each MRF through permutation feature analysis. The proposed method was compared to the recommended guidelines by the quantitative imaging biomarkers alliance (QIBA).</p><p><strong>Results: </strong>The feature importance analysis showed that lesion size is the most influential parameter to estimate the MDDs in most of the MRFs. Our study revealed that thinner slices and higher doses had a measurable impact on reducing the MDDs. Higher spatial resolution and lower noise magnitude were identified as the most suitable or noninferior acquisition settings. Compared to QIBA, the proposed protocol selection guideline demonstrated a reduced coefficient of variation, with values decreasing from 1.49 to 1.11 for large lesions and from 1.68 to 1.12 for small lesions.</p><p><strong>Conclusion: </strong>The protocol optimization framework provides means to assess and optimize protocols to minimize the MDD to increase the sensitivity of the measurements in lung cancer screening.</p>\",\"PeriodicalId\":47707,\"journal\":{\"name\":\"Journal of Medical Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11047768/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JMI.11.2.025501\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JMI.11.2.025501","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Protocol selection formalism for minimizing detectable differences in morphological radiomics features of lung lesions in repeated CT acquisitions.
Background: The accuracy of morphological radiomic features (MRFs) can be affected by various acquisition settings and imaging conditions. To ensure that clinically irrelevant changes do not reduce sensitivity to capture the radiomics changes between successive acquisitions, it is essential to determine the optimal imaging systems and protocols to use.
Purpose: The main goal of our study was to optimize CT protocols and minimize the minimum detectable difference (MDD) in successive acquisitions of MRFs.
Method: MDDs were derived based on the previous research involving 15 realizations of nodule models at two different sizes. Our study involved simulations of two consecutive acquisitions using 297 different imaging conditions, representing variations in scanners' reconstruction kernels, dose levels, and slice thicknesses. Parametric polynomial models were developed to establish correlations between imaging system characteristics, lesion size, and MDDs. Additionally, polynomial models were used to model the correlation of the imaging system parameters. Optimization problems were formulated for each MRF to minimize the approximated function. Feature importance was determined for each MRF through permutation feature analysis. The proposed method was compared to the recommended guidelines by the quantitative imaging biomarkers alliance (QIBA).
Results: The feature importance analysis showed that lesion size is the most influential parameter to estimate the MDDs in most of the MRFs. Our study revealed that thinner slices and higher doses had a measurable impact on reducing the MDDs. Higher spatial resolution and lower noise magnitude were identified as the most suitable or noninferior acquisition settings. Compared to QIBA, the proposed protocol selection guideline demonstrated a reduced coefficient of variation, with values decreasing from 1.49 to 1.11 for large lesions and from 1.68 to 1.12 for small lesions.
Conclusion: The protocol optimization framework provides means to assess and optimize protocols to minimize the MDD to increase the sensitivity of the measurements in lung cancer screening.
期刊介绍:
JMI covers fundamental and translational research, as well as applications, focused on medical imaging, which continue to yield physical and biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal. The scope of JMI includes: Imaging physics, Tomographic reconstruction algorithms (such as those in CT and MRI), Image processing and deep learning, Computer-aided diagnosis and quantitative image analysis, Visualization and modeling, Picture archiving and communications systems (PACS), Image perception and observer performance, Technology assessment, Ultrasonic imaging, Image-guided procedures, Digital pathology, Biomedical applications of biomedical imaging. JMI allows for the peer-reviewed communication and archiving of scientific developments, translational and clinical applications, reviews, and recommendations for the field.