Muhammed Köroğlu, Mustafa Karakaplan, Emre Ergen, Mehmet Eren, Abdulkarim Alyousef, Hüseyin Utku Özdeş, Okan Aslantürk
{"title":"肩胛骨截骨术张力带固定的罕见并发症:K线远端移位。","authors":"Muhammed Köroğlu, Mustafa Karakaplan, Emre Ergen, Mehmet Eren, Abdulkarim Alyousef, Hüseyin Utku Özdeş, Okan Aslantürk","doi":"10.52312/jdrs.2024.1662","DOIUrl":null,"url":null,"abstract":"<p><p>Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.</p>","PeriodicalId":73560,"journal":{"name":"Joint diseases and related surgery","volume":"35 2","pages":"439-442"},"PeriodicalIF":1.9000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11128946/pdf/","citationCount":"0","resultStr":"{\"title\":\"A rare complication of tension band fixation of olecranon osteotomy: Distal migration of K-wire.\",\"authors\":\"Muhammed Köroğlu, Mustafa Karakaplan, Emre Ergen, Mehmet Eren, Abdulkarim Alyousef, Hüseyin Utku Özdeş, Okan Aslantürk\",\"doi\":\"10.52312/jdrs.2024.1662\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.</p>\",\"PeriodicalId\":73560,\"journal\":{\"name\":\"Joint diseases and related surgery\",\"volume\":\"35 2\",\"pages\":\"439-442\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11128946/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Joint diseases and related surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52312/jdrs.2024.1662\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Joint diseases and related surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52312/jdrs.2024.1662","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
张力带接线(TBW)是固定肩胛骨截骨最常用的固定技术之一。硬件突出是 TBW 最常见的并发症。然而,TBW固定治疗肩胛骨截骨术后Kirschner(K)线远端移位的情况尚未见报道。在本病例报告中,我们介绍了一名 46 岁男性患者在初次手术 9 个月后发现的 K 线远端移位。该患者因肱骨远端关节内骨折接受了手术,采用的是肩胛骨截骨术。截骨后采用 TBW 固定。患者错过了例行复诊,术后九个月因肘部皮肤过敏到门诊就诊。经放射学检查,发现一根 K 线远端移位。通过手术取出了 K 线,未出现任何并发症。医生应了解 TBW 可能出现的并发症,并在骨折愈合后取出固定物,以避免意外并发症的发生。
A rare complication of tension band fixation of olecranon osteotomy: Distal migration of K-wire.
Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.