支气管内超声(EBUS)在肺癌分期中的准确性--EBUS分期与术后病理结节分期的比较。

IF 1.3 Q4 RESPIRATORY SYSTEM Lung India Pub Date : 2024-03-01 Epub Date: 2024-02-27 DOI:10.4103/lungindia.lungindia_449_23
Eshita Shah, N Sankara Raman, Manish K Aggarwal, Amit Jain, Arushi Chokhani, Avinash Murugan, Rajiv Goyal, Laengmawia Darlong, Ullas Batra
{"title":"支气管内超声(EBUS)在肺癌分期中的准确性--EBUS分期与术后病理结节分期的比较。","authors":"Eshita Shah, N Sankara Raman, Manish K Aggarwal, Amit Jain, Arushi Chokhani, Avinash Murugan, Rajiv Goyal, Laengmawia Darlong, Ullas Batra","doi":"10.4103/lungindia.lungindia_449_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Endobronchial ultrasound-guided transbronchial fine-needle aspiration (EBUS-TBNA) has replaced mediastinoscopy as the preferred investigation for evaluating mediastinum in staging lung cancer. There is little evidence of mediastinal staging by EBUS-TBNA from India.</p><p><strong>Objectives: </strong>To study endobronchial ultrasound's diagnostic accuracy in staging lung cancer.</p><p><strong>Methodology: </strong>We retrospectively analysed patients operated on for lung cancer where EBUS was performed preoperatively for mediastinal staging. We compared the histological findings obtained from different mediastinal lymph nodes (LNs) by EBUS-TBNA with the pathology of the same LNs obtained after surgical dissection as the reference standard.</p><p><strong>Results: </strong>Seventy-six patients underwent curative surgery for lung cancer. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of EBUS-TBNA in predicting mediastinal metastasis were 93.9%, 40%, 99%, 80% and 94.6%, respectively. Of the 115 LNs sampled, EBUS-TBNA was false negative in six nodes, resulting in an up-staging of six patients.</p><p><strong>Conclusions: </strong>EBUS-TBNA has a high diagnostic accuracy for lung cancer staging.</p>","PeriodicalId":47462,"journal":{"name":"Lung India","volume":"41 2","pages":"93-97"},"PeriodicalIF":1.3000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10959321/pdf/","citationCount":"0","resultStr":"{\"title\":\"Accuracy of endobronchial ultrasound (EBUS) in the staging of lung cancer - A comparison of staging EBUS with postoperative pathological nodal staging.\",\"authors\":\"Eshita Shah, N Sankara Raman, Manish K Aggarwal, Amit Jain, Arushi Chokhani, Avinash Murugan, Rajiv Goyal, Laengmawia Darlong, Ullas Batra\",\"doi\":\"10.4103/lungindia.lungindia_449_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Endobronchial ultrasound-guided transbronchial fine-needle aspiration (EBUS-TBNA) has replaced mediastinoscopy as the preferred investigation for evaluating mediastinum in staging lung cancer. There is little evidence of mediastinal staging by EBUS-TBNA from India.</p><p><strong>Objectives: </strong>To study endobronchial ultrasound's diagnostic accuracy in staging lung cancer.</p><p><strong>Methodology: </strong>We retrospectively analysed patients operated on for lung cancer where EBUS was performed preoperatively for mediastinal staging. We compared the histological findings obtained from different mediastinal lymph nodes (LNs) by EBUS-TBNA with the pathology of the same LNs obtained after surgical dissection as the reference standard.</p><p><strong>Results: </strong>Seventy-six patients underwent curative surgery for lung cancer. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of EBUS-TBNA in predicting mediastinal metastasis were 93.9%, 40%, 99%, 80% and 94.6%, respectively. Of the 115 LNs sampled, EBUS-TBNA was false negative in six nodes, resulting in an up-staging of six patients.</p><p><strong>Conclusions: </strong>EBUS-TBNA has a high diagnostic accuracy for lung cancer staging.</p>\",\"PeriodicalId\":47462,\"journal\":{\"name\":\"Lung India\",\"volume\":\"41 2\",\"pages\":\"93-97\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10959321/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lung India\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/lungindia.lungindia_449_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lung India","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/lungindia.lungindia_449_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/27 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

背景:支气管内超声引导下经支气管细针穿刺术(EBUS-TBNA)已取代纵隔镜检查,成为评估肺癌纵隔分期的首选检查方法。在印度,通过 EBUS-TBNA 进行纵隔分期的证据很少:研究支气管内超声对肺癌分期的诊断准确性:我们回顾性地分析了接受肺癌手术的患者,这些患者在术前进行了EBUS纵隔分期。我们将通过 EBUS-TBNA 获得的不同纵隔淋巴结(LN)的组织学结果与手术切除后获得的相同 LN 的病理学结果作为参考标准进行了比较:76名肺癌患者接受了根治性手术。EBUS-TBNA 预测纵隔转移的诊断准确率、敏感性、特异性、阳性预测值和阴性预测值分别为 93.9%、40%、99%、80% 和 94.6%。在取样的115个纵隔中,EBUS-TBNA对6个结节的预测为假阴性,导致6名患者向上分期:结论:EBUS-TBNA 对肺癌分期的诊断准确率很高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy of endobronchial ultrasound (EBUS) in the staging of lung cancer - A comparison of staging EBUS with postoperative pathological nodal staging.

Background: Endobronchial ultrasound-guided transbronchial fine-needle aspiration (EBUS-TBNA) has replaced mediastinoscopy as the preferred investigation for evaluating mediastinum in staging lung cancer. There is little evidence of mediastinal staging by EBUS-TBNA from India.

Objectives: To study endobronchial ultrasound's diagnostic accuracy in staging lung cancer.

Methodology: We retrospectively analysed patients operated on for lung cancer where EBUS was performed preoperatively for mediastinal staging. We compared the histological findings obtained from different mediastinal lymph nodes (LNs) by EBUS-TBNA with the pathology of the same LNs obtained after surgical dissection as the reference standard.

Results: Seventy-six patients underwent curative surgery for lung cancer. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of EBUS-TBNA in predicting mediastinal metastasis were 93.9%, 40%, 99%, 80% and 94.6%, respectively. Of the 115 LNs sampled, EBUS-TBNA was false negative in six nodes, resulting in an up-staging of six patients.

Conclusions: EBUS-TBNA has a high diagnostic accuracy for lung cancer staging.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lung India
Lung India RESPIRATORY SYSTEM-
CiteScore
2.30
自引率
12.50%
发文量
114
审稿时长
37 weeks
期刊最新文献
Comparing standard treatment of moderate to severe obstructive sleep apnoea to add-on acetazolamide treatment: An open-label randomised controlled trial. COPD in females- Seeing through the smoke. Diagnostic value of monocyte chemoattractant protein-1 (MCP-1) and lactate dehydrogenase (LDH) in malignant pleural effusion: A cross-sectional study. Distribution of vaccine-preventable respiratory viral infections in 2023: Insights from a Tertiary Care Center in Southern India. Endobronchial stenting in a rare case of severe necrotic tracheal mucormycosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1